Commissioning
B 3
ekrPro Com
60
web guide controller
EDV No.:
MD.191.01.05/1.6.x Chapter:
B 3
with analog sensors
Date:
23.11.2007
Page:
48/73
• Lvl. Outer:
The approach of the sensor towards the
material web generally occurs from the outside.
The FVG operating mode can be carried out in the
MAN
mode, in the
Automatic
mode as well as the
SC
mode.
However, the change will only become effective in the
controller after the operating mode has been changed again.
If, for example, you want to change over and you are in
Automatic
mode then you must change over to
MAN
mode
and then back to
Automatic
mode again. Only then will the
change become effective.
4. Press the
ESC
button to exit the window.
B 3.7.5.5.8 - Repositioning – repositioning of the material
after certain events
The current position of the material web is saved once an event
takes place (e.g. web tear). Once the event has been rectified, the
material is repositioned to this position. This functionality is only
effective once pre-positioning has been activated.
1. Select
“
Repositioning
“ from the sub-menu and then press
ENTER.
2. Activate the required behaviour in the settings menu.
The web/sensor position is saved after a web tear has
occurred.
The web/sensor position is saved at the time of switching
over from
Automatic
operating mode to
Manual
or
SC
operating mode.
3. Press
the
ESC
button to exit the inputting menu after you
have made the selection.
25% covering
Start of sensor tracking
75% covering
Start of sensor tracking
50% covering
End position