![Brother DCP 8060 Servise Manual Download Page 332](http://html.mh-extra.com/html/brother/dcp-8060/dcp-8060_servise-manual_53143332.webp)
Confidential
9-8
Error Code
(Hex)
Symptom Probable
Cause
Solution
Front open switch
broken
Replace the front open
switch.
A2
Document length exceeding
the scan limitation.
During scanning, 90 cm or
longer of a document is
detected.
During document feeding or
ejecting, 400 cm or longer of a
document is detected.
Document jam
Remove the jammed
document.
Document jam
Remove the jammed
document.
Document rear sensor
actuator caught on the
surrounding parts
Correct the surrounding
parts on which the
actuator caught.
A3
The document rear sensor does
not come ON during document
pull-in operation.
Document rear sensor
broken
Replace the document
rear sensor.
A4
50% or more faulty of white
level data. (Not used.)
A5
FAX scanning failure.
(1st time)
CCD defective
White-level reference
film stained in the
scanner cover
Replace the scanner cover
(scanner unit).
A6
FAX scanning failure. (retry)
Main PCB defective
Replace the main PCB.
A7-A9 Not
used.
AA
The document cover is opened
when the ADF is used.
Document cover sensor
defective
(Remove the document on
ADF, then close the
document cover.)
Replace the document
cover sensor.
AB Not
used.
AC
Less than 50% faulty of white
level data. (Not used.)
AD-AE Not
used.
Scanner lock lever is
not released.
Open the document cover
and release the scanner
lock lever.
Press the
[Stop/Exit]
key.
AF
The scanner is locked.
Scanner lock lever
defective
Replace the scanner lock
lever.
B0 Not
used.
CCD defective
Replace the CCD unit.
B1
Dark level offset data level
error for scanning.
Main PCB defective
Replace the main PCB.
CCD defective
Replace the CCD unit.
B2
Gain control data level error
for scanning.
Main PCB defective
Replace the main PCB.
Summary of Contents for DCP 8060
Page 19: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Page 28: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Page 65: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Page 92: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Page 95: ...Confidential 4 2 Cover page sample End page sample ...
Page 96: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 246: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 292: ...Confidential CHAPTER 7 CLEANING ...
Page 294: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Page 302: ...8 7 Confidential For white and black scanning a b c d e f g h i j ...
Page 314: ...8 19 Confidential Cover page sample End page sample Fig 8 10 ...
Page 323: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Page 458: ...B Power Supply PCB 100V Confidential ...
Page 459: ...B Power Supply PCB 200V Confidential ...
Page 495: ...January 06 SM FAX049 8C5B03 9 Printed in Japan ...