8.2
Dosing types
The product allows 2 types of dosing: quantity based dosing and timebased dosing. The settings for both
types of dosing are made either with the Bürkert Communicator software or with a PLC.
8.2.1
Quantity based dosing
Connect the product to the Bürkert Communicator software. Refer to
Connect the product to the Bürk-
In the Bürkert Communicator software, select the product.
The product status indicator flashes.
Go to
Controller
>
Parameter
Activate the dosing type:
Dose control mode
Choose
Quantity based dosing
.
Set the quantity to dose:
Setpoint dosing quantity
Enter the quantity to be dosed.
Set the number of dosings that are performed in a row when the dosing function is started:
Number of
doses
Enter the number of dosings.
If at least 2 dosings are performed in a row, then set the pause time between 2 dosings:
Time delay
between doses
Enter the pause time.
The quantity based dosing can be started. Refer to
8.2.2
Time based dosing
Connect the product to the Bürkert Communicator software. Refer to
Connect the product to the Bürk-
In the Bürkert Communicator software, select the product.
The product status indicator flashes.
Go to
Controller
>
Parameter
Activate the dosing type:
Dose control mode
Choose
Time based dosing
.
Set the time during which the on/off valve is open:
Setpoint activation time
Enter the dosing duration.
Set the number of dosings that are performed in a row when the dosing function is started:
Number of
doses
Enter the number of dosings.
If at least 2 dosings are performed in a row, then set the pause time between 2 dosings:
Time delay
between doses
Enter the pause time.
8.2.3
Start the dosings
Connect the product to the Bürkert Communicator software. Refer to
Connect the product to the Bürk-
In the Bürkert Communicator software, select the product.
The product status indicator flashes.