33
of 95
D
evi
ce
co
nc
ep
t
3.13.2 List of possible commands
Command
Parameter
O1
Output 1
O2
Output 2
O3
Output 3
O4
Output 4
O5
Output 5
O6
Output 6
O7
Output 7
O8
Output 8
/O1
Reset output 1
/O2
Reset output 2
/O3
Reset output 3
/O4
Reset output 4
/O5
Reset output 5
/O6
Reset output 6
/O7
Reset output 7
/O8
Reset output 8
T1
Set timer 1 0.1 – 9.9 sec. (Input 1 = 0.1 sec)
T2
Set timer 2 0.1 – 9.9 sec.
/T1
Reset timer 1
/T2
Reset timer 2
JMP
Jump to target line
BE
Set beep
/BE
Reset beep
LO
Switch OK LED on
LN
Switch NOK LED on
/L
Switch LEDs off
CN+
NOK c1
CO+
OK c1
AE
Acknowledge error
3.14 "Cam" menu
This menu is only present on the ForceMaster 9110 with the step chain option.
The cams are an extension to the PLC. The PLC can query the electronic cams, and in that way
control automation procedures.
There is more information in Section 3.18, "Nockenschaltwerk".