background image

Oilless Compressors

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. 
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or 
property damage! Retain instructions for future reference.

Description 

Portable oilless air compressors are for 
home and workshop use. Cleaning or 
replacement of the inlet filter on all 
models and draining moisture from the 
air receivers are required maintenance. 

Safety Guidelines

This manual contains information that is 
very important to know and understand. 
This information is provided for SAFETY 
and to PREVENT EQUIPMENT PROBLEMS. 
To help recognize this information, 
observe the following symbols. 

 

Danger indicates  

  an imminently 

hazardous situation which, if not avoided, 
will result in death or serious injury.
 

warning indicates  

  a potentially 

hazardous situation which, if not avoided, 
coulD result in death or serious injury.
 

caution indicates a  

  potentially 

hazardous situation which, if not avoided, 
MAY result in minor or moderate injury.
 

Notice indicates  

  important 

information, that if not followed, MAY 
cause damage to equipment.

Unpacking

When unpacking unit, inspect carefully 
for any damage that may have occurred 
during transit. 

Make sure any loose 

fittings, bolts, etc., are tightened before 
putting unit into service. In case of 
questions, damaged or missing parts, 
please call 1-800-543-6400 for customer 
assistance. Have the serial number, 
model number, and part

s list (with 

missing parts circled) before calling.

  Operating Instructions    

HU3501

Breathable Air warning

This compressor/pump is not 
equipped and should not be 
used “as is” to supply breathing 
quality air. For any application of 

air for human consumption, the 

air compressor/pump will need 
to be fitted with suitable in-line 
safety and alarm equipment. 
This additional equipment is 

necessary to properly filter 
and purify the air to meet 
minimal specifications for Grade 
D breathing  as described in 

Compressed Gas Association 
Commodity Specification G 7.1 
- 1966, OSHA 29 CFR 1910. 134, 
and/or Canadian Standards 
Associations (CSA).

DISCLAIMER OF WARRANTIES
In the event the compressor is 

used for the purpose of breathing 
air application and proper in-line 
safety and alarm equipment is 
not simultaneously used, existing 
warranties shall be voided, and 
Campbell Hausfeld disclaims any 

liability whatsoever for any loss, 
personal injury or damage.

General Safety

CALIFORNIA PROPOSITION 65

 

 This product or 

   its power cord may 

contain chemicals, including lead, known 
to the State of california to cause cancer 
and birth defects or other reproductive 
harm. wash hands after handling.
 

You can

  create 

dust when you cut, sand, 
drill or grind materials such 
as wood, paint, metal, 
concrete, cement, or other 
masonry. This dust often contains 
chemicals known to cause cancer, birth 
defects, or other reproductive harm. 
wear protective gear.

IN630800AV 5/09

GENERAL SAFETY INFORMATION

Air compressors are utilized in a variety 
of air system applications. Because air 
compressors and other components 
(material pump, spray gun, filters, 
lubrications, hoses, etc.) used make up 
a high pressure pumping system, the 
following safety precautions should be 
observed at all times. Only persons well 
acquainted with these rules of safe 
operation should be allowed to use the 
air compressor.

 

 All electrical work  

   should be done by a 

qualified (licensed or certified) 
electrician. on a properly wired circuit, 
the black wires supply a voltage 
potential even when the unit is off.

© 2009 Campbell Hausfeld/Scott Fetzer

For parts, product & service information

visit 

www.chpower.com

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

See Warranty on page 8 for important information about commercial use of this product.

Record the Model No., Serial No. and 

date of purchase located on the base 

below the pump in the space below.
Model No. 

____________________

Serial No. 

____________________

Date of purchase _________________

Retain these numbers for future 

reference.

STOP!

DO NOT RETURN  
THE PRODUCT TO  
THE RETAILER!

Summary of Contents for HU3501

Page 1: ...eet minimal specifications for Grade D breathing as described in Compressed Gas Association Commodity Specification G 7 1 1966 OSHA 29 CFR 1910 134 and or Canadian Standards Associations CSA DISCLAIME...

Page 2: ...t and controls can cause electrical arcs that will ignite a flammable gas or vapor Never operate or repair the unit near a flammable gas or vapor Never store flammable liquids or gases in the vicinity...

Page 3: ...ventilated area so that compressor may be properly cooled 3 Compressor should be located where it can be directly plugged into an outlet but if this is not possible an extension cord may be used It sh...

Page 4: ...ally when tank pressure reaches the maximum preset pressure In the Off position the compressor will not operate This switch should be in the Off position when connecting or disconnecting the power cor...

Page 5: ...ached to regulator indicates air pressure going to hose and any tool attached to end of hose Gauge attached to pressure switch indicates air pressure in tank Maintenance Release all pressure and disco...

Page 6: ...becomes overheated If thermal overload protector shuts motor off frequently look for the following causes 1 Low voltage 2 Wrong gauge wire or length of extension cord 3 Clogged air filter 4 Lack of p...

Page 7: ...eter 2 Check gauge chart under Operation for proper gauge wire and cord length 3 Replace motor 4 Replace or repair 1 Check for proper fuse use time delay fuse Disconnect other electrical appliances fr...

Page 8: ...ited warranty The Purchaser must comply with the warranty given by the engine manufacturer which is supplied with the product G Additional items not covered under this warranty 1 All Compressors a Any...

Page 9: ...r la respiration Grade D d crit dans le Compressed Gas Association Commodity Specification G 7 1 1966 OSHA 29 CFR 1910 134 et ou Canadian Standards Associations CSA D N GATION DES GARANTIES Si le comp...

Page 10: ...de ne pas toucher l xt rieur du moteur car il peut tre assez chaud pour causer des blessures 15 Prot ger le c ble lectrique contre les objets pointus 16 Nettoyer l quipement lectrique ou lectronique...

Page 11: ...38 C 100 F Un espace libre minimum de 45 7 centim tres 18 po entre le compresseur et un mur est exig pour viter le stoppage d air par des objets Ne pas situer la prise d air du compresseur pr s de la...

Page 12: ...ntes et v rifier que ces rallonges conviennent la fiche du produit V rifier que la rallonge n est pas endommag e En utilisant une rallonge s assurer d en utiliser une suffisamment lourde pour transpor...

Page 13: ...te automatiquement Si le compresseur reste en position ON marche et si l air sort compl tement du r servoir en utilisant un mandrin de pneu un outil etc alors le compresseur red marrera automatiqueme...

Page 14: ...it 14 Fr Compresseurs D Air Portatifs l extr mit du r servoir REMARQUE La coupe de vidange doit tre vid e r guli rement Ne retirez pas le bouchon de vidange le r servoir tant sous pression 4 Mettre le...

Page 15: ...ent pour le calibre de fil et la taille de cordon prolongateur corrects 3 Remplacer le moteur 4 Remplacer ou r parer 1 V rifier le type de fusible utiliser un fusible retardement D brancher les autres...

Page 16: ...est fournie avec le produit G Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Tous les Compresseurs a Toutes pi ces d tach es endommag es pendant l exp dition n importe quelle...

Page 17: ...1 1966 de la Asociaci n de Aire Comprimido Igualmente deber cumplir los requisitos establecidos por el Articulo 29 CFR 1910 134 de la Organizaci n norteamericana OSHA y o la Canadian Standards Associa...

Page 18: ...s aislantes para evitar electrocutamiento Tenga cuidado al tocar la parte externa del motor encendido ste podr a estar lmuy caliente y ocasionarle heridas 15 Evite que el cord n el ctrico tenga contac...

Page 19: ...s ruedas puedan usarse para mover la unidad El juego de ensamble del mango incluye 1 mango 2 pernos 1 Inserte los extremos del mango en los soportes en forma de tubo en el tanque 2 Alinee los agujeros...

Page 20: ...cto est dise ado para funcionar en un circuito con una carga nominal de 120 v y tiene un enchufe de conexi n a tierra similar al enchufe ilustrado en la Figura 4 Conecte el producto nicamente a un tom...

Page 21: ...vula est ubicada en el lado del tanque sela para drenar la humedad del tanque diaria mente para evitar que el tanque se oxide Drene el tanque diariamente Reduzca la presi n del tanque a menos de 0 69...

Page 22: ...o 1 Chequee el compresor a ver si tiene alg n problema visible especialmente chequee el filtro de aire para cerciorarse de que est limpio 2 Hale el anillo de la v lvula de seguridad y deje que calce e...

Page 23: ...n de extensi n adecuado vea la secci n CORDONES DE EXTENSION p gina 15 2 Est conectado Chequee el fusible cortacircuito o protector de sobrecarga del motorfuse breaker or motor overload 3 Reemplace e...

Page 24: ...a otorgada por el fabricante del motor de gasolina que se suministra con el producto G Art culos adicionales no cubiertos bajo esta garant a 1 Todos los Compresores a Cualquier componente da ado dura...

Reviews: