![Brother DCP 8060 Servise Manual Download Page 438](http://html.mh-extra.com/html/brother/dcp-8060/dcp-8060_servise-manual_53143438.webp)
App.
4-39
Confidential
WSW35
(Function setting 13)
Selector
No.
Function
Setting and Specifications
1
|
4
Max. detection period of dial
tone/busy tone during recording of
ICM (Not used.)
No. 1 2 3 4
0 0 0 0 : No
detection
0 0 0 1 : 1
sec.
0 0 1 0 : 2
sec.
0 1 0 0 : 4
sec.
|
|
1 1 1 1 : 15
sec.
5
|
8
Not used.
NOTE:
Selectors 1 through 4 are applicable to models equipped with internal TADs.
- Selectors 1 through 4: Max. detection period of dial tone/busy tone during recording of ICM
(Not used.)
If the machine (called station) detects dial tone or busy tone exceeding the detection level specified
by selectors 1 through 3 on WSW30 for the period specified by these selectors, then it disconnects
the line.
Summary of Contents for DCP 8060
Page 19: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Page 28: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Page 65: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Page 92: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Page 95: ...Confidential 4 2 Cover page sample End page sample ...
Page 96: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 246: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 292: ...Confidential CHAPTER 7 CLEANING ...
Page 294: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Page 302: ...8 7 Confidential For white and black scanning a b c d e f g h i j ...
Page 314: ...8 19 Confidential Cover page sample End page sample Fig 8 10 ...
Page 323: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Page 458: ...B Power Supply PCB 100V Confidential ...
Page 459: ...B Power Supply PCB 200V Confidential ...
Page 495: ...January 06 SM FAX049 8C5B03 9 Printed in Japan ...