Installation / Initial operation
15
4
Installation / Initial operation
4.1
Set-up / Installation
820 mm
560 mm
Figure 4.1/1: Required space
After unpacking, place the system on a sturdy work surface that will securely bear the
weight of the system (38 kg). Lift the unit only by its frame.
Leave enough room at the sides (about 50 mm all round) to ensure unobstructed air circu-
lation.
Installation space of approx. 200 mm is required at the back to connect the hoses and to
set the pump pressure.
Set up the unit in such a way that it is protected from moisture, vibrations, and strong dust
accumulation. The permissible ambient temperature is 0…40 °C.
Figure 4.1/1
shows the required space.
4.1.1
Electrical connection
A protective conductor outlet with the following values is required for the electrical connec-
tion:
Voltage:
230 V AC
Frequency
50 Hz
Output:
2.9 kVA
Required fuse:
16 A
4.1.2
Mechanical connection (hoses)
Danger of burns!
When connecting the hoses, it is possible to receive burn injuries at the hose
connections.
Therefore, always wear heat protection gloves when doing this work.
Required tool
• 2 open-end wrenches size 19
To connect a hose, carry out the following work steps:
1. Shut down the tank system.
2. Connect the electrical hose connection with the corresponding connection of the tank
Summary of Contents for HB 5010
Page 10: ...2...
Page 14: ...Special security advice 6...
Page 16: ...Technical data 8 Figure 2 1 2 Location of type plate on the inside of the unit...
Page 28: ...Operation 20...
Page 40: ...Operation 32...
Page 57: ...Repairs 49...
Page 60: ......
Page 62: ...Table of Contents 4 Table of contents...
Page 64: ...Specific security advice 6...
Page 68: ...Technical Data 10...
Page 76: ...Maintenance 18...
Page 80: ......
Page 82: ...4 Inhaltsverzeichnis...
Page 84: ...Specific safety instructions 6...
Page 90: ...Construction and function 12...
Page 92: ...Technical data 14...
Page 104: ...What happens if 26...
Page 107: ...Accessories 29...
Page 110: ...Ersatzteillisten...
Page 115: ...Spare parts list 3 1 HB 5010 Tank System basic unit Fig 1 1 Spare parts for basic unit Part 1...
Page 128: ...Spare parts list 16 2 3 Spare parts bead and spray 19 9 Fig 2 11 Grip casing both versions...
Page 129: ...Spare parts list 17 11 Fig 2 12 Heat insulation half shell both versions...
Page 130: ...18 Spare parts list 10 Fig 2 13 Trigger and mounting parts both versions...
Page 133: ...Table of contents 21...
Page 136: ...Table of Contents 2...
Page 138: ...4...