GS-X Pinsetter w/Advanced (CE) Guarding Operation Manual
55
PROBLEM
CAUSE
CORRECTIVE ACTION
5.
Pinsetter cycles continuously.
1.
2.
"SET" switch on mechanic's rear
control box stuck or faulty.
Bowler's reset button stuck or cable
is shorted.
1.
2.
Replace or repair as needed.
Check reset button, check cable,
repair or replace.
6a.
No pinsetter motor will operate.
1.
2.
3.
Safety switches TS1 or TS2
actuated.
Manager's remote control unit not
turned on. (Stand Alone pinsetters
only)
Faulty Nexgen H.V. PCB
1.
2.
3.
Determine cause of trouble,
repair, and restart machine.
Turn on switch.
Relplace Nexgen H.V. PCB.
6b.
Individual motor does not operate.
1.
2.
3.
4.
Main house breaker box or faulty
power supply connections.
Faulty cables.
Damaged motor.
All above checked faulty Nexgen
CPU or H.V. PCB.
1.
2.
3.
4.
Check breaker box and tighten
power connections.
Check for shorted or loose pins,
continuity, faulty connectors.
Repair or replace.
Replace motor.
Power down and exchange faulty
box.
7.
Pinsetter fails to sweep.
1.
2.
3.
4.
Pin under or on top of sweep.
Faulty switch G, OOR or SM.
Sweep wagon guide rollers not
adjusted properly.
Broken or worn sweep drive belt.
1.
2.
3.
4.
Remove pin.
Adjust or replace switch.
Adjust guide rollers.
Replace belt.