Installing the CA686M Tankless Water Heater
Indoor location
●
Installation distances may vary by local code. It is the installer’s responsibility
to verify installation requirements.
●
Make sure before installation that the gas type you will use is the same type on
the data plate.
●
The water heater should be installed by professionals. Improper installation
may cause failure or dangerous conditions such as gas leaking or explosion.
●
Water Heater cannot be installed in an UN-VENTED bathroom, bedroom,
basement, living room, closet, outdoor, stairway or an exit area. If installed in
an exit area, it must be at least 16.5 ft. or more away from the exit.
●
Vent pipe should extend from the wall at least 2”. The terminal must be at least
1.64 ft. away from obstruction, and must be well vented.
●
Vent pipe should slope 3° downward, to avoid condensing water and protect
from rain entering.
●
Vent pipe should avoid direct, strong wind because the downdraft will cause
malfunction.
●
The water heater should be installed far from any blockage, and with plenty of
space for installation and maintenance. Adequate clearances for servicing must
be provided.
●
The water heater should not be installed in the same room with a gas stove.
●
When determining the floor clearance, a clearance of 6 inches must be
maintained between the vent pipe and combustible material. A side wall
clearance of 6 inches and a top clearance of 12 inches must be maintained.
●
The vent pipe can be up to 32 ft. in length with one elbow.