6-42
Confidential
<Installing Procedure>
(1) Put the Hook of the Separation pad ASSY MP into the MP feed frame and pull down the
Separation pad ASSY MP to the direction of the arrow 1b until it is locked.
Fig. 6-78
(2) Lift up the Lift arm MP and put the MP roller holder ASSY into the MP feed frame. Put the
Pin of the MP roller holder ASSY into the hole of the Lift arm MP.
Fig. 6-79
MP feed frame
Separation pad ASSY MP
MP frame
MP roller holder ASSY
MP feed frame
Lift arm MP
Pin
1a
1b
Hook
Hook