What happens when pins are configured and wired in this way
When pins are configured and wired in this way, the dual resistor EOL mode is able to
detect four states:
• Alarm event
• Restore
• Wire cut
• Wire shorted
The OLED display will indicate the
wire cut condition for any of Pins
1-8 that are presently in the wire cut
state.
Above, example Cut on Pin 6.
Above, example Short on Pin 8.
The OLED display will indicate the
wire short condition for any of Pins
1-8 that are presently in the wire cut
state.
Alarms GPI Cut
6
Alarms GPI Short
8
Panel Upload Download and Enhanced format signalling (SIA/CID)
You can have remote access to the alarm panel using the BT Redcare UDL facility.
Additional panel set-up information is also available for enhanced format signalling.
Contact your BT Redcare representative for further details.
Dial Capture
The Dial Capture pins present a ‘phone line’ to the panel’s on-board digital
communicator. Connect the alarm panel’s digital communicator line connections to
the terminals marked DIAL CAP on the unit. The terminals are not polarity-conscious.
Configure the alarm panel digital communicator to Dial 29 and use the last four digits
of the TAID as the account number.
The dial capture board will auto-detect the panel protocol, as events are sent from the
alarm panel – SIA, CID or FF.
Please check current panel compatibility listing.
You can easily spot any issues and put them right, by connecting a test phone or listening
device to the dial capture inputs. The Dial Capture pins with a test phone connected and
line seized (as if making a phone call) will give a continuous tone like a dialling tone. They
will display a voltage of 45V.
Serial panel connections
Select the required panel in the Serial Panel Type menu option via the buttons, app
or web portal.
Please contact your BT Redcare representative for the latest information on panel
compatibility for Upload, Download and Enhanced format signalling via serial
connections.
Then wire in the panel using the GND, TX/B and RX/A terminals.
57