Type 8756 BATCH
Setting and operation
32
Start the dosings:
Go to
Controller
>
Parameter
>
Start batch
Enter 1.
The product starts to dose. If the number of dosings to be performed in a row is higher than 1, then the
menu item
Dose counter
gives the number of performed dosings.
When the set number of dosings is completed, the value in the menu item
Start batch
changes to 0.
A second possibility is to start a dosing over the PDO, for example by a PLC.
8.2.4
Cyclic data (PDOs)
The product receives or transmits following cyclic data:
PDO number
Meaning
1
Start dosing
Tab. 19: Cyclic data received
PDO number
Meaning
1
Duration of the last dosing
Refer to
PDO1, Duration of the last dosing [
2
Dosing status
Refer to
Dosing information
Refer to
Dosed quantity during last dosing (in kg)
3
NAMUR status
Refer to
Error ID
Refer to
Fluid temperature (in K)
Tab. 20: Cyclic data transmitted
The transmission speed of the PDOs can be changed. Refer to
Transmission speeds of cyclic data [
8.2.4.1
PDO1, Duration of the last dosing
The value of PDO1 is the sum of the valve opening time and the product balancing time. The balancing time
is the time that is needed by the product to detect when the mass flow rate is equal to zero.
8.2.4.2
PDO2, Dosing status
Bit
Designation
Meaning
0
Init
The product is being initialized.
1
Ready
The product is ready to dose and is waiting for the command
to start a dose.