Cleaning, maintenance and repairs
74
Translation of the Original Operating Manual
V-MIX Fix Plus
7.4
Oil change at the gear unit
Required gear oil for the gear unit:
SAE 80 W 85 (API GL5, VG 150).
An oil pump is needed to fill the gear unit.
Change the gear oil for the gear units Brevini ECS1512, Brevini EM1065 and Com-
er PGA1602:
for the first time after 100 operating hours,
every 1000 operating hours thereafter,
at least once per year (whichever interval comes first).
Change the gear oil for the reduction gearbox BvL 108960:
for the first time after 50 operating hours,
every 600 operating hours thereafter,
at least once per year (whichever interval comes first).
Dispose of the used oil as stipulated by law. If you experience problems with disposal,
contact your oil supplier!
If possible, the oil change should take place when the gear oil has warmed up to its operat-
ing temperature (30°C - 40°C). The gear oil flows best at operating temperature.
WARNING
If gear oil is spilled during an oil change, the resulting slip hazards can cause personal injury!
Clean up spilled oil immediately with a binding agent.