The following applies if a peening operation is to be monitored:
Only the peening displacement is monitored. The peening displacement starts when the lower
blocking force threshold is exceeded. The displacement value measured at this position is stored
(peening start position). The maximum peening displacement is determined like a slave pointer.
The relative peening displacement is calculated when the lower blocking force threshold is
exceeded. The peening displacement is monitored for two parameters.
Minimum peening displacement is the displacement that the peening operation must at least have
required. Maximum peening displacement is the displacement that must not be exceeded, since
otherwise manufacturing tolerances will not be observed.
Abbreviations:
WS = displacement start
TR = trigger
MS = measurement start
ME = measurement end
KSU = force threshold below
KSO = force threshold above
BS = block start
BE = block end
BSU = block threshold below
BSO = block threshold above
EE = end thread in
ESO = thread in threshold above
Key:
Region Thread in window Block window Gateway
Special case: Force monitoring only
If no displacement sensor is attached to ForceMaster 9110, none of the monitoring regions can be
used, since the ForceMaster 9110 cannot establish a relationship between force and
displacement.
There is only, therefore, a force threshold below (KSU) and a force threshold above (KSO).