204
Programmer
Chapter 4 Extended Option Output
Standard output
Condition
No.
Operation meeting the condition
30
After the work clamp is up (after the right work clamp is up for the air type)
31
After the work clamp is down
32
After the left work clamp is up (only for the air type)
33
After the left work clamp is down (only for the air type)
34
After the intermittent work clamp is up
35
After the intermittent work clamp is down
36
After the wiper output is off
37
After the thread trimmer output is off
38
Before the work clamp is up
Extended option external input
Condition
No.
Operation meeting the condition
40
When extended option input 1 is ON
41
When extended option input 1 is OFF
42
When extended option input 2 is ON
43
When extended option input 2 is OFF
44
When extended option input 3 is ON
45
When extended option input 3 is OFF
46
When extended option input 4 is ON
47
When extended option input 4 is OFF
48
When extended option input 5 is ON
49
When extended option input 5 is OFF
50
When extended option input 6 is ON
51
When extended option input 6 is OFF
52
When extended option input 7 is ON
53
When extended option input 7 is OFF
54
When extended option input 8 is ON
55
When extended option input 8 is OFF
56
When extended option input 9 is ON
Summary of Contents for BAS-300F Series
Page 7: ...6 Programmer Contents ...
Page 8: ...Chapter 1 Preparations of operation ...
Page 17: ...16 Programmer Chapter 1 Preparations of operation ...
Page 18: ...Chapter 2 Programming with Help Function ...
Page 85: ...84 Programmer Chapter 2 Programming with Help Function 4 Press Ending program 1 Press ...
Page 120: ...Chapter 3 Programming with Command Function ...
Page 195: ...194 Programmer Chapter 3 Programming with Command Function ...
Page 196: ...Chapter 4 Extended Option Output BAS 300 Series ...
Page 212: ...Chapter 5 Reading Writing Data ...
Page 224: ...Chapter 6 Preference ...
Page 226: ...Programmer 225 Chapter 6 Preference 5 After setting is complete press ...