App.
4-34
Confidential
WSW30
(Function setting 8)
Selector
No.
Function
Setting and Specifications
1
|
3
Dial tone/busy tone detection
level during recording of ICM
(Not used.)
No. 1 2 3
0
0
0
:
-38.0
dBm
(A)
0
0
1
:
-39.5
dBm
(B)
0
1
0
:
-41.0
dBm
(C)
0
1
1
:
-42.5
dBm
(D)
1
0
0
:
-44.0
dBm
(E)
1
0
1
:
-45.5
dBm
(F)
1
1
0
:
-47.0
dBm
(G)
1
1
1
:
-48.5
dBm
(H)
4
Duty cycle control of pulsed
current for the heat-fuser unit
0: OFF
1: ON
5
"CLEAN DRUM" display
0: Yes
1: No
6
7
Not used.
0: Normal
1: Dark
8
Text mode copy density
adjustment
0: Normal
1: Dark
NOTE:
Selectors 1 through 3 are applicable to models equipped with internal TADs.
NOTE:
Selectors 4 is applicable to the European version only.
- Selectors 1 through 3: Dial tone/busy tone detection level during recording of ICM (Not used.)
If the machine (called station) detects dial tone (400 Hz continuously) or busy tone (400 Hz
intermittently) exceeding the detection level specified by these selectors for the period specified by
selectors 1 through 4 on WSW35, then it interprets the calling station as being disconnected. The
machine stops TAD recording and disconnects the line.
- Selectors 4: Duty cycle control of pulsed current for the heat-fuser unit
Setting this selector to "1" activates the duty cycle control that suppresses the rush current.
The duty cycle is 10ms ON and 20ms OFF.
However, the duty cycle control may emit switching noise to the AC line. Depending upon the
codes and regulations in the country, this selector should be set to "0".
Summary of Contents for DCP 8060
Page 19: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Page 28: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Page 65: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Page 92: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Page 95: ...Confidential 4 2 Cover page sample End page sample ...
Page 96: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 246: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 292: ...Confidential CHAPTER 7 CLEANING ...
Page 294: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Page 302: ...8 7 Confidential For white and black scanning a b c d e f g h i j ...
Page 314: ...8 19 Confidential Cover page sample End page sample Fig 8 10 ...
Page 323: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Page 458: ...B Power Supply PCB 100V Confidential ...
Page 459: ...B Power Supply PCB 200V Confidential ...
Page 495: ...January 06 SM FAX049 8C5B03 9 Printed in Japan ...