3.
Once the azimuth base has been adjusted to its approximate location, lock the azimuth fixing pin by
rotating the pin clockwise until it appears to be aligned with its groove. At this point, you must adjust
the azimuth base until the fixing pin slips into its groove. There are notches within the device that enable
you to adjust the azimuth in 15° increments. You can then perform fine azimuth adjustment as described
below.
You will hear a click when the pin slips into the groove.
Summary of Contents for PTP 820E
Page 1: ......
Page 44: ...Page 44 of 110 1 Secure the cable to the gland using a tie wrap ...
Page 47: ...Page 47 of 110 8 Tighten the gland cap 9 Secure the cable to the gland with a tie wrap ...
Page 53: ...Page 53 of 110 4 Tighten the gland cap 5 Secure the cable to the gland using a tie wrap ...
Page 63: ...Page 63 of 110 Note For this type of installation a 2RU space is required ...
Page 71: ...Page 71 of 110 Figure 24 V 45 Polarization B on Top Figure 25 Vertical Polarization ...