Table 5-1: Summary of the terminal mode commands available
Command
Parameter/
parameter block
Description
required
Stratocumulus cloud layer between 250 m to 2500 m
without holes, precipitation or reduced visibility and
has been stable for at least 10 minutes prior to running
this command. See
(p. 56) for more information.
SERIAL
Mode
Baud
Bits_Parity
Delay
Set or read the serial port.
Mode
= 0, RS-232, full duplex (default)
Mode
= 1, RS-232, half duplex
Mode
= 2, RS-485, full duplex
Mode
= 3, RS-485, half duplex
Mode
= 4, reserved
Mode
= 5, RS-422, full duplex
Baud
= 0, 300 baud
Baud
= 1, 600 baud
Baud
= 2, 1200 baud
Baud
= 3, 2400 baud
Baud
= 4, 4800 baud
Baud
= 5, 9600 baud
Baud
= 6, 19200 baud
Baud
= 7, 38400 baud
Baud
= 8, 57600 baud
Baud
= 9, 76800 baud
Baud
= 10, 115200 baud (default)
Bits_Parity
= 0, 8 bits, no parity, 1 stop bit
(default)
Bits_Parit
y = 1, 7 bits, even parity, 1 stop bit
Bits_Parity
= 2, 7 bits, odd parity, 1 stop bit
Delay
= delay time, in milliseconds, before
SkyVUE™8 (CS136) LIDAR Ceilometer