Line
Example line output
21
Features A
Description of the line sections
Section
Description
A
List of features enabled
Line
Example line output
22
Flags 0000 0000 0000
Description of the most significant alarm word (left side, bits going left to right). Each alarm
word is a hexadecimal sum of all the error bits.
Bit
Description
8000 XXXX XXXX
Units.
feet
=
0,
met
re
s
=
8
4000 XXXX XXXX
Reserved for future use
2000 XXXX XXXX
Reserved for future use
1000 XXXX XXXX
Reserved for future use
0800 XXXX XXXX
DSP clock out of specification
0400 XXXX XXXX
Laser shut down due to operating temperature out of range
0200 XXXX XXXX
The lead acid battery voltage is reading low
0100 XXXX XXXX
Mains supply has failed (requires a PSU to be present)
0080 XXXX XXXX
The external heater blower assembly temperature is out of bounds
0040 XXXX XXXX
External heater blower failure
0020 XXXX XXXX
The PSUs internal temperature is high
0010 XXXX XXXX
PSU OS has failed its signature check
0008 XXXX XXXX
No communications between DSP and PSU
0004 XXXX XXXX
Photo diode and Laser windows are dirty. This can only be set if the
laser is on
0002 XXXX XXXX
Tilt beyond limit set by user, default 45 degrees
0001 XXXX XXXX
No communications between DSP and inclinometer board