Commissioning
B 3
ekrPro Com
60
web guide controller
EDV No.:
MD.191.01.05/1.6.x Chapter:
B 3
with analog sensors
Date:
23.11.2007
Page:
16/73
- Range – Traversing range limits
• at the first setting after switching on:
min =
0.0
max = 5000.0
- Feed – Feed for stepping motor / gearing combination
This setting is treated as the feed per motor revolution for the
stepping motor / gearing combination.
The respective value is automatically entered when the FVG type
is selected:
for FVG 1MK60 = 20088
for FVG 1MK75 = 61666.
The manufacturer has entered this default setting and you are
only permitted to modify it (if necessary) after having obtained the
manufacturer’s agreement.
The relevant procedure then has to be agreed.
All warranty claims will be invalidated in any other case.
3. Selection
IR2005:EMS17:2MK60
or
IR2005 EMS17:2MK75
resp
.
US2007:EMS17:2MK60
or
US2007:EMS17:2MK75
If one of these configurations is selected, the "
FVG 2MK Op.“
sensor positioning device connection is selected and entered.
The following settings-dependent parameters are selected and
entered for the FVG 1 (Slide 1)and the FVG 2 (Slide 2):
Slide 1
- Homing Direction – retraction direction and limit switch
assignment
• at the first setting after switching on:
not
reversed
- Offset - positional offset to FVG position
• at the first setting after switching on:
Offset = 2000
Inverted = no
- Range – Traversing range limits
• at the first setting after switching on:
min = 0.0
max = 5000.0
- Feed – Feed for stepping motor / gearing combination
This setting is treated as the feed per motor revolution for the
stepping motor / gearing combination.
The respective value is automatically entered when the FVG type
is selected:
for FVG 2MK60 = 20088
for FVG 2MK75 = 61666.
The manufacturer has entered this default setting and you are
only permitted to modify it (if necessary) after having obtained the
manufacturer’s agreement.
The relevant procedure then has to be agreed.
All warranty claims will be invalidated in any other case.