Table 11: Outdoor DC Cable Mechanical/Environmental Requirements
Jacket
UV resistant
Outer diameter
7-10 mm
Operating & Storage
temperature range
-40°C - 85°C
Flammability rating
According to UL-1581 VW1, IEC 60332-1
RoHS
According to Directive/2002/95/EC
Securing the Cables
All cables should be secured at every meter on-site using either a T-Rups kit or cable clamps. When using the T-
Rups kit, take special care to apply the proper amount of force in order to avoid damage to the cable. This is
especially important for optical (SFP) cables.
Special Instructions for use of Glands
Note
Each PTP 820E unit is supplied with two glands. If additional glands are required, they must be
ordered separately, in kits of five glands each.
Table 12: Glands Kit
Part number
Marketing Description
N000082L014A
PTP 820 Glands_x5_KIT
In addition, gland caps can be ordered to protect the cable and connector from damage when elevating the cable
and gland to the radio unit. See Step 5 in Section 3.8.1,
General Installation Procedure
. Gland caps are ordered
separately, in kits of 10 caps each.
Table 13: Gland Cap
Part number
Marketing Description
N800082L009A
PTP 820E Cable Protection Cap (Qty 10)
In order to remove the plastic plugs for the unit, you can use the flange of supplied glands to disconnect them as
shown in the figures below.
Summary of Contents for PTP 820E
Page 1: ......
Page 44: ...Page 44 of 110 1 Secure the cable to the gland using a tie wrap ...
Page 47: ...Page 47 of 110 8 Tighten the gland cap 9 Secure the cable to the gland with a tie wrap ...
Page 53: ...Page 53 of 110 4 Tighten the gland cap 5 Secure the cable to the gland using a tie wrap ...
Page 63: ...Page 63 of 110 Note For this type of installation a 2RU space is required ...
Page 71: ...Page 71 of 110 Figure 24 V 45 Polarization B on Top Figure 25 Vertical Polarization ...