● The vent pipe should be installed with a flame retardant wall thimble. Owner
must refer to vent manufacturer’s instructions and specifications. Z-Flex
information can be found at www.novaflex.com, please refer to page 48 for
additional links. Installation guidelines for venting provided by NovaFlex, who is
solely responsible for venting installation accuracy.
●
The power socket connecting the water heater should be grounded properly
with a GFCI circuit protector.
●
The water heater should not be located in an area where leakage of the heat
exchanger or connections will result in damage to the area adjacent to it or to
lower floors of the structure. When such areas cannot be avoided it is
recommended that a suitable catch pan, adequately drained, must be installed
under the water heater. The pan must not restrict combustion airflow.
●
The water heater should be installed as close as practical to the vent
termination to minimize vent length and the number of elbows required for
venting.
●
A gas fired water heater or any other appliance should not be installed in a
space where liquids which give off flammable vapors are to be used or stored.
Such liquids include gasoline, LP gas(butane or propane), paint or adhesives
and their thinners, solvents or removers.
●
Raising the water heater will reduce, BUT NOT eliminate the possibility of
lighting the vapor of any flammable liquids which may be improperly stored or
accidentally spilled .
●
If the water heater is installed in a garage, it should be installed so that the
direct ignition system and main burner are no less than 18 inches above the
garage floor.
●
Hot and cold water lines should be insulated to conserve water and energy.
●
The water heater must be located so it is not subject to physical damage, for
example, by moving vehicles, area flooding, etc.
●
The water heater should be installed with the proper venting materials and
termination suitable for Category III venting. Failure to install and properly vent
the water heater to the outdoors as outlined in the Venting Section of this
manual can result in unsafe operation. Owner must refer to vent
manufacturer’s instructions and specifications. Z-Flex information can be found
at www.novaflex.com, please refer to page 48 for additional links.
●
For other than a direct vent appliance, the appliance must be located as close
as practicable to a chimney or gas vent.
●
DO NOT install water heater where subject to vibrations. or on the road use
●
DO NOT install the water heater in Recreational Vehicles, Mobile Homes,
Boats and other Watercraft.