GS-X Pinsetter w/Advanced (CE) Guarding Operation Manual
17
Pinsetter
Power-up Procedure - Safety Controller
1. Verify that the photo sensors are aligned with no obstructions, the masking unit and ball
return door interlocks switches are closed and the emergency stop switch on the safety
controller in not activated (Twist the E-stop button to deactivate). Turn main power switch to
the “On”
position.
- The safety controller will start an initial power up diagnostics to verify conditions.
- The green “Restart Photosensor” LED will illuminate.
2. Press the photosensor restart button to activate the photosensor located on the masking unit.
- The green LED will go off and the yellow “Ready for Restart” LED will illuminate.
3. Press the blue “Restart” button located on the GS-X Safety Controller box to activate the
interlock switches.
- The yellow LED will go off and the red “Power On” LED will illuminate.
- Power will be supplied to the GS-X Nexgen.
VERIFY ALL INTERLOCKS
AND SENSORS ARE IN
THEIR PROPER POSITION
TURN THE MAIN POWER
SWITCH “ON”
(GREEN LED “ON”)
PRESS “PHOTO SENSOR
RESTART” BUTTON
(YELLOW LED “ON”)
PRESS “RESTART” BUTTON
ON CONTROLLER
(RED LED “ON”)
REMOVE THE SOURCE
OF THE SENSOR
OBSTRUCTION
PRESS “PHOTO SENSOR
RESTART” BUTTON
(YELLOW LED “ON”)
PRESS “RESTART” BUTTON
ON CONTROLLER
(RED LED “ON”)
VERIFY ALL INTERLOCKS
ARE IN THEIR PROPER POSITION
(YELLOW LED “ON”)
PRESS “RESTART” BUTTON
ON CONTROLLER
(RED LED “ON”)
Pinsetter Restart Procedure - Safety Controller
The photo sensor has been obstructed (Green, “Restart Photosensor” LED, “ON”)
1. Remove obstruction from photo sensors.
2. Press the photosensor restart button to re-activate the photo sensors.
3. Press the blue “Restart” button located on the GS-X Safety Controller box.
REMOVE THE SOURCE
OF THE SENSOR
OBSTRUCTION
PRESS “PHOTO SENSOR
RESTART” BUTTON
(YELLOW LED “ON”)
PRESS “RESTART” BUTTON
ON CONTROLLER
(RED LED “ON”)
The Ball Return Interlock or Masking Unit Interlock is triggered.
1. Return the masking unit and/or the ball return access door to the “closed” position.
2. Press the blue “Restart” button located on the GS-X Safety Controller box to re-activate the
interlock switches.
VERIFY ALL INTERLOCKS
ARE IN THEIR PROPER POSITION
(YELLOW LED “ON”)
PRESS “RESTART” BUTTON
ON CONTROLLER
(RED LED “ON”)