3.4 - Probe cleaning system (option)
40
TCT-2301 Installation instructions
M2007/3en
©BTG 2004
3.4.3
Installing the PCD-1000 probe cleaning
device
This section describes how to install the probe cleaning device
PCD-1000/A that is delivered with a TCT-2301 probe. (Option)
!
Make sure the pipe is empty and pressureless before starting the
installation
1. Loosen the screws (3) that holds the protective sleeve (4) fixed.
2. Loosen the nuts (2).
3. Turn the probe, by turning the protective sleeve, until the measuring
gap is at a 45° angle to the pulp flow. The slot (3) on the protective
sleeve is aligned with the measuring gap. Use the angle scale on the
rear cylinder flanged end for assistance.
4. Tighten the screws (3) to fasten the protective sleeve (4) and to fix
the angle of the probe.
5. Loosen the screws (1).
6. Turn the flushing valve (6) so that the inlet faces the measuring gap
of the probe. The air cylinder shall at this stage have its quadratic ex-
ternal cross section turned the same way as the flanged ends of the
ball valve.
7. Tighten the screws (1) and nuts (2).
8. Remove the flanged weld-in stud from the cleaning device and weld
the flanged weld-in stud to the pipe, according to section 3.2.4.
9. Remount the PCD-1000 to the flanged weld-in stud.
4
3
5
2
1
6
Fig 31 Mounting the weld in
stud