Electrical Connections
Power cord:
●
The electric power supply requirement for this water heater is 120 VAC/60HZ,
2 Amps.
●
The water heater comes with a three (3) pin power supply cord. Use only a
power outlet with a ground terminal.
●
The installation of an electric leakage breaker is recommended. (GFCI)
●
Keep any excess of the power supply cord on the outside of the water heater.
●
If local codes require hardwiring, see instructions for “Hardwiring the Electrical
Connections”.
WARNING: Shock hazard line voltage is present. Before servicing the
water heater, turn off the electrical power to the water heater at the main
disconnect or circuit breaker. Failure to do so could result in severe
personal injury or death.
Hardwiring the ele ctrical connections:
●
Wiring should be carried out by a qualified electrician in accordance with local
codes.
●
The water heater requires 120 VAC/60Hz and should be properly grounded.
●
DO NOT connect grounding wire to water pipes, gas pipes, telephone cables,
lightning conductor circuits and to grounding circuit of other equipment that
carry a ground-fault interrupter.
●
An ON/OFF switch must be provided and installed for the incoming 120VAC
power.
●
Wire the water heater exactly as shown below. A wiring diagram is also found
inside of the cover panel.
●
A green screw is provided in the junction box for grounding connection.
●
Connect the live wire to black leg wire and the neutral wire to the white neutral
wire.
CAUTION: Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous operation. Verify
correct operation after servicing.