 WARNING HOSE IS A TRIP HAZARD

•  Always close LP tank valve and remove coupling nut before 

moving LP tank form specified operating position. 

•  NEVER store a spare LP tank under or near appliance or in 

enclosed areas. NEVER fill the cylinder beyond 80% full. An 
overfilled spare LP tank is hazardous due to possible gas 
released from the safety relief valve. Failure to follow these 
instructions exactly could cause a fire resulting in death or 
serious injury.

•  If you see, smell, or hear escaping gas, immediately get away 

from the LP tank/appliance and call your fire department.

•  All spare LP tanks must have safety caps installed on the LP 

tank outlet

LP Tank Removal, Transport and Storage

•  Turn OFF all control knobs and LP tank valve. Turn coupling 

nut counterclockwise by hand only – do not use tools to 
disconnect. Install safety cap onto LP tank valve. Always use 
cap and strap supplied with valve. Failure to use safety cap as 
directed may result in serious personal injury and/or property 
damage.

•  A disconnected LP tank in 

storage or being transported 
must have a safety cap 
installed (as shown). 
Refillable LP-Gas cylinders 
must be stored outdoors in 
a well ventilated space, out 
of the reach of children, and must not be stored in a building, 
garage or any other enclosed area. Never leave an LP tank 
inside a vehicle, which may become overheated by the sun. 

•  Do not store LP tanks in an area where children play. 
•  Storage of an appliance indoors is permissible only if the 

cylinder is disconnected and removed from the appliance.

•  When the refillable LP-gas supply cylinder is not disconnected 

from the stove, the stove and cylinder must be stored outdoors, 
in a well ventilated space, out of the reach of children, and 
must not be stored in a building, garage or any other enclosed 
areas.

LP Tank

The LP tank used with your appliance must meet the following 
requirements:
•  Purchase LP tanks only with these required measurements: 

12" (30.5cm) (diameter) x 18" (45.7cm) (tall) with 20 lb. (9 
kg.) capacity maximum. 

•  Be constructed and marked in accordance with specifications 

for LP tank of the U.S. Department of Transportation (DOT) or 
the National Standard of Canada, CAN/CSA-B339, Cylinders, 
Spheres and Tubes for the Transportation of Dangerous Goods.

•  The refillable propane cylinder used with this appliance must 

include a collar to protect the cylinder valve.

LP tank valve must have: 

•  Type 1 outlet compatible with 

regulator or appliance. 

•  Safety relief valve.
•  UL listed Overfill Protection Device 

(OPD). This OPD safety feature is 
identified by a unique triangular 
hand wheel. Use only tanks 
equipped with this type of valve. 
LP tank must be arranged for vapor withdrawal.

LP (Liquefied Petroleum Gas)

•  LP gas is non-toxic, odorless and colorless when produced. For 

your safety, LP gas has been given an odor (similar to rotten 
cabbage) so that it can be smelled.

•  LP gas is highly flammable and may ignite unexpectedly when 

mixed with air.

LP Tank Filling

•  Use only licensed and experienced dealers.
•  LP dealer must purge tanks before filling.
•  Dealer should NEVER fill LP tank more than 80% of LP tank 

volume. Volume of propane in tanks will vary by temperature.

•  A frosty regulator indicates gas overfill. Immediately close LP 

tank valve and call local LP gas dealer for assistance.

•  DO NOT release liquid propane (LP) gas into the atmosphere. 

This is a hazardous practice.

•  To remove gas from LP tank, contact an LP dealer or call a 

local fire department for assistance. Check the telephone 
directory under “Gas companies” for nearest certified LP 
dealers.

LP Tank Exchange

•  Many retailers that sell appliances offer you the option of 

replacing your empty LP tanks through an exchange service. Use 
only those reputable exchange companies that inspect, precision 
fill, test and certify their cylinders. Exchange your tank only for 
an OPD safety feature-equipped tank as described in the “LP 
Tank” section of this manual.

•  Always keep new and exchanged LP tanks in upright position 

during use, transit or storage.

 •  Leak test new and exchanged LP tanks BEFORE connecting to 

appliance.

 WARNING

 Appliance must be leak checked outdoors in well-ventilated 
area, away from ignition sources such as gas fired or 
electrical appliances. During leak test, keep appliance away 
from open flames or sparks.

LP Tank Leak Test

For your Safety
•  Leak test must be repeated each time LP tank is exchanged 

or refilled. 

• Do not smoke during leak test.
•  Do not use an open flame to check for gas leaks.
•  Appliance must be leak checked outdoors in well-ventilated 

OPD

 Hand 

Wheel

safety cap

Summary of Contents for COVEND

Page 1: ...WARNING INSTRUCTION BOOKLET MODEL COVEND DELUXE OUTDOOR OVEN...

Page 2: ...Take care the openings at side and rear of the appliance are not obstructed or that air flow is restricted by placing items or other appliances close to or adjacent to openings Do not build this appl...

Page 3: ...OVEN 4 VALVE KNOB 3 COVEND 3 OVEN GASLINE 1 COVEN 7 OVEN VALVE 1 COVEN 9 RANGE VALVE 2 COVEND 1 REMOTE THERMOMETER 1 COVEN 22 REGULATOR 1 SPG25 17 MANIFOLD WASHER 1 SPG25 9 POT GRATE 1 COVEN 33 MANIFO...

Page 4: ...with dirt sand or baking soda 13 NEVER overfill the cooking pot with oil grease or water 14 When frying with oil or grease all food products MUST be completely thawed and towel dried to remove excess...

Page 5: ...y make a humming or whistling noise during operation This will not affect the safety or use of appliance Clean and inspect the optional bulk tank hose before each use of the appliance If there is evid...

Page 6: ...339 Cylinders Spheres and Tubes for the Transportation of Dangerous Goods The refillable propane cylinder used with this appliance must include a collar to protect the cylinder valve LP tank valve mus...

Page 7: ...OT lean over the Oven while lighting 1 Remove all appliances from the burner to create a free flow or air 2 Open lid Do not attempt to light the stove with the lid closed 3 Fully open LP bottle valve...

Page 8: ...cleaning and maintenance should only be done when the appliance is cool and with the fuel supply turned off at the LP cylinder DO NOT clean any part in a self cleaning oven The extreme heat will dama...

Page 9: ...e discarded without notice To obtain warranty services submit a warranty request at http www campchef com warranty information email warranty campchef com or call 1 800 650 2433 Our Product Specialist...

Page 10: ...10 www CampChef com 1 800 650 2433 Camp Chef is a registered trademark of Logan Outdoor Products 2018 3985 N 75 W Hyde Park UT 84318 USA Made in China 0118_COVEND_TRIBOOK...

Page 11: ...11 MODE D EMPLOI AVERTISSEMENTS MOD LES COVEND DELUXE FOUR D EXTERIEUR...

Page 12: ...sont pas obstru s ou que la circulation de l air n est pas restreinte par des objets ou d autres appareils plac s trop pr s des orifices Cet appareil n est pas destin tre encastr AVERTISSEMENT destin...

Page 13: ...FOUR 1 COVEN 7 ROBINET DU FOUR 1 COVEN 9 THERMOMETRE 1 COVEN 22 DETENDEUR 1 SPG25 17 RONDELLE DU MANIFOLD 1 SPG25 9 GRILLE PORTE PLATS 1 COVEN 33 MANIFOLD 1 COVEN 11 ALLUME GAZ DU R CHAUD 2 COVEN 14 B...

Page 14: ...ou que l huile commence fumer teindre le br leur SUR LE CHAMP 12 Si vous cuisinez l huile ou la graisse un extincteur doit tre port e de main En cas de feu d huile ou de graisse ne PAS essayer d teind...

Page 15: ...uteille et le d tendeur avec de l eau savonneuse Des bulles indiquent une fuite V rifier que le filetage du raccord n est pas fauss et que le raccord est serr V rifier une deuxi me fois la pr sence de...

Page 16: ...r tous les boutons de r glage en position OFF et fermer le robinet de la bouteille de GPL Tourner l crou de raccordement dans le sens contraire des aiguilles d une montre uniquement la main ne pas uti...

Page 17: ...notice Toujours maintenir les bouteilles de GPL d bout pendant l utilisation le transport et l entreposage qu il s agisse de nouvelles bouteilles ou de bouteilles chang es V rifier s il y a des fuite...

Page 18: ...montage de l adaptateur sous haute pression s assurer que la pression du gaz dans l adaptateur est limin e 2 Allumer le four et fermer le robinet d arriv e du gaz de la bouteille 3 Laisser la flamme s...

Page 19: ...et que l alimentation au gaz est coup e au niveau de la bouteille de GPL NE nettoyer AUCUNE pi ce dans un four autonettoyant La chaleur lev e ab mera les finitions Proc dure de nettoyage du br leur 1...

Page 20: ...e temp rature approximative de 100 C 10 C 212 F 20 F S il ne fonctionne pas correctement se procurer un thermom tre de rechange indiqu par le fabricant avant d utiliser l appareil Ne pas trop remplir...

Page 21: ...tion Camp Chef n est pas responsable des pertes ventuelles r sultant de la n gligence Par ailleurs cette garantie ne couvre pas les articles achet s aupr s d une tierce partie les concessionnaires non...

Page 22: ...22 www CampChef com 1 800 650 2433 Camp Chef is a registered trademark of Logan Outdoor Products 2018 3985 N 75 W Hyde Park UT 84318 USA Made in China 0118_COVEND_TRIBOOK...

Page 23: ...23 ADVERTENCIA E INSTRUCCIONES MODELO COVEND DELUXE HORNO AL AIRE LIBRE...

Page 24: ...alquier otro electrodom stico ADVERTENCIA Este producto contiene un componente qu mico que se conoce en el setado de California como c usante de c ncer ADVERTENCIA Tenga cuidado de las aberturas en el...

Page 25: ...ORNO 1 COVEN 4 V LVULA DE MANDO 3 COVEND 3 L NEA DE GAS HORNO 1 COVEN 7 V LVULA DE HORNO 1 COVEN 9 V LVULA DE ESTUFA 2 COVEND 1 TERM METRO 1 COVEN 22 REGULATOR 1 SPG25 17 MANIFOLD WASHER 1 SPG25 9 REJ...

Page 26: ...e el fuego con tierra arena bicarbonato de soda 13 NUNCA sobrellene la olla con aceite grasa o agua Siga las instrucciones en este manual para establecer los niveles apropiados de aceite grasa o agua...

Page 27: ...a El regulador puede hacer un ruido como un zumbido o silbido durante la operaci n Esto no afectar la seguridad o uso del aparato Limpie e inspeccione la manguera antes de cada uso del aparato Si hay...

Page 28: ...ula del cilindro La v lvula del tanque LP debe tener Salida tipo 1 compatible con el regulador o aparato V lvula de alivio de seguridad Dispositivo de Protecci n de Sobrellenado OPD listado por UL Est...

Page 29: ...completar la conexi n Aj stelo solo a mano no use herramientas NOTA Sino completa la conexi n desconecte el regulador y repita los pasos 5 y 6 Si todav a no puede completar la conexi n no use este reg...

Page 30: ...on una punta amarilla m nima Algunas puntas amarillas en las llamas son aceptables siempre y cuando no aparezcan dep sitos de carb n o de holl n Apagado de la cocinilla LP Gire todos los botones a la...

Page 31: ...ua Cuando fr a con aceite o grasa todos los productos alimenticios DEBEN completamente descongelarse o secarse con toalla para quitar el exceso de agua antes de sumergirlos en la freidora Aseg rese qu...

Page 32: ...eraciones hechas por alguien aparte de Camp Chef no est n cubiertas en esta Garant a El fabricante no estar obligado a responder por ninguna p rdida debido a operaci n negligente Adem s esta garant a...

Reviews: