Commissioning
B 3
ekrPro Com
60
web guide controller
EDV No.:
MD.191.01.05/1.6.x Chapter:
B 3
with analog sensors
Date:
23.11.2007
Page:
40/73
Once the selection has been made, specific settings must be carried
out for the
FVG eco
,
FVG 1MK Op.
and
FVG 2MK Op.
modes.
B 3.7.5.5.2 FVG eco
The
FVG eco
mode allows the sensors/FVG slides belonging to the
FVG connected to be moved using the controller arrow keys. It
effectively represents manual operation of the FVG.
For this reason, automatic edge search functions and web width
adjustment are inactive in this mode.
The specific settings are analogue to those in the
Internal FVG
. The
procedure is described under point 3.7.5.5.3.
B 3.7.5.5.3 Internal FVG
The
Int. FVG
submenu is used when the
FVG 1MK Op.
mode has
been selected (normally when using a FVG 1K or FVG 1MK).
Homing Direction –
Retraction direction and limit switch assignment
The sensor’s retraction direction and the assignment of the limit
switches are set up in the next steps.
1. Mark
Int. FVG
in the
FVG
selection window and then confirm
by pressing ENTER. Select
Homing Dir.
from the sub-
directory and then press ENTER to open the inputting menu.
2. Press the
F1
key to check the selected retraction direction.
By pressing the
F1
key, the FVG slide must move outwards
(into the homing position).
After the homing position is reached, the limit switch with the
outer
label must be activated ( ).
Exit the window without making any changes if the homing
direction and limit switch assignment are correct.
If the FVG slide moves inwards when the
F1
key is pressed,
then the checkbox
Homing dir. inv
. should be activated.
If the limit switch with label
inner
is activated in the homing
position, then the checkbox
Ref. switch inv.
should be
activated.
Note:
If the limit switch is activated but no checkbox
(
outer
or
inner
) is activated, then the limit switch
requires
testing.
3. Press
the
ESC
button to exit the inputting menu after you
have entered the setting.
123
456
789
0
Change User
Material Setup
Sel. Std. System
opt. Logic
General Setup
Actuator
Sensors/EFE
Control Loop
FVG
Connected
Retract Mode
Err. Behaviour
Homing Dir.