4.
Place the mounting kit in front of the 4 anchor screws and tighten the 4 M8 screws, spring washers, and flat
washers to secure the mounting device to the wall.
Attaching the PTP 820E to the Installation and Alignment Device
1.
Connect the PTP 820E unit to the installation and alignment device, using the two M8 screws and washers
supplied with the installation and alignment kit. Attach the PTP 820E according to the desired polarization, as
shown in the figures below. Note that:
•
For vertical polarization, the upper screw must be approximately 2:00 to the right, the lower screw must
be approximately 8:00 to the left, and the RSL interface should be at approximately 9:00 to the left.
•
For horizontal polarization, the upper screw must be approximately 10:00 to the left, the lower screw
must be approximately 4:00 to the right, and the RSL interface should be at the bottom.
Figure 32: Horizontal Polarization – Radio and Installation and Alignment