![Brother DCP 8060 Servise Manual Download Page 165](http://html.mh-extra.com/html/brother/dcp-8060/dcp-8060_servise-manual_53143165.webp)
Confidential
5-64
5.1.47 Scanner Unit ASSY
(1) Disconnect the connector of the Scanner motor harness from the Driver PCB.
(2) Disconnect the connector of the Photo interrupter and FFC cable from the Main PCB.
Fig. 5-80
(3) Remove the two cup B M4x20 Taptite screws. Lift up the rear of the Scanner unit FLFB
slightly and remove the Scanner unit FLFB.
Fig. 5-81
Taptite, cup B M4x20
Taptite, cup B M4x20
Driver PCB
Scanner motor harness
FFC cable
Photo interrupter
Main PCB
Scanner unit FLFB
Hook
Hook
Main PCB
Driver PCB
3a
3b
Summary of Contents for DCP 8060
Page 19: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Page 28: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Page 65: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Page 92: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Page 95: ...Confidential 4 2 Cover page sample End page sample ...
Page 96: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 246: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 292: ...Confidential CHAPTER 7 CLEANING ...
Page 294: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Page 302: ...8 7 Confidential For white and black scanning a b c d e f g h i j ...
Page 314: ...8 19 Confidential Cover page sample End page sample Fig 8 10 ...
Page 323: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Page 458: ...B Power Supply PCB 100V Confidential ...
Page 459: ...B Power Supply PCB 200V Confidential ...
Page 495: ...January 06 SM FAX049 8C5B03 9 Printed in Japan ...