GS-X Pinsetter w/Advanced (CE) Guarding Operation Manual
45
Machine Cycle Diagnostics
1. To enter into this mode, the following conditions are necessary.
a. The pinsetter cannot be in an error condition.
b. The stop/run switch for the pinsetter is being tested must be switched to the “stop”
position.
c. All other interlock switches or other stop/run switches must be on.
2. To activate cycle diagnostics, press the [Mode] key on the control panel until the mode “Diag”
appears on the display.
3. Turn the stop/run switch for the pinsetter is being tested to the “run” position.
4. If a pinsetter stops during diagnostics and the status light is flashing, check the error code
displayed on the mechanic’s remote display. Refer to
Table 1.
NOTE:
In order to see error codes 50-59 (Detect 1 - Detect 9, Detect 10) in Machine
Diagnostics, the Enable 50 ERR must be set to Y.
Tables 1
and
2
list possible error codes and describe the most likely cause for the error. The displayed
code may not pinpoint the problem in all cases. For further explanation of the codes, refer to the
“
Troubleshooting”
section of this manual.