5-95
5.1.72 T1 Solenoid ASSY
(1) Remove the bind B M3x10 Taptite screw.
(2) Remove the T1 solenoid ASSY and the Solenoid release spring.
Fig. 5-138
5.1.73 Toner Sensor PCB
(1) Remove the Toner sensor PCB unit ASSY from the Frame L.
Fig. 5-139
(2) Remove the PT sensor holder from the Toner sensor PCB ASSY AL.
Fig. 5-140
Taptite, bind B M3x10
Solenoid release spring
T1 solenoid ASSY
Frame L
T1 solenoid lever
Frame L
Hooks
Toner sensor PCB unit ASSY
PT sensor holder
Toner sensor PCB ASSY AL
Hooks