Commissioning
B 3
ekrPro Com
60
web guide controller
EDV No.:
MD.191.01.05/1.6.x Chapter:
B 3
with analog sensors
Date:
23.11.2007
Page:
63/73
B 3.7.5.9.3
Truth table
Default values for digital input allocation: Dig. InTable 1
Terminal
Line
Significance
85
84
83
82
81
80
79
78 77 76 75
74
1 set
Auto
(automatic mode)
X X X X X X X X X
1
0
0
2 set
MAN
(manual mode)
X X X X X X X X X
0
0
1
3 set
SC
(servo center position)
X X X X X X X X X
0
1
0
4 opmode
clear
(defined zero state operating mode)
X X X X X X X X X
0
0
0
5 set
Edge1
(edge 1)
X X X X X X
0
0
1
X X X
6 set
Edge2
(edge 2)
X X X X X X
0
1
0
X X X
7 set
Center1&2
(center 1/2)
X X X X X X
0
1
1
X X X
8 set
Edge3
(edge 3)
X X X X X X
1
0
0
X X X
9
set Edge3 Inv. (inverse edge 3)
X X X X X X
1
0
1
X X X
10 guid.mode
clear
(defined zero state guiding mode)
X X X X X X
0
0
0
X X X
11 Motor
stop
X X X
0
0
0
X X X X X X
12 Motor
stop
X X X
0
0
1
X X X X X X
13 FVG
stop
X X X
0
0
0
X X X X X X
14 FVG
stop
X X X
0
0
1
X X X X X X
15 Motor
left
X X X
0
1
0
X X X X X X
16 FVG
left
X X X
0
1
1
X X X X X X
17 Motor
right
X X
X
1
0
0
X X X X X X
18 FVG
right
X X
X
1
0
1
X X X X X X
19 Motor
stop
X X
X
1
1
0
X X X X X X
20 FVG
stop
X X
X
1
1
1
X X X X X X
21
Set Lim.Sw. 1
(stop switch 1)
X
1
0
X
X
X X X X X X X
22
Reset Lim.Sw. 1
(reset stop switch 1)
X
0
0
X X X X X X X X X
23
Reset Lim.Sw. 1
(reset stop switch 1)
X
1
1
X X X X X X X X X
24
Set Lim.Sw. 2
(stop switch 2)
X
0
1
X X X X X X X X X