B 3.7.5.9.4 Outputs –
Digital outputs
This sub-menu allows various messages to be assigned to the
digital outputs of the control unit (terminal 64 – 67).
The meaning of the individual messages can be taken from the table
on the following page.
1. Select
Dig. IO Config.
in General Setup and then select the
Outputs” sub-directory afterwards.
Confirm the respective selection by pressing ENTER.
2. The digital outputs setting window opens.
3. Select the option list for the desired terminal (64 – 67) using
the horizontal arrow keys and press ENTER.
4. In the opened option list mark the message that is to be
allocated to the selected terminal and press ENTER.
5. Set interface conditions for the signal via the checkbox
Low act.
.
Signal = high active
Î
deactivate checkbox
Signal = low-active
Î
activate checkbox
By pressing
F4
(
def.
) the allocated messages and interface
conditions are reset for all terminals (64 – 67) to the factory
settings.
6. Press the "
ESC
" button to exit the window after allocating the
messages.
def.
Dig. Outp. Cond. Low act.
64 s
65 W. warn nor err. min.
66 W. warn nor err. max.
67 Hyd. Lock
no Error