Commissioning
B 3
ekrPro Com
60
web guide controller
EDV No.:
MD.191.01.05/1.6.x Chapter:
B 3
with analog sensors
Date:
23.11.2007
Page:
43/73
B 3.7.5.5.4 FVG Pro
The
FVG Pro
submenu is used when the
FVG 2MK Op.
mode has
been selected (usually when using an FVG 2MK). In this case, each
FVG needs to be adjusted separately. The terms used here
FVG 1
(Slide 1) and
FVG 2
(Slide 2) relate to the arrangements in
accordance with Point A 1.4.5.
The safety features are identical for both FVGs. The procedure for
FVG 1
(Slide 1) is used as the example here:
Homing Direction –
Retraction direction and limit switch assignment
The retraction direction of the sensors and the assignment of the
limit switches are set up in the next steps.
1. Mark
FVG Pro
in the FVG selection window and then
confirm by pressing ENTER. Select
Slide 1
and confirm by
pressing ENTER.
2. Select
Homing Dir.
from the sub-directory and then press
ENTER to open the inputting menu.
3. Press
the
F1
key to check the selected retraction direction.
By pressing the
F1
key, the FVG slide must move outwards
(into the homing position).
After the homing position is reached, the limit switch with the
outer
label must be activated ( ).
Exit the window without making any changes if homing
direction and limit switch assignment are correct.
If the FVG slide moves inwards when the
F1
key is pressed,
then the checkbox
Homing dir. inv.
should be activated.
If the limit switch with label
inner
is activated in the homing
position, then the checkbox
Ref. switch inv.
should be
activated.
Note: If the limit switch is activated but no checkbox
(
outer
or
inne
r) is activated, then the limit switch
requires
testing.
4. Press
the
ESC
button to exit the inputting menu after you
have entered the setting.