What happens if…
43
9.2
Error messages in the display
Display
Cause
Remedy
Hose 1
Act=180
0
C Set=170
0
C
Overtemperature
Confirm with Enter
The temperature of the displayed
component (here: “Hose 1“) has
exceeded the permissible temper-
ature range in normal operation.
The message must be confirmed
with “Enter”
• Check whether the default
value for the target tempera-
ture during running operation
(„normal operation“) of the af-
fected component (see Chap.
6.3.2.3) was set to less than
the current actual temperature
minus the overtemperature
value (see Chap. 6.3.3.1,
“High”).
• Turn off the tank system and
allow it to cool down. If the
error occurs again after 30
minutes, notify Service.
Hose 1
Act=160
0
C Set=170
0
C
Undertemperature
Confirm with Enter
The temperature of the displayed
component (here: “Hose 1“) has
undercut the permissible tempera-
ture range in normal operation.
The message must be confirmed
with “Enter”
• Check whether the default val-
ue for the target temperature
during running operation („nor-
mal operation“) of the affected
component (see Chap. 6.3.2.3)
was set to greater than the
current actual temperature
plus the overtemperature value
(see Chap. 6.3.3.1, “Low”).
• Notify Service if this setting is
okay.
Hose 1
Act=185
0
C Set=170
0
C
Maximum temperature
Confirm with Enter
The temperature of the displayed
component (here: “Hose 1“)
has exceeded the permissible
maximum temperature in normal
operation. The message must be
confirmed with Enter
• Check whether the default
value for the target tempera-
ture during running operation
(„normal operation“) of the af-
fected component (see Chap.
6.3.2.3) was set to less than
the current actual temperature
minus the maximum tempera-
ture value (see Chap. 6.3.3.1,
“Max”).
• Turn off the tank system and
allow it to cool down. If the
error occurs again after 30
minutes, notify Service.
Tank
Short circuit
Confirm with Enter
The temperature sensor of the
affected component is defective.
The message must be confirmed
with “Enter”
The heater of the component is
turned off.
• Notify Service.
Hose1
missing
Confirm with Enter
• The affected component (here:
“Hose 1”) has not been con-
nected (electrically).
or
• The temperature sensor of the
component is defective.
• Establish the electrical connec-
tion of the component.
• Notify Service.
Display
Error Time/Date
Confirm with Enter
The control unit has “lost” the cur-
rent date.
• Set the correct date and time.
• If the error occurs again:
Replace the back-up battery of
the control unit (see chap. 8.3).
Summary of Contents for HB 5010
Page 10: ...2...
Page 14: ...Special security advice 6...
Page 16: ...Technical data 8 Figure 2 1 2 Location of type plate on the inside of the unit...
Page 28: ...Operation 20...
Page 40: ...Operation 32...
Page 57: ...Repairs 49...
Page 60: ......
Page 62: ...Table of Contents 4 Table of contents...
Page 64: ...Specific security advice 6...
Page 68: ...Technical Data 10...
Page 76: ...Maintenance 18...
Page 80: ......
Page 82: ...4 Inhaltsverzeichnis...
Page 84: ...Specific safety instructions 6...
Page 90: ...Construction and function 12...
Page 92: ...Technical data 14...
Page 104: ...What happens if 26...
Page 107: ...Accessories 29...
Page 110: ...Ersatzteillisten...
Page 115: ...Spare parts list 3 1 HB 5010 Tank System basic unit Fig 1 1 Spare parts for basic unit Part 1...
Page 128: ...Spare parts list 16 2 3 Spare parts bead and spray 19 9 Fig 2 11 Grip casing both versions...
Page 129: ...Spare parts list 17 11 Fig 2 12 Heat insulation half shell both versions...
Page 130: ...18 Spare parts list 10 Fig 2 13 Trigger and mounting parts both versions...
Page 133: ...Table of contents 21...
Page 136: ...Table of Contents 2...
Page 138: ...4...