Controls
C 1
ekrPro Com
60
web guide controller
EDV-No.:
MD.191.00.05/1.6.x Chapter: C
1
with analog sensors
Date:
23.11.2007
Page:
6/6
Editing box
The arrow keys can also be used to enter a value in the editing box
in addition to using the F-keys.
Use the horizontal arrow keys
to position the cursor on
the number to be modified.
Now use the vertical arrow keys
to increase or decrease
the number.
Press ENTER to import the entered value.
Press the ESC button to cancel the value if you do not want to
save it.
Entering negative numbers
Use the horizontal arrow keys
to mark the initial
position for the setting.
Now use the vertical arrow keys
so that the minus
sign is entered or removed.
After this, enter the digit sequence as described above.
C 1.2.3 Buttons
Button control elements are present in certain dialog windows
If a button is marked and the ENTER button is pressed afterwards,
an action will be executed (e.g. traversing the actuator).
The button will be displayed as being pressed down and the action
will continue to be executed all the time that the ENTER button is
kept pressed down.
78.5
0
123
456
789
0
Width Measure Offset
current width:
enter ref.width
mm
Opened
editing box
Selected
digit
=
Select a sensor type
sensor1
dark
bright
-2048 abs. 1775
2047
auto
dark
bri.
<<<
IR 2005
Inv.
7%