Page 31 of 110
Pinout
Table 9: Outdoor Ethernet Cable Mechanical/Environmental Requirements
Jacket
UV resistant
Outer diameter
6-7.1 mm (in order to be compatible with the grounding clamp,
CAT5E_gnd_kit)
Operating and Storage
temperature range
-40°C - 85°C
Flammability rating
According to UL-1581 VW1, IEC 60332-1
RoHS
According to Directive/2002/95/EC
Outdoor DC Cable Specifications
Table 10: Outdoor DC Cable Electrical Requirements
Cable type
2 tinned copper wires
Wire gage
18 AWG (for
≤
150m (492ft) installations, optical connections)
14 AWG (for 150m ÷ 300m (492ft ÷ 984ft) installations, optical
connections)
Stranding
stranded
Voltage rating
600V
Spark test
4KV
Dielectric strength
2KV AC min