Fabric OS Command Reference
917
53-1001764-01
slotPowerOff
22
slotPowerOff
Removes power from a slot.
SYNOPSIS
slotpoweroff
slot
DESCRIPTION
Use this command to turn off the power to a blade unit. The slot must have a valid blade unit present and
the blade unit must be of a type that can be powered off.
NOTES
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
OPERANDS
This command has the following operand:
slot
Specify the slot number of the blade to be powered down. This operand is
required.
EXAMPLES
To power off blade unit 3:
switch:admin>
slotpoweroff 3
Slot 3 is being powered off
SEE ALSO
powerOffListSet
,
powerOffListShow
,
slotPowerOn
,