Connection terminals
The screw terminals for the alarm inputs are suitable for use with a standard 3mm blade
terminal screwdriver.
Power connections
Power to the unit is via two screw terminals at the centre, with positive to the right,
nearest Pin 5.
The supply voltage range is 9V to 30V. We’ve designed the unit to be connected to
the auxiliary power output on an associated alarm panel, or separate powered
enclosure. For use with intruder alarm panels, the power supply must meet the
requirements of EN 50131-6.
Make sure the power source is sufficient to power all devices connected (see power
requirements in the specification section for more information). The account at the Alarm
Receiving Centre (ARC) should be put ‘on test’ before powering up, as the unit will send
signals following initialisation
Alarm inputs
The unit has eight alarm inputs, presented on screw terminals along the bottom of the
unit. These are labelled as Pin 1-4 and 5-8.
By default, the eight alarm inputs need a positive condition to be presented to send an
alarm. (Default = Positive applied). This can be changed using the Pin Learn button or
through the configuration menu. See later section on Configuration for details.
Input (Pin)
Use
1
2
Hold up alarm
3
Intruder alarm
4
Open / Close (Set / Unset) (FUNC output can be set up as RPS in conjunction with Pin 4)
5 – 6
General alarm
7
Confirmed alarm
8
General alarm
Figure 3 – Alarm input allocations. Functions must be agreed with your ARC.