EASY-DRIVER – User’s Manual
19
To make a secure and reliable connection a “Wire Ferrule Terminal” is strongly
suggested to use within the pilled wire as illustrated in
Figure 6
. Dimension of the
Ferrule have to be suitable for the wire cross section being used.
Figure 6
: Wire Ferrule Terminal
Tightening torque shall be between 1.2 to 2.4 Nm
2.6
Interlock connection
Each EASY-DRIVER power unit has one input interlock and one output status
signal that are directly available on the rear panel interlock connector. The interlock
connector is
Weidmuller
4-pin male connectors (Ordering Code 1599150000). The
mating connector that is provided with the EASY-DRIVER is the Weidmuller
1943580000.
The corresponding pin out is shown
Figure 7
:
Figure 7
: Interlock connector on the unit rear panel
The pin index is summarized in Table 3:
Pin Number
Description
1
Interlock (+)
2
Interlock return (-)
3
Status Relay Common
4
Status Relay Normally Open
Table 3:
Rear Interlock Connector pin out
1