![Brother DCP 8060 Servise Manual Download Page 487](http://html.mh-extra.com/html/brother/dcp-8060/dcp-8060_servise-manual_53143487.webp)
Scanner Error Code
Define name
Error Code
Contents
SCDIAG_OK
0
The processing is completed or confirmation is successful.
SCDIAG_FAIL
1
The system stopped processing due to errors which don't fall into ones above, such as the lack of memory.
SCDIAG_NOT_INITIALIZE
2
The system tried to run functions without the initialization processing.
SCDIAG_NOT_SUPPORT
3
This Scanner driver type doesn't support the function which is tried to run, This confirmation of the function is not necessary.
SCDIAG_NOT_INSTALL
4
The specified device is not installed.
SCDIAG_NOT_CONNECTED
5
The specified device is not connected. (only USB connection)
SCDIAG_NOT_FOUND_DEVICE
6
The specified device is not found, No device may be connected or may fail to install.
SCDIAG_NOT_FOUND_TWDS
10
The specified TWAIN Data Source is not found, No device may be connected or may fail to install.
SCDIAG_NOT_SELECT_TWDS
11
The TWAIN Data Source Manager fails to recognize the default TWAIN Data Source.
SCDIAG_TWAIN_SYSTEM_ERROR
12
The TWAIN Data Source Manager to use the TWAIN protocol is not available.
The TWAIN Data Source Manager may not exist.
SCDIAG_STIDEVICE_CREATE_FAIL
20
The system failed to create the STI device.
The STI/WIA service or the minidriver may have problems.
SCDIAG_STI_SYSTEM_ERROR
21
The STI Interface (IStillImage) is not available.
The STI service may not start or the operation system may have problems.
SCDIAG_WIADEVICE_CREATE_FAIL
30
The system failed to create the WIA device.
The WIA service or the minidriver may have problems.
SCDIAG_WIA_SYSTEM_ERROR
31
The WIA Service (IWiaDevMgr Interface and so on) is not available.
The WIA service may not start or the operation system may have problems.
SCDIAG_OPEN_ERROR
40
The system failed to open the scanner device.
The attempt may be rejected because the object device is running or so.
SCDIAG_WRITE_ERROR
41
The system failed to send the scanner command.
SCDIAG_READ_ERROR
42
The system failed to read the data from the device.
SCDIAG_TIMEOUT
43
The system failed to receive the response after the request has timed out.
SCDIAG_NO_RSM
44
The system failed to recognize the Resource Manager and failed to restart.
The Resource Manager may not be installed or running incorrectly.
Scanner Error Code
Confidential
Summary of Contents for DCP 8060
Page 19: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Page 28: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Page 65: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Page 92: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Page 95: ...Confidential 4 2 Cover page sample End page sample ...
Page 96: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 246: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 292: ...Confidential CHAPTER 7 CLEANING ...
Page 294: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Page 302: ...8 7 Confidential For white and black scanning a b c d e f g h i j ...
Page 314: ...8 19 Confidential Cover page sample End page sample Fig 8 10 ...
Page 323: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Page 458: ...B Power Supply PCB 100V Confidential ...
Page 459: ...B Power Supply PCB 200V Confidential ...