App.
4-5
Confidential
WSW03
(PABX* mode setting)
Selector
No.
Function
Setting and Specifications
1
CNG detection when sharing a
modular wall socket with a
telephone
0: A
1: B
2
|
4
Detection time length of
PABX* dial tone, required
for starting dialing
(Not used.)
No. 2 3 4
0 0 0 : 50 ms
0 0 1 : 210 ms
0 1 0 : 500 ms
0 1 1 : 800 ms
1 0 0 : 900 ms
1 0 1 : 1.5 sec.
1 1 0 : 2.0 sec.
1 1 1 : 2.5 sec.
5
CNG detection when sharing
a modular wall socket with a
telephone
0: A
1: B
6
7
Dial tone detection in
PABX* (Not used.)
No. 6 7
0 0 : No detection (3.5 sec. WAIT)
0 1 : No detection (5 sec. WAIT)
1 0 : No detection (7 sec. WAIT)
1 1 : Detection (Frequency only)
8 Not
used.
* PABX: Private automatic branch exchange
NOTE:
Selectors 2 through 4, 6 and 7 are not applicable where no PABX is installed.
- Selectors 1 and 5: CNG detection when sharing a modular wall socket with a telephone
These selectors determine whether or not the machine detects a CNG signal when a line is
connected to a telephone sharing a modular wall socket with the machine. Upon detection of CNG
signals by the number of cycles specified by these selectors, the machine interprets CNG as an
effective signal and then starts FAX reception.
Selector
No. 1 No. 5
Cycle
0 (A) 0 (A)
0 (A) 1 (B)
1 (B) 0 (A)
1 (B) 1 (B)
0.5 cycle
1.0 cycle
1.5 cycles
2.0 cycles
- Selectors 2 through 4: Detection time length of PABX dial tone, required for starting dialing
(Not used.)
Upon detection of the PABX dial tone for the time length set by these selectors, the machine starts
dialing.
These selectors are effective only when both selectors 6 and 7 are set to "1" (Detection).
Summary of Contents for DCP 8060
Page 19: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Page 28: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Page 65: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Page 92: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Page 95: ...Confidential 4 2 Cover page sample End page sample ...
Page 96: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 246: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 292: ...Confidential CHAPTER 7 CLEANING ...
Page 294: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Page 302: ...8 7 Confidential For white and black scanning a b c d e f g h i j ...
Page 314: ...8 19 Confidential Cover page sample End page sample Fig 8 10 ...
Page 323: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Page 458: ...B Power Supply PCB 100V Confidential ...
Page 459: ...B Power Supply PCB 200V Confidential ...
Page 495: ...January 06 SM FAX049 8C5B03 9 Printed in Japan ...