Set-up / Retrofit
19
Remove the spray air hose from the spray air adapter kit of the tank system.
6. Release the fastening screws (4 pieces) of the heat insulation with the Phillips screw-
driver. Remove the heat insulation consisting of 2 half-shells.
7. Release the electrical connections on the hose side as follows:
• 2 conductors at connection terminal for heater (brown, blue)
• 2 conductors at connection terminal for temperature sensor (2 x gray)
• 1 conductor at screwed connection of protective conductor (green/yellow)
8. Spray version only:
Release the union nut of the spray air hose.
9. Release the nut of the heatable hose with open-end wrench size 17.
Secure the connection to the heating cylinder with open-end wrench size 19.
10. Remove the hose from the heating cylinder. Keep on hand a rag or similar to be able
to wipe up discharged hot melt material right away before it can drip into the housing
of the manual application unit.
For spray version, remove the spray air hose together with the heatable hose.
Info
Assembling the heatable hose occurs in reverse order. Tighten the hose fitting only by
hand first. Permit the heatable hose and the manual application unit to heat up to approx.
100 °C before finally tightening the screws.
While tightening the hose fitting, make sure that the spray hose does not become twisted.
Refer to the circuit diagram in Chap. 2.2 when connecting the electrical lines.
When replacing the half shells, make sure that the flat portion of the arresting bars on the
inside of the half shell are seated properly on the corresponding counter pieces at the
heating cylinder.
Summary of Contents for HB 5010
Page 10: ...2...
Page 14: ...Special security advice 6...
Page 16: ...Technical data 8 Figure 2 1 2 Location of type plate on the inside of the unit...
Page 28: ...Operation 20...
Page 40: ...Operation 32...
Page 57: ...Repairs 49...
Page 60: ......
Page 62: ...Table of Contents 4 Table of contents...
Page 64: ...Specific security advice 6...
Page 68: ...Technical Data 10...
Page 76: ...Maintenance 18...
Page 80: ......
Page 82: ...4 Inhaltsverzeichnis...
Page 84: ...Specific safety instructions 6...
Page 90: ...Construction and function 12...
Page 92: ...Technical data 14...
Page 104: ...What happens if 26...
Page 107: ...Accessories 29...
Page 110: ...Ersatzteillisten...
Page 115: ...Spare parts list 3 1 HB 5010 Tank System basic unit Fig 1 1 Spare parts for basic unit Part 1...
Page 128: ...Spare parts list 16 2 3 Spare parts bead and spray 19 9 Fig 2 11 Grip casing both versions...
Page 129: ...Spare parts list 17 11 Fig 2 12 Heat insulation half shell both versions...
Page 130: ...18 Spare parts list 10 Fig 2 13 Trigger and mounting parts both versions...
Page 133: ...Table of contents 21...
Page 136: ...Table of Contents 2...
Page 138: ...4...