background image

202

Fabric OS Command Reference

53-1001764-01

cryptoCfg

22

Rekey:                     disabled

Internal EE LUN state:     Encryption enabled

Encryption algorithm:      AES256-XTS

Key ID state:              Read write

Key ID:3a:21:6a:bd:f2:37:d7:ea:6b:73:f6:19:72:89:c6:4f

Key creation time:         Sun Jun 1 20:21:32 2008

New LUN:                   No

Replication LUN type:      Primary

Operation Succeeded

9.

Display Crypto LUN configuration. 

FabricAdmin:switch> 

cryptocfg --show -LUN 

 \

my_disk_tgt 0 10:00:00:00:c9:2b:c9:3a -cfg

EE node:               10:00:00:05:1e:41:9a:7e

EE slot:               0

Target:                20:0c:00:06:2b:0f:72:6d \

   20:00:00:06:2b:0f:72:6d

VT:                    20:00:00:05:1e:41:4e:1d \

   20:01:00:05:1e:41:4e:1d

Number of host(s):     1

Configuration status:  committed

Host:                  10:00:00:00:c9:2b:c9:3a \

   20:00:00:00:c9:2b:c9:3a

VI:                    20:02:00:05:1e:41:4e:1d \

   20:03:00:05:1e:41:4e:1d

LUN number:            0x0

LUN type:              disk

LUN status:            0

Encryption mode:       encrypt

Encryption format:     native

Encrypt existing data: disabled

Rekey:                 disabled

Key ID:                not available

Operation Succeeded

10. Display the zone configuration (note that a frame redirection zone has been created automatically to 

route traffic between host, VT, VI and target, VI, VT.) 

FabricAdmin:switch> 

cfgshow

Defined configuration:

 cfg:  itcfg     itzone

 cfg:    r_e_d_i_r_c__fg

 red_1109_brcd200c00062b0f726d200200051e414e1d; red_______base

 cfg:  testcfg1

                  testzone1

 zone: itzone 10:00:00:00:c9:2b:c9:3a; 20:0c:00:06:2b:0f:72:6d

 zone: red_1109_brcd200c00062b0f726d200200051e414e1d

         10:00:00:00:c9:2b:c9:3a; 20:0c:00:06:2b:0f:72:6d;

         20:02:00:05:1e:41:4e:1d; 20:00:00:05:1e:41:4e:1d

 zone: red_______base

           00:00:00:00:00:00:00:01; 00:00:00:00:00:00:00:02;

           00:00:00:00:00:00:00:03; 00:00:00:00:00:00:00:04

zone: testzone1

         1,0 

 

Effective configuration:

  cfg:  itcfg

  zone: itzone 10:00:00:00:c9:2b:c9:3a

               20:0c:00:06:2b:0f:72:6d

Summary of Contents for Brocade 8/12c

Page 1: ...53 1002147 01 29 April 2011 Fabric OS Command Reference Manual Supporting Fabric OS v7 0 0 ...

Page 2: ...t any time without notice and assumes no responsibility for its use This informational document describes features that may not be currently available Contact a Brocade sales office for information on feature and product availability Export of technical data contained in this document may require an export license from the United States government The authors and Brocade Communications Systems Inc...

Page 3: ...620 3891 2111 E mail china info brocade com Document Title Publication Number Summary of Changes Publication Date Fabric OS Reference v2 0 53 0001487 03 September 1999 Fabric OS Reference v2 2 53 0001558 02 May 2000 Fabric OS Reference v2 3 53 0000067 02 December 2000 Fabric OS Reference v3 0 53 0000127 03 July 2001 Fabric OS Reference v2 6 53 0000194 02 December 2001 Fabric OS Reference v3 0 v4 0...

Page 4: ...reface and RBAC AD table Appendix A Cosmetic edits throughout March 2008 Fabric OS Command Reference 53 1000599 03 Corrections and updates to 31 commands Removed Brocade Optional Features from Preface Added trademark note to Preface Cosmetic edits throughout July 2008 Fabric OS Command Reference 53 1001115 01 Added 3 new commands to support Encryption Modified 1 command Updated Preface and RBAC AD...

Page 5: ... and corrections January 2010 Fabric OS Command Reference 53 1001764 01 Added 8 new commands Modified 41 commands with new operands to support Fabric OS v6 4 0 features Removed 5 commands and 3 deprecated command options Miscellaneous edits to 100 additional commands to correct edits update examples etc Updated Preface surrounding chapters and permission tables March 2010 Fabric OS Command Referen...

Page 6: ...vi Fabric OS Command Reference 53 1002147 01 ...

Page 7: ...nventions xxx Notes cautions and warnings xxx Key terms xxx Notice to the reader xxxi Additional information xxxi Brocade resources xxxi Other industry resources xxxii Getting technical help xxxii Document feedback xxxiii Chapter 1 Using Fabric OS Commands In this chapter 1 Understanding role based access control 1 Understanding Virtual Fabric restrictions 2 Understanding Admin Domain restrictions...

Page 8: ...9 bottleneckMon 71 bpPortLoopbackTest 82 bpTurboRamTest 85 bufOpMode 87 ceePortLedTest 90 ceePortLoopbackTest 91 ceeTurboRamTest 92 cfgActvShow 93 cfgAdd 94 cfgClear 95 cfgCreate 96 cfgDelete 97 cfgDisable 98 cfgEnable 99 cfgRemove 100 cfgSave 101 cfgShow 102 cfgSize 104 cfgTransAbort 106 cfgTransShow 107 chassisBeacon 108 chassisDisable 109 chassisDistribute 110 chassisEnable 112 chassisName 113 ...

Page 9: ...gShow 213 defZone 214 diagClearError 216 diagDisablePost 217 diagEnablePost 218 diagHelp 219 diagPost 220 diagRetry 221 diagShow 222 distribute 223 dlsReset 225 dlsSet 226 dlsShow 229 dnsConfig 230 enclosureShow 231 errClear 233 errDelimiterSet 234 errDump 235 errFilterSet 237 errModuleShow 238 errShow 239 exit 241 fabRetryShow 242 fabricLog 244 fabricName 247 fabricPrincipal 249 fabricShow 252 fa...

Page 10: ...fcpLogShow 294 fcpProbeShow 295 fcpRlsShow 296 fcrBcastConfig 297 fcrChipTest 299 fcrConfigure 301 fcrEdgeshow 302 fcrFabricShow 304 fcrlSan 306 fcrLsanCount 308 fcrLsanMatrix 309 fcrPathTest 314 fcrPhyDevShow 317 fcrProxyConfig 319 fcrProxyDevShow 321 fcrResourceShow 323 fcrRouterPortCost 325 fcrRouteShow 327 fcrXlateConfig 328 fddCfg 331 fdmiCacheShow 333 fdmiShow 334 ficonCfg 335 ficonClear 336...

Page 11: ...eplace 384 fspfShow 385 fwAlarmsFilterSet 388 fwAlarmsFilterShow 389 fwClassInit 390 fwConfigReload 391 fwFruCfg 392 fwHelp 394 fwMailCfg 395 fwPortDetailShow 398 fwSamShow 401 fwSet 402 fwSetToCustom 403 fwSetToDefault 405 haDisable 407 haDump 408 haEnable 410 haFailover 411 haShow 412 haSyncStart 414 haSyncStop 415 help 416 h 418 historyLastShow 419 historyMode 420 historyShow 421 i 423 iclCfg 4...

Page 12: ...482 licenseIdShow 483 licensePort 484 licenseRemove 487 licenseShow 489 licenseSlotCfg 492 linkCost 496 login 498 logout 499 lsanZoneShow 500 lsCfg 502 lsDbShow 508 memShow 511 motd 512 msCapabilityShow 513 msConfigure 514 msPlatShow 516 msPlatShowDBCB 517 msPlClearDB 518 msPlMgmtActivate 519 msPlMgmtDeactivate 520 msTdDisable 521 msTdEnable 522 msTdReadConfig 523 myId 524 nbrStateShow 525 nbrStat...

Page 13: ...MonitorClear 570 perfMonitorShow 572 perfResourceShow 574 perfSetPortEEMask 577 perfShowAlpaCrc 579 perfShowPortEEMask 580 perfTTmon 582 policy 585 portAddress 588 portAlpaShow 591 portBeacon 592 portBufferShow 594 portCamShow 596 portCfg 598 portCfgAlpa 628 portCfgAutoDisable 629 portCfgCompress 632 portCfgCreditRecovery 634 portCfgDefault 635 portCfgDPort 637 portEncCompShow 639 portCfgEncrypt 6...

Page 14: ...tCfgQoS 679 portCfgShow 682 portCfgSpeed 695 portCfgTrunkPort 697 portCfgVEXPort 698 portCmd 701 portDebug 710 portDecom 711 portDisable 712 portDPortTest 714 portEnable 717 portErrShow 719 portFencing 721 portFlagsShow 724 portLedTest 726 portLogClear 728 portLogConfigShow 729 portLogDisable 730 portLogDump 731 portLogDumpPort 732 portLogEnable 733 portLogEventShow 734 portLoginShow 735 portLogPd...

Page 15: ...4 portTestShow 837 portThConfig 839 portTrunkArea 848 portZoneShow 853 powerOffListSet 854 powerOffListShow 856 psShow 857 roleConfig 858 reBoot 861 routeHelp 863 secActiveSize 864 secAuthSecret 865 secCertUtil 867 secDefineSize 876 secGlobalShow 877 secHelp 879 secPolicyAbort 880 secPolicyActivate 881 secPolicyAdd 882 secPolicyCreate 884 secPolicyDelete 887 secPolicyDump 889 secPolicyFCSMove 892 ...

Page 16: ...PortTest 949 supportFfdc 950 supportFtp 951 supportSave 953 supportShow 957 supportShowCfgDisable 960 supportShowCfgEnable 962 supportShowCfgShow 964 switchBeacon 966 switchCfgPersistentDisable 967 switchCfgPersistentEnable 968 switchCfgSpeed 969 switchCfgTrunk 970 switchDisable 971 switchEnable 972 switchName 973 switchShow 974 switchStatusPolicySet 987 switchStatusPolicyShow 990 switchStatusShow...

Page 17: ...ockServer 1031 tsTimeZone 1033 turboRamTest 1036 upTime 1037 uRouteConfig 1038 uRouteRemove 1039 uRouteShow 1040 usbStorage 1042 userConfig 1044 version 1052 wwn 1053 wwnAddress 1055 zone 1057 zoneAdd 1067 zoneCreate 1068 zoneDelete 1070 zoneHelp 1071 zoneObjectCopy 1072 zoneObjectExpunge 1073 zoneObjectRename 1075 zoneRemove 1076 zoneShow 1077 Chapter 3 Primary FCS Commands In this chapter 1079 P...

Page 18: ...xviii Fabric OS Command Reference 53 1002147 01 Contents Command validation checks 1081 Encryption commands and permissions 1082 General Fabric OS commands and permissions 1085 ...

Page 19: ...t is organized to help you find the information that you want as quickly and easily as possible The document contains the following components Chapter 1 Using Fabric OS Commands explains how to use the command line interface to manage a Brocade SAN and Brocade switches Chapter 2 Fabric OS Commands provides command information Chapter 3 Primary FCS Commands summarizes the subset of commands availab...

Page 20: ... switch Condor 2 Brocade 7800 Extension switch 8 Gbit 16 FC ports 6 GbE ports Goldeneye 2 Brocade 8000 FCoE switch 8 Gbit 16 FC port 10 Gbe 8 Ethernet port switch Anvil Condor 2 Brocade Encryption Switch 8 Gbit 16 port encryption switch Condor 2 DCX DCX 4S FC8 16 port blade FC8 32 port blade FC8 48 port blade FC8 64 port blade FC10 6 port blade FCOE10 24 DCX Blade FR4 18i Router blade FS8 18 Encry...

Page 21: ...fmConfig command Advanced Performance Monitoring APM frameLog Collects data about discarded Class 3 frames motd Sets the pre login banner on the chassis Security portCfgCompress Configures a port for inflight compression Inflight Encryption and Compression PortCfgDport Configures a port as a diagnostic port Fabric Services portCfgEncrypt Configures a port for encryption Inflight Encryption and Com...

Page 22: ...hanged to portttRes Deprecated legacy monitors and commands removed filter support from remaining performance monitor commands Bottleneck Monitoring New options to the bottleneckMon command to configure sub second thresholds bottleneckMon config lsubsectimethresh time_threshold bottleneckMon config lsubsecsevthresh severity_threshold Buffer Credit Loss Detection and Recovery The bottleNeckMon comm...

Page 23: ...f configured FabricShow Displays Fabric Name if configured Support FCP probing on NPIV devices fcpProbeShow Display the probing information for NPIV devices configure New configuration parameter Allow NPIV Probing Support for user defined port name portName Sets default port name up to 128 characters long Use the configure command to disable the feature The portShow command displays the port name ...

Page 24: ...ite and Byte streaming on FCIP tunnels are no longer supported IPv6 addresses are supported except for inband management interfaces The restrictions on addressing have been lifted An IPv4 subnet can span multiple GbE interfaces and you can now have multiple IPv6 addresses with the same prefix configured on different GbE interfaces on the same extension switch or blade Support for lossless failover...

Page 25: ...tion for 10G 16G platforms configDownload New protocol p sftp option to support secure FTP SFTP configUpload New protocol p sftp option to support secure FTP SFTP configureChassis New option to Add Suffix to the uploaded file name fimrwareDownload enhancements Ability to download firmware without a password New r option downloads firmware to the secondary partition only New protocol p sftp option ...

Page 26: ...dated as needed chassisShow configDefault configure dlsReset dlsSet dlsShow fanDisable fanEnable fcipChipTest fcipPathTest haDump haEnable haShow historyLastShow historyMode historyShow licenseSlotCfg lsCfg portAddress portCfgEXPort portCfgLongDistance LD values for new platforms portStatsShow portStats64Show portTrunkArea statsClear switchCfgSpeed Updated for 16G speeds portCfgSpeed Updated for 1...

Page 27: ...ports 1024 and above aaaConfig New nologout option protects existing sessions from termination when changing protocols secPolicyCreate DCC Policy lockdown does not work in switch disabled state secStatsShow Updated list of valid security policies sshUtil Modified to generate authentication keys for a specified use SNMP snmpConfig enhancements Support for new SW traps swStateChange swMovePort and s...

Page 28: ...iscsiSessionCfg iscsiSwCfg isnscCfg perfAddIPMonitor perfAddRWMonitor perfAddReadMonitor perfAddSCSIMonitor perfAddUserMonitor perfAddWriteMonitor perfClearFilterMonitor perfDelFilterMonitor perfShowFilterMonitor pkiShow pkiCreate pkirRemove secAuthCertificate switchSetFID userRename The following commands no longer support filter monitors perfCfgClear perfCfgSave perfMonitorClear perfMonitorShow ...

Page 29: ...ic page breaks in CLI command output displays are being phased out Use the more option to display command output with page breaks command more Do not use the more option in conjunction with help pages Executing help command more will display a command no manual entry for command message Document conventions This section describes text formatting conventions and important notices formats Text forma...

Page 30: ...d warnings The following notices and statements are used in this manual They are listed below in order of increasing severity of potential hazards NOTE A note provides a tip guidance or advice emphasizes important information or provides a reference to related information Regular help page notes are included under the NOTES side heading ATTENTION An Attention statement indicates potential damage t...

Page 31: ...in a user ID and password http my brocade com White papers online demonstrations and data sheets are available through the Brocade Web site at http www brocade com products solutions products index page For additional Brocade documentation visit the Brocade SAN Info Center and click the Resource Library location http www brocade com Release notes are available on the Brocade Web site Corporation R...

Page 32: ...ormed and the results Serial console and Telnet session logs syslog message logs 2 Switch Serial Number The switch serial number and corresponding bar code are provided on the serial number label as shown here The serial number label is located as follows Brocade 5100 5300 VA 40FC and Brocade Encryption Switch On the switch ID pull out tab located inside the chassis on the port side on the left Br...

Page 33: ...ompleteness of this document However if you find an error or an omission or you think that a topic needs further development we want to hear from you Forward your feedback to documentation brocade com Provide the title and version number and as much detail as possible about your issue including the topic heading and page number and your suggestions for improvement ...

Page 34: ...xxxiv Fabric OS Command Reference 53 1002147 01 ...

Page 35: ...ce to validate command execution and provides the RBAC permissions for the commands included in this manual Alternately you can use the classConfig command to display the RBAC permissions for any specified command or meta object format MOF class Refer to the classConfig command for more information TABLE 2 Role definitions Role Name Definition User Non administrative use such as monitoring system ...

Page 36: ...mation on configuring user account access permissions in a Virtual Fabric environment Any given role is allowed to execute all switch commands to which the role is authorized in the account s home context The default home context is the default logical fabric FID 128 You can change an account s home context to a specified FID and configure the account permissions to access additional logical switc...

Page 37: ...ssion Access is controlled by a switch level password for each access level The commands available through the CLI are based on the user s login role and the license keys used to unlock certain features The Fabric OS CLI provides the following capabilities Access to the full range of Fabric OS features given the license keys installed Assistance with configuration monitoring dynamic provisioning a...

Page 38: ...nd includes a synopsis of its syntax a description of command use and a set of examples The same information can be accessed by issuing help command on a Brocade switch or director This command displays the help page for the specified command For example to display the help page for ad type switch admin help ad ...

Page 39: ...LDAP servers are contacted in the order they appear in the configuration list The first server returning authentication success or failure causes the authentication request to succeed or fail If no response is received within the specified timeout the next RADIUS or LDAP server in the list is contacted An event entry logs if all RADIUS or LDAP servers fail to respond When the command succeeds it t...

Page 40: ...names shown in the current configuration The following options are supported conf radius ldap Specifies the server configuration as either RADIUS or LDAP This operand is required The following operands are optional p port Specifies the RADIUS or LDAP server port number Supported range is 1 to 65535 The default port is 1812 for RADIUS authentication The default port is 389 for LDAP authentication T...

Page 41: ...red to_position Specifies the new position for the server The value for to_position is an integer and must be within the range of server positions in the current configuration Use the show option to determine current server positions This operand is required authspec aaa1 aaa2 backup nologout Replaces the configuration with the specified AAA service Each service can be specified only once in the l...

Page 42: ...e of the primary AAA services are available nologout If nologout is not specified a change in the authentication mechanism may result in the termination of existing sessions All existing sessions are terminated if the new authentication mechanism is one of the following RADIUS only LDAP only or Local If nologout is specified there will be no effect on the existing sessions regardless of the chosen...

Page 43: ...uthentication mechanism with the no logout provision switch admin aaaconfig authspec radius nologout switch admin aaaconfig show RADIUS CONFIGURATIONS Position 1 Server 172 20 1 68 Port 1812 Secret testing123 Timeout s 3 Auth Protocol PEAP MSCHAPv2 LDAP CONFIGURATIONS LDAP configuration does not exist Primary AAA Service RADIUS Secondary AAA Service None SEE ALSO None ...

Page 44: ...ain operations This command follows a batched transaction model When executed with the activate add clear create deactivate delete remove rename options this command changes only the Defined Configuration in the transaction buffer The save option sends the changes made in the transaction buffer to all other switches and permanently saves the changes to the Defined configuration in persistent stora...

Page 45: ... may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS The generalized syntax for this command is ad action arguments Command actions are described first Argument details follow the description of actions The following actions are supported activate arg Activates an Admin Domain An Admin Domain is enforced only if it is in an activated...

Page 46: ...he command prompts for confirmation before executing the delete action The delete operation remains in the transaction buffer until you issue ad apply or ad save exec arguments This command performs the following tasks Creates a new shell Executes ad select to the specified Admin Domain Executes the specified commands Exits the shell remove arguments Removes one or more members from an Admin Domai...

Page 47: ...ain aware members All FC Router imported devices in the AD device list are marked as AD aware members transabort Aborts the transaction buffer The command prompts for confirmation before aborting the transaction transshow Displays the ID of the current Admin Domain transaction and indicates whether or not the transaction can be aborted The transaction cannot be aborted if it is an internal Admin D...

Page 48: ...closed in quotation marks Separate each entry in the switch list with a semicolon Specify the switch in one of the following formats Switch WWN World wide name of the switch Domain ID Any switch member specified in Domain ID format is converted into a switch WWN based on the current fabric information Operations with switch list fail if the domain ID to switch WWN lookup fails Membership in an AD ...

Page 49: ...n This action will trigger ad apply to all switches in the fabric Do you want to apply all admin domains yes y no n no y To clear all Admin Domain definitions switch admin ad clear You are about to delete all ADs definitions This operation will fail if zone configurations exists in AD1 AD254 Do you want to clear all admin domains yes y no n no y To create an Admin Domain with a mix of D PI WWNs an...

Page 50: ...e Eng_AD Eng_AD2 To rename AD 200 to Eng_AD200 switch admin ad rename 200 Eng_AD200 To rename a user assigned Admin Domain name to a reserved Admin Domain name this operation fails if AD_test s AD number is not 200 switch admin ad rename AD_test AD200 To remove the devices 100 5 and 1 3 from AD1 switch admin ad remove AD1 d 100 5 1 3 21 00 00 e0 8b 05 4d 05 To remove the switch 100 from AD1 switch...

Page 51: ...7 21 00 00 80 e5 12 8b 55 Switch port members 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 1 10 1 11 1 12 1 13 1 14 1 15 Switch WWN members 10 00 00 60 69 00 02 53 To display the AD1 configuration information in the transaction buffer switch admin ad show 1 m 0 Current AD 255 AD255 Transaction buffer configuration no configuration To display the AD10 configuration information in persistent storage swit...

Page 52: ...ansaction buffer configuration no configuration Defined configuration AD Number 1 AD Name AD1 State Inactive Device WWN members 10 00 00 00 00 01 00 00 10 00 00 00 00 04 00 00 10 00 00 00 00 05 00 00 10 00 00 00 00 06 00 00 10 00 00 00 00 08 00 00 10 00 00 00 00 03 00 00 10 00 00 00 00 02 00 00 10 00 00 00 00 07 00 00 10 00 00 00 00 15 00 00 10 00 00 00 00 16 00 00 10 00 00 00 00 17 00 00 10 00 00...

Page 53: ...min ad transabort You are about to abort the outstanding AD transaction Do you want to abort the AD transaction yes y no n no y To display the current Admin Domain transaction switch admin ad transshow Current transaction token is 26816 It is abortable switch admin ad transshow There is no outstanding zoning transaction SEE ALSO cfgSave cfgTransShow defZone logout ...

Page 54: ...t2 ag pgshow pgid ag pgcreate pgid N_Port1 N_Port2 n pgname m lb mfnm ag pgadd pgdel pgid N_Port1 N_Port2 ag pgrename pgid newname ag pgremove pgid ag pgmapadd pgmapdel pgid F_Port1 F_Port2 ag pgsetmodes pgdelmodes pgid mfnm lb ag pgfnmtov new_tov ag failoverenable failoverdisable N_Port pg pgid ag failovershow N_Port ag failbackenable failbackdisable N_Port pg pgid ag failbackshow N_Port ag prefs...

Page 55: ...ate of AG Configure and display F_Port to N_Port mapping Configure and display N_Port failover and failback policies Configure and display Port Group policy Create or remove a Port group Enable or disable auto port configuration APC modes for a Port group Get or set timeout value for fabric name monitoring Display Port Groups and member N_Ports Add or delete N_Ports in a Port group Display all pol...

Page 56: ...owing operands help Displays the command usage show Displays the current configuration of the Access Gateway This includes all N_Ports and F_Ports that are currently online failover and failback settings as well as any online F_Ports that are currently mapped to N_Ports Failover and failback policies are displayed as enabled 1 or disabled 0 modeshow Displays the current Access Gateway operating mo...

Page 57: ...t configuration policy When enabled this policy applies to all ports on the switch All F_Port to N_Port mapping and port group configurations are ignored ads Enables the advanced device security ADS policy When enabled this policy applies to all the ports on the switch By default all devices have access to the fabric on all ports wwnloadbalance Enables the device WWN load balancing policy When thi...

Page 58: ...tic mapping is enabled the F_Ports and all logged in devices will logout of the previous N_Port and login using the new N_Port staticdel N_Port F_Port1 F_Port2 Deletes a static mapping between an existing primary N_Port and one or more specified F_Ports This command removes exiting mappings Alternately you can remove an existing mapping by mapping the F_Port to another N_Port pgshow pgid Displays ...

Page 59: ...the port group are redistributed among the remaining F_Ports Similarly if an N_Port comes online port logins in the PG are redistributed to maintain a balanced N_Port to F_Port ratio This operation is disruptive Login balancing mode is disabled by default in all port groups mfnm Enables the managed fabric name monitoring mode MFNM in the specified port group This command changes the fabric name mo...

Page 60: ...online Only the originally mapped F_Ports fail back In the case of multiple N_Port failures only F_Ports that were mapped to the recovered N_Port experience failback The remaining F_Ports are not redistributed among the online N_Ports during the failback If preferred secondary F_Port to N_Port mapping is in place and the primary N_Port comes back online then the F_Ports are rerouted through the pr...

Page 61: ...ist with an asterisk to remove the specified WWNs from all the F_Ports allow lists ADS policy must be enabled for this command to succeed adsshow Displays the list of allowed device WWNs for all F_Ports persistentalpaenable 1 0 mode Configures the persistent ALPA feature Once enabled the ALPA parts of all device PIDs become persistent regardless of whether they were logged in before or after the p...

Page 62: ...ed in double quotation marks WWNs must be separated by semicolons The device WWN to port group mapping takes effect the next time the device logs in delwwnpgmapping PG WWN WWN2 all Removes the mapping between the specified device WWNs and the specified port group The port group is identified by its port group ID The all option removes the mapping of all device WWNs currently mapped to the specifie...

Page 63: ...h 100 The default value is 25 The port becomes reliable again if it does not receive any SCN messages for a period of five minutes Preferred N_Port settings are not enforced on unreliable N_Ports When the port becomes reliable again the behavior is as follows If a FAILBACK flag is set the port will fail back the configured F_Ports Configured F_Ports that are offline will come back online If LB mod...

Page 64: ...0a a3 90 3 1 To display the current Access Gateway mode switch admin ag modeshow Access Gateway mode is enabled switch admin ag modeshow Access Gateway mode is NOT enabled AG group policy commands To show current policies switch admin ag policyshow AG Policy Policy Name State Port Grouping pg Enabled Auto Port Configuration auto Disabled Advanced Device Security ads Disabled WWN Based Load Balanci...

Page 65: ...ic Current Failover Failback PG_ID PG_Name _F_Ports _F_Ports F_Ports 0 4 5 6 None 4 5 6 1 0 2 SecondFabric 1 7 8 9 None 7 8 9 0 1 0 pg0 2 10 11 None 10 11 1 0 2 SecondFabric 3 12 13 None 12 13 0 1 0 pg0 Explanation of fields in mapshow output Static F_Ports are part of as static F_Port to N_Port mapping Current F_Ports are the F_Ports that are currently online and mapped to a given N_Port either b...

Page 66: ...rt ERROR Unable to remove F_Port s from mapping retry the command switch admin ag prefshow F_Ports Preferred N_Port 10 11 0 4 5 6 2 7 8 9 3 switch admin ag prefdel 5 2 Preferred N_Port is deleted successfully for the F_Port s switch admin ag mapdel 2 5 F_Port to N_Port mapping has been updated successfully To create and display a static mapping switch admin ag staticadd 17 1 switch admin ag show N...

Page 67: ... a single port switch admin ag failoverenable 1 Failover policy is enabled for port 1 switch admin ag failoverdisable 0 Failover policy is disabled for port 0 switch admin ag failovershow 0 Failover on N_Port 0 is not supported switch admin ag failbackdisable 2 Failback policy is disabled for port 2 switch admin ag failbackshow 2 Failback on N_Port 2 is not supported switch admin ag failbackenable...

Page 68: ...g pgshow PG_ID PG_Name PG_Mode N_Ports F_Ports 0 pg0 lb mfnm 1 3 10 11 2 SecondFabric 0 2 4 5 6 To create a port group FirstFabric that includes N_Ports 1 and 3 and has login balancing enabled switch admin ag pgcreate 3 1 3 n FirstFabric1 m lb Port Group 3 created successfully switch admin ag pgshow PG_ID PG_Name PG_Mode N_Ports F_Ports 0 pg0 lb mfnm none none 2 SecondFabric 0 2 4 5 6 3 FirstFabri...

Page 69: ...orts F_Ports 0 pg0 lb mfnm 0 2 4 5 6 3 FirstFabric lb mfnm 1 3 10 11 To disable managed fabric name monitoring in port group 3 switch admin ag pgdelmodes 3 mfnm Managed Fabric Name Monitoring mode has been disabled for Port Group 3 switch admin ag pgshow 0 pg0 lb mfnm 0 2 4 5 6 3 FirstFabric lb 1 3 10 11 To get the current fabric name monitoring timeout value switch admin ag pgfnmtov Fabric Name M...

Page 70: ... Lists of the F_Port s To remove two devices from the lists of allowed devices for ports 1 and 9 switch admin ag adsdel 3 9 22 03 08 00 88 35 a0 12 22 00 00 e0 8b 88 01 8b WWNs removed successfully from Allow Lists of the F_Port s To add a two new device to the lists of allowed devices for ports 1 and 9 switch admin ag adsadd 3 9 20 03 08 00 88 35 a0 12 21 00 00 e0 8b 88 01 8b WWNs added successfu...

Page 71: ... device entry from the database when the device is offline switch admin ag deletepwwnfromdb 0 12 00 05 1e 85 92 88 Device 20 13 00 05 1e 85 92 88 successfully deleted To remove a device entry from the database when the device is not present in the table switch admin ag deletepwwnfromdb 0 12 00 05 1e 85 92 00 20 12 00 05 1e 85 92 00 not found Please check the device name To remove the PWWN to ALPA ...

Page 72: ... 25 f7 00 0c 29 00 04 8b 9 None None None yes 25 f7 00 0c 29 00 05 8b 9 None None None yes 25 f7 00 0c 29 00 07 8b 9 None None None yes 25 f7 00 0c 29 00 08 8b 9 None None None yes 25 f7 00 0c 29 00 09 8b 9 None None None yes 25 f7 00 0c 29 00 0a 8b 9 None None None yes Dynamic Device Mapping Information No dynamic mappings in use To display the WWN mappings when WWN load balancing policy is enabl...

Page 73: ...gin redistribution when F_Ports go offline Enable automatic login redistribution when N_Ports come online Use the show option to display the current configuration of the automatic rebalancing feature The command output varies depending on current AG policy settings If Port Group Policy is enabled on the switch the command displays the following information for each configured port group PG_ID Port...

Page 74: ... and disable options When a port group is specified command execution is targeted to the members of that specific port group When all port groups are specified command execution is targeted to all port groups defined in the Access Gateway The port group options are allowed only when login balancing is enabled on the specified port groups force Enforces automatic login redistribution on a one time ...

Page 75: ...agautomapbalance disable fport To enable automatic login redistribution on F_Ports and N_Ports on port group 1 in the Access Gateway switch admin agautomapbalance enable fport pg 1 To disable automatic login redistribution on F_Ports and N_Ports on all port groups in the Access Gateway switch admin agautomapbalance disable all SEE ALSO ag agShow ...

Page 76: ...d N_Ports that are online F Ports The number of F_Ports that are online Attached F Port information Displays the Port ID and the Port WWN of each F_Port that is online on the Access Gateway Access Gateway F Port information Displays the port number the port ID and the Port WWN of the Access Gateway to which the F_Port is connected This information is displayed only if both the Access Gateway and t...

Page 77: ...orts 8 F Ports 4 Attached F Port information PortID Port WWN 0x8ee801 20 03 00 05 1e af 77 82 0x8ee802 20 02 00 05 1e af 77 82 0x8ee803 20 01 00 05 1e af 77 82 0x8ee804 20 00 00 05 1e af 77 82 Access Gateway F Port Information F Port Number F Port ID F Port WWN 15 0x8ee601 20 0f 00 05 1e af 76 c2 14 0x8ee602 20 0e 00 05 1e af 76 c2 13 0x8ee603 20 0d 00 05 1e af 76 c2 12 0x8ee604 20 0c 00 05 1e af ...

Page 78: ...44 Fabric OS Command Reference 53 1001764 01 agShow 22 Local Remote Name local L5D_B10_4016_1 local L5D_B14_4024_1 local L5D_B13_200_AG SEE ALSO portCfgNPIVPort ...

Page 79: ...y be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details When an FCS policy is enabled this command can be issued only from the primary FCS switch OPERANDS The following operands are required aliName Specify the name of a zone alias enclosed in double quotation marks member Specify a member or list of members to be added to the alias enclosed in dou...

Page 80: ...A Command Availability for details When an FCS policy is enabled this command can be issued only from the primary FCS switch OPERANDS The following operands are required aliName Specify a name for the zone alias in double quotation marks A zone alias name must begin with a letter and can be followed by any number of letters numbers and underscore characters Names are case sensitive For example Ali...

Page 81: ...atile memory with the cfgSave command NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details When an FCS policy is enabled this command can be issued only from the primary FCS switch OPERANDS The following operand is required aliName Specify the na...

Page 82: ...y from the primary FCS switch OPERANDS This command has the following operands aliName Specify the name of the zone alias from which members are to be removed in double quotation marks This operand is required member Specify a member or list of members to be removed from the alias The list must be enclosed in double quotation marks Members must be separated by semicolons An alias member can be spe...

Page 83: ...CS switch OPERANDS When invoked without an operand this command displays all zone configuration information defined and effective Refer to cfgShow for a description of this display The following operands are optional pattern A POSIX style regular expression that matches zone alias names This operand must be enclosed in quotation marks Patterns may contain Question mark matches any single character...

Page 84: ...cy NOTES You must disable the switch before using this command to change the current policy Changes take effect immediately for all EX VEX_Ports after the switch is re enabled For details on performance tuning refer to the Fabric OS Administrator s Guide The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS C...

Page 85: ... Policy This policy dedicates some links to the ingress traffic and some links to the egress traffic This policy relieves internal congestion in an environment where there is a large amount of traffic going through both directions at the same time In addition it can reduce the impact of slow devices on the overall switch performance EXAMPLES To display the current APT policy switch admin aptpolicy...

Page 86: ...ons that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands class Configures filters for a specified audit class To add or remove any of the classes in the filter list reissue the class option audit_class Specifies the filters to be configured Valid values are 1 ZONE 2 SECURITY 3 CONFIGURATION...

Page 87: ... display the configuration switch admin auditcfg show Audit filter is enabled 1 ZONE 2 SECURITY 3 CONFIGURATION 4 FIRMWARE 5 FABRIC 6 FW 7 LS Severity level INFO To disable audit logging switch admin auditcfg disable Audit filter is disabled SEE ALSO auditDump ...

Page 88: ...mmand has the following operands s show Displays the audit log on the switch or the CP c clear Clears the audit log on the switch or the CP EXAMPLES To display the audit log switch admin auditdump s 0 AUDIT 2010 02 18 01 45 52 PDT SEC 3022 INFO SECURITY admin admin 10 32 220 161 http DCFM HttpConnec ad_0 ras035 FID 128 Event logout Status success Info Successful logout by user admin 1 AUDIT 2010 0...

Page 89: ...ent logical switch context In a VF environment authentication is performed only on physical E_Ports not on logical interswitch links LISLs NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands show ...

Page 90: ...authentication or the authentication policy is switched off off Turns the authentication policy off and the switch rejects any authentication requests active Sets the authentication policy to active mode During switch initialization authentication is initiated on all E_Ports but the port is not disabled if the connecting switch does not support authentication or the authentication policy is turned...

Page 91: ...play authentication configuration on the switch switch admin authutil show AUTH TYPE HASH TYPE GROUP TYPE fcap dhchap sha1 md5 0 1 2 3 4 Switch Authentication Policy PASSIVE Device Authentication Policy OFF To set DH CHAP as the authentication protocol switch admin authutil set a dhchap Authentication is set to dhchap To set both protocols in order of FCAP and then DH CHAP switch admin authutil se...

Page 92: ...008 03 24 23 13 06 AUTH 1003 112 INFO Stealth_3 Device authentication type has been successfully set to ON To start authentication on E F_Ports 2 3 and 4 switch admin authutil authinit 2 3 4 Warning Initiating the authentication requires either DH CHAP secrets or PKI certificates depending on the protocol selected Failed authentication may result in traffic disruption Authentication will not be in...

Page 93: ...um allowed the software truncates the input To close the banner text string enter a period at the beginning of a new line NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following optional operand banner Specify...

Page 94: ...al switch banner NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To display the banner for a switch switch admin bannershow Banner Do not disturb the setup on this switch SEE ALSO bannerSet motd ...

Page 95: ...the broadcast tree The broadcast routing information for the ports is displayed as a set of hexadecimal bit maps Each bit in a bit map represents a port with the least significant bit in each row representing port 0 32 64 and so on NOTES The output from this command may vary depending on the hardware platform The execution of this command is subject to Virtual Fabric or Admin Domain restrictions t...

Page 96: ...ollowing operands set mode Sets the GbE port mode for a specified slot Valid modes are one of the following 1g Enables the GbE ports ge0 ge9 xge0 and xge1 are disabled 10g Enables the GbE ports xge0 and xge1 ge0 ge9 ports are disabled dual Enables the GbE ports ge0 ge9 and xge0 xge1 is disabled slot slot Specifies the slot number for the FX8 24 blade This operand is required when setting the GbE p...

Page 97: ...lots switch admin bladecfggemode show all bladeCfgGeMode Blade in slot 1 is configured in 1GigE Mode 1GigE mode only the ge0 9 ports are enabled xge0 and xge1 are disabled bladeCfgGeMode Blade in slot 4 is configured in 10GigE Mode 10GigE mode only xge0 and xge1 are enabled ge0 9 ports are disabled SEE ALSO None ...

Page 98: ... blade when the blade is faulted powered off or running diagnostics This command disables the ports on a single blade To disable the ports in an entire chassis use the chassisDisable command NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OP...

Page 99: ...nc FC Disabled 399 5 15 cu 8G In_Sync FC Disabled 400 5 16 cu 8G In_Sync FC Disabled 401 5 17 cu 8G In_Sync FC Disabled 402 5 18 cu 8G In_Sync FC Disabled 403 5 19 cu 8G In_Sync FC Disabled 404 5 20 cu 8G In_Sync FC Disabled 405 5 21 cu 8G In_Sync FC Disabled 406 5 22 cu 8G In_Sync FC Disabled 407 5 23 cu 8G In_Sync FC Disabled 408 5 24 cu 8G In_Sync FC Disabled 409 5 25 cu 8G In_Sync FC Disabled ...

Page 100: ...n for online ports or to nonflashing amber for ports that do not initialize Disconnected ports remain unlit NOTES You cannot disable a single blade when the entire chassis is disabled or when the blade itself is faulted powered off or running diagnostics Use chassisEnable to enable the ports on an entire chassis Persistently disabled ports are not enabled by this command The execution of this comm...

Page 101: ...e 22 3 UNKNOWN VACANT 4 SW BLADE 2 ENABLED 5 CP BLADE 1 ENABLED 6 CP BLADE 1 ENABLED 7 SW BLADE 2 ENABLED 8 UNKNOWN VACANT 9 UNKNOWN VACANT 10 UNKNOWN VACANT SEE ALSO bladeDisable chassisDisable chassisEnable portEnable portDisable switchDisable switchShow ...

Page 102: ...esult of this operation is persistent across reboots and power cycles NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details This command leaves both the source and destination blades in a disabled state To enable all ports on a blade issue the bla...

Page 103: ...n restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands HBA_WWN Specifies the WWN of the HBA port connecting to the boot LUN This is a hexadecimal number for example 10 00 00 000 05 1e 41 9a cb PWWN Specifies the WWN of the remote storage target s port For example 50 00 00 05 1e...

Page 104: ... 00 00 00 aa bb cc dd 00 00 00 01 ee ff 11 22 00 00 00 02 9a bc 34 5f 00 00 00 03 a1 11 24 10 aa aa aa aa aa aa aa aa 00 00 00 00 11 11 11 11 00 00 00 01 11 11 11 11 00 00 00 02 9a bc 34 5f 00 00 00 03 a1 11 24 10 bb aa aa aa aa aa aa aa 00 00 00 00 11 11 11 11 00 00 00 01 11 11 11 11 00 00 00 02 9a bc 34 5f 00 00 00 03 a1 11 24 10 To remove an HBA to Port LUN mapping switch admin bootluncfg delet...

Page 105: ... Use this command to 1 detect latency and congestion bottlenecks on F L _Ports and E_Ports and 2 to manage credit recovery on back end ports Bottleneck detection and credit recovery are two independent functions enabling credit recovery has no impact on bottleneck detection and vice versa Bottleneck Detection For bottleneck detection this command provides the following management functions Enablin...

Page 106: ...e window of 30 seconds specifies that an alert should be sent when 80 of the one second samples over any period of 30 seconds were affected by latency bottleneck conditions The qtime option can be used to throttle alerts by specifying the minimum number of seconds between consecutive alerts Thresholds are configured separately for each type of bottleneck and statistical data are collected independ...

Page 107: ... congestion alert This threshold indicates the percentage of one second intervals affected by congestion conditions within a specified time window The congestion threshold is expressed as a fraction between 0 and 1 Latency threshold for alert The severity threshold for triggering a latency alert This threshold indicates the percentage of one second intervals affected by latency conditions within a...

Page 108: ...o Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details The bottleneck detection commands are supported on F_Ports FL_Ports E_Ports and EX_Ports The credit recovery commands are supported only on back end ports of Condor Condor 2 and Condor 3 based blades in the Brocade DCX DCX 4S DCX 8510 8 and ...

Page 109: ...y threshold for congestion that triggers an alert The threshold indicates the percentage of one second intervals affected by the bottleneck condition within the specified time window The threshold is expressed as the equivalent fraction between 0 and 1 The default value is 0 8 lthresh latency_threshold Specifies the severity threshold for latency that triggers an alert The threshold indicates the ...

Page 110: ...a bottleneck because of credit insufficiency The wildcard port specifier is allowed but not recommended Use disable to exclude all ports on the switch include slot port_list Includes previously excluded ports for bottleneck detection Previously configured switch wide alerts and threshold parameters reapply when bottleneck detection resumes The wildcard port specifier may be used as a shorthand for...

Page 111: ...the value of the interval cannot exceed 30 refresh Refreshes the display to continuously update with fresh data at a certain rate The refresh rate is equal to the number of seconds specified in the interval congestion latency Restricts the display to congestion or latency data If neither is specified the command displays combined statistics for both types of bottlenecks status Displays the details...

Page 112: ...ch admin bottleneckmon disable To display the number of ports affected by bottleneck conditions switch admin bottleneckmon show Fri Feb 26 22 00 00 UTC 2010 List of bottlenecked ports in most recent interval 13 16 Number of From To bottlenecked ports Feb 26 21 59 50 Feb 26 22 00 00 2 Feb 26 21 59 40 Feb 26 21 59 50 0 Feb 26 21 59 30 Feb 26 21 59 40 0 Feb 26 21 59 20 Feb 26 21 59 30 0 Feb 26 21 59 ...

Page 113: ...4 30 40 00 Jan 13 18 54 30 Jan 13 18 54 35 80 00 To display the bottleneck statistic for every port in the switch including the union of all individual port statistics switch admin bottleneckmon show interval 5 span 30 Wed Jan 13 18 54 35 UTC 2010 From To 0 1 2 3 4 5 Jan13 18 54 05 Jan13 18 54 10 20 00 20 00 0 00 80 00 20 00 100 00 From To 5 6 7 8 UNION Jan13 18 54 05 Jan13 18 54 10 40 00 0 00 0 0...

Page 114: ...shold for alert 0 100 Averaging time for alert 300 seconds Quiet time for alert 300 seconds Per port overrides for sub second latency bottleneck criterion Slot Port TimeThresh SevThresh 0 3 0 500 100 000 0 4 0 600 50 000 0 5 0 700 20 000 Per port overrides for alert parameters Slot Port Alerts LatencyThresh CongestionThresh Time s QTime s 0 1 Y 0 990 0 900 3000 600 0 2 Y 0 990 0 900 4000 600 0 3 Y...

Page 115: ...ttleneckmon cfgcredittools intport recover onLrThresh switch admin bottleneckmon showcredittools Internal port credit recovery is Enabled with LrOnThresh To disable back end port credit recovery and to display the configuration switch admin bottleneckmon cfgcredittools intport recover off switch admin bottleneckmon showcredittools Internal port credit recovery is Disabled SEE ALSO None ...

Page 116: ...ng command sequence 1 Execute chassisDisable 2 Execute slotStatsClear 3 Execute diagClearError all 4 Execute cryptoCfg disableEE if the encryption engine is in enabled state By default eight frames are transmitted and received on each port The test method is as follows 1 Set all ports present for the loopback mode specified 2 Create a frame F of maximum data size 2112 bytes 3 Transmit frame F thro...

Page 117: ...be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands slot slot Specifies the slot number on bladed systems nframes count Specifies the number of frames to send The test progresses until the specified number of frames has been transmitted on each port The default value is 8 pklen count Specifies the ...

Page 118: ...rrors were found in the ASIC statistics INIT Port failed to initialize PORTDIED A previously initialized port went to an un initialized state STATS Errors were found in the ASIC statistics TIMEOUT Did not receive a frame in the given timeout period XMIT Frame transmission failure EXAMPLES To run the test on blade ports 80 90 with one frame switch admin bpportloopbacktest bpports 80 90 nframes 1 Ru...

Page 119: ...FFFF pattern and write FFFF 0000 Subtest 3 turboram r m w inc 2 4 For each decrementing address read FFFF 0000 pattern and write 0000 FFFF Subtest 4 turboram r m w dec 1 5 For each decrementing address read 0000 FFFF pattern and write FFFF 0000 Subtest 5 turboram r m w dec 2 6 Repeat steps 1 5 with AAAA 5555 pattern NOTES This command is supported only on the Brocade Encryption Switch It complemen...

Page 120: ...ch admin bpturboramtest Running bpturboramtest Board Init Running Vader bist test Vader bist test PASSED Running Ob1 bist test Ob1 bist test PASSED BIST test PASSED on all ASIC s Test Complete bpturboramtest Pass 1 of 1 Duration 0 hr 1 min 55 sec 0 1 55 884 Cleaning up after test passed SEE ALSO turboRamTest ...

Page 121: ...mmands and Appendix A Command Availability for details This command is supported only on the Brocade FC8 16 FC8 32 and FC8 48 blades in a DCX or DCX 4S chassis An asterisk next to the slot configuration status indicates an unsupported blade Refer to the example section for an illustration This command is not supported on Control Processor CP blades and core blades OPERANDS This command has the fol...

Page 122: ...12 Buffer optimized mode is turned on for slot 11 switch admin bufopmode reset 12 Buffer optimized mode is turned off for slot 12 switch admin slotpoweron 11 switch admin slotpoweron 12 To display the changes switch admin bufopmode showall Slot 1 buffer optimized mode Off Slot 2 buffer optimized mode Off Slot 3 buffer optimized mode Off Slot 4 buffer optimized mode On Slot 9 buffer optimized mode ...

Page 123: ...mmand Reference 89 53 1001764 01 bufOpMode 22 Slot 11 buffer optimized mode Off Slot 12 buffer optimized mode Off indicates buffer optimization not supported on this blade SEE ALSO slotShow slotPowerOn slotPowerOff ...

Page 124: ...90 Fabric OS Command Reference 53 1001764 01 ceePortLedTest 22 ceePortLedTest DESCRIPTION See portLedTest SEE ALSO None ...

Page 125: ...Fabric OS Command Reference 91 53 1001764 01 ceePortLoopbackTest 22 ceePortLoopbackTest DESCRIPTION See portLoopbackTest SEE ALSO None ...

Page 126: ...92 Fabric OS Command Reference 53 1001764 01 ceeTurboRamTest 22 ceeTurboRamTest DESCRIPTION See turboRamTest SEE ALSO None ...

Page 127: ...ration The effective configuration is built when a specified zone configuration is enabled NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To display the effective zone configuration information switch admin cfgactvsho...

Page 128: ...abric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details When an FCS policy is enabled this command can be issued only from the primary FCS switch OPERANDS The following operands are required cfgName Specify a name for the zone configuration enclosed in double quotation marks member Specify a zone member or ...

Page 129: ...s subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details When an FCS policy is enabled this command can be issued only from the primary FCS switch OPERANDS None EXAMPLES To clear all zones and then clear nonvolatile memory switch admin cfgclear The Clear All action will clear all Aliase...

Page 130: ...d Availability for details When an FCS policy is enabled this command can be issued only from the primary FCS switch OPERANDS The following operands are required cfgName Specify a name for the zone configuration in double quotation marks A zone configuration name must begin with a letter followed by any number of letters numbers and underscores Names are case sensitive For example Cfg_1 and cfg_1 ...

Page 131: ...th the cfgSave command NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details When an FCS policy is enabled this command can be issued only from the primary FCS switch OPERANDS The following operand is required cfgName Specify a name for the zone c...

Page 132: ... the transaction was aborted If the default zone access mode is No Access then this command becomes equivalent to cfgEnable d_efault_Cfg Refer to defZone help for information on zone access configuration NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability f...

Page 133: ...ion of the defined and effective configurations NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details When an FCS policy is enabled this command can be issued only from the primary FCS switch OPERANDS The following operand is required cfgName Spec...

Page 134: ...ution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details When an FCS policy is enabled this command can be issued only from the primary FCS switch OPERANDS The following operands are required cfgName Specify a name for the zone configuration enclosed in double quo...

Page 135: ...ic when this command is run the transaction on the other switch is automatically aborted A message displays on the other switches to indicate that the transaction was aborted NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details When an FCS policy...

Page 136: ...d The devices that an initiator sees in the fabric are based on this configuration The effective configuration is built when a specific zone configuration is enabled and all error checking has been completed successfully When this command is executed after a zoning transaction was aborted on the local switch it displays the following warning message Warning Current Zoning Transaction was aborted R...

Page 137: ...ay1 21 00 00 20 37 0c 76 8c 21 00 00 20 37 0c 71 02 alias array2 21 00 00 20 37 0c 76 22 21 00 00 20 37 0c 76 28 alias loop1 21 00 00 20 37 0c 76 85 21 00 00 20 37 0c 71 df Effective configuration cfg USA_cfg zone Blue_zone 1 1 21 00 00 20 37 0c 76 8c 21 00 00 20 37 0c 71 02 1 2 21 00 00 20 37 0c 76 22 21 00 00 20 37 0c 76 28 zone Red_zone 1 0 21 00 00 20 37 0c 76 85 21 00 00 20 37 0c 71 df To dis...

Page 138: ...orage Committed size Displays the size of the defined configuration currently stored in nonvolatile memory Transaction size Displays the size of the uncommitted defined configuration This value will be nonzero if the defined configuration is being modified by Telnet API and so forth otherwise it is 0 Refer to the cfgShow help page for a description of defined and effective zone configurations Refe...

Page 139: ...Zone DB uncommitted space available 1041884 bytes Total AD and Zone Transaction buffer size 0 bytes AD Database Size committed 3124 bytes transaction 0 bytes Number of ADs in Effective Configuration 4 Each AD s Zone Database Size cfgsize Info for AD Number 0 AD Name AD0 State Active committed 242 bytes transaction 0 bytes cfgsize Info for AD Number 1 AD Name AD1 State Active committed 16 bytes tra...

Page 140: ...nd unaffected NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details When an FCS policy is enabled this command can be issued only from the primary FCS switch OPERANDS When invoked without an operand this command aborts the current transaction The ...

Page 141: ...ric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details When an FCS policy is enabled this command can be issued only from the primary FCS switch OPERANDS None EXAMPLES To display the current transaction switch admin cfgtransshow There is no outstanding zone transaction switch admin cfgclear Do you really wan...

Page 142: ...sed and only the beaconing pattern is shown Other commands are still executable and functional However if diagnostic frame based tests such as portLoopbackTest are executed the diagnostic LED pattern is interleaved with the beaconing pattern NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands...

Page 143: ...n error message if invoked while the chassis is enabled It is not necessary to disable a chassis before rebooting or powering off the switch To disable the ports of a single logical switch use the switchDisable command To disable the ports of a single blade use the bladeDisable command NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in plac...

Page 144: ... must be capable of accepting the distribution The distribution is aborted if one of the connected chassis or domains is configured to reject the distribution Use the fddCfg command to configure the fabric wide policies that control distribution behavior The command output includes the following information FID Indicates whether Virtual Fabrics are enabled or not on the domain that receives the di...

Page 145: ...st be separated by a semicolon A wildcard may be specified to include all switches in the fabric that support the distribute feature This operand is required and valid only when Virtual Fabrics are disabled force Distributes the database without confirmation EXAMPLES To distribute the IP Filter policies to all chassis that are connected through the logical fabric 128 and support the distribute fea...

Page 146: ... connected to multiple logical fabrics the logical switches rejoin their fabrics As each port is enabled the front panel LED changes from slow flashing amber to nonflashing green for online ports or to nonflashing amber for ports that do not initialize Disconnected ports remain unlit Loopback ports slowly flash green when online NOTES The execution of this command is subject to Virtual Fabric or A...

Page 147: ...bject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operand name Specify a new name for the chassis optionally in double quotation marks A chassis name can include up to 31 characters A chassis name must begin with a letter and can consist of let...

Page 148: ...hat supports real time power measurement When the capability is not supported for a FRU the line is suppressed Power Usage Watts 7 Factory part number up to 14 characters Factory Part Num xx xxxxxx xx 8 Factory serial number up to 12 characters Factory Serial Num xxxxxxxxxx 9 FRU manufacture date Manufacture Day dd Month mm Year yyyy 10 Date of the last FRU header update Update Day dd Month mm Yea...

Page 149: ...y Part Num 60 1002144 02 Factory Serial Num BQB0345F00G Manufacture Day 9 Month 11 Year 2010 Update Day 19 Month 2 Year 2011 Time Alive 41 days Time Awake 1 days SW BLADE Slot 2 Header Version 2 Power Consume Factor 180 Power Usage Watts 306 Factory Part Num 60 1002144 02 Factory Serial Num BQB0345F02R Manufacture Day 21 Month 11 Year 2010 Update Day 19 Month 2 Year 2011 Time Alive 41 days Time Aw...

Page 150: ...nder the MOF class Zoning but not to those under the UserManagement class The following RBAC permissions are supported in Fabric OS O observe OM observe modify N no access Note that the MOF class level permissions extend to all commands in that class but not necessarily to each and every command option For example a command may have the RBAC class permission of OM but a show only option under that...

Page 151: ...fig show classlist List of RBAC classes 1 AdminDomains 2 ADSelect 3 AG 4 APM 5 Audit 6 Authentication 7 Blade 8 ChassisConfiguration 9 ChassisManagement 10 ConfigManagement 11 Configure 12 DCE 13 Debug 14 Diagnostics 15 DMM 16 EncryptionConfiguration 17 EncryptionManagement 18 EthernetConfig 19 Fabric 20 FabricDistribution 21 FabricRouting 22 FabricWatch 23 Factory 24 FCoE 25 FICON 26 FIPSBootprom...

Page 152: ...ng To display the RBAC permissions for the commands included in the UserManagement class switch admin classconfig show UserManagement RBAC class Name UserManagement CLI Option Permission ldapcfg help O ldapcfg maprole OM ldapcfg show O ldapcfg unmaprole OM passwd OperandPresent OM passwdcfg disableadminlockout OM passwdcfg enableadminlockout OM passwdcfg help O passwdcfg set OM passwdcfg setdefaul...

Page 153: ...ave access to the RBAC class usermanagement are Role Name Permission Admin OM Factory OM Root OM SecurityAdmin OM To display the RBAC permissions for a command switch admin classconfig showcli classconfig CLI Option Permission RBAC Class classconfig help O RoleConfig classconfig show O RoleConfig classconfig showcli O RoleConfig classconfig showroles O RoleConfig SEE ALSO roleConfig ...

Page 154: ...strictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details This command cannot be executed on the standby CP OPERANDS None EXAMPLES To display the command history on a switch switch admin clihistory Dec 13 21 23 58 177 1 admin 10 120 35 35 version Dec 13 21 24 28 922 1 admin 10 120 35 35 help ag Dec 13 21 24 34 786 1 admin 10 120 35 ...

Page 155: ...wn down TenGigabitEthernet 0 3 unassigned administratively down down TenGigabitEthernet 0 4 unassigned administratively down down TenGigabitEthernet 0 5 unassigned administratively down down TenGigabitEthernet 0 6 unassigned administratively down down TenGigabitEthernet 0 7 unassigned administratively down down TenGigabitEthernet 0 8 unassigned administratively down down TenGigabitEthernet 0 9 una...

Page 156: ... add rule 2 switch admin config interface vlan 5 switch admin conf if vl 5 fcf forward switch admin conf if vl 5 exit switch admin config cee map test switch admin conf ceemap priority group table 1 weight 40 pfc switch admin conf ceemap priority group table 2 weight 60 switch admin conf ceemap priority table 2 2 2 1 2 2 2 2 switch admin conf ceemap exit switch admin config interface te 0 0 switch...

Page 157: ...esets the switch configuration only The fid option is not valid This command resets nonpersistent configuration parameters only The following parameters are not affected by this command Ethernet MAC address IP address subnet mask and boot ROM parameters IP gateway address License keys OEM customization Product ID and Vendor ID SNMP configuration System name Chassis name World wide name Zoning conf...

Page 158: ...issions all Restores all nonpersistent configuration parameters to factory default values switch and chassis parameters This command requires chassis permissions switch Resets the switch configuration only This operand is not valid in VF mode EXAMPLES To restore all system configuration parameters to default values switch admin configdefault all Executing configdefault Please wait Setting the defa...

Page 159: ... configuration parameters You must download both types of configuration data for the system to behave as expected You can use FTP or SCP to download configuration files from a remote host or you can retrieve the configuration files from a predetermined directory on the local system or from an attached USB device Use the vf option to download the Virtual Fabric configuration parameters The Virtual ...

Page 160: ...d on the switch When downloading the switch configuration the target FID must be defined in both the configuration download and the current system When downloading the switch configuration from a specified source FID to a target FID the target FID must be defined on the switch and the source FID and associated configuration must be defined in the configuration download In addition downloading an S...

Page 161: ...s then the following conditions apply The effective configuration remains as it was prior to the configuration download The enable action is ignored The Defined Configuration changes to reflect the new zoning configuration NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Com...

Page 162: ...termined directory on an attached USB device file Specifies the name of the configuration file to be downloaded This parameter can be used only with the local or USB option each of which retrieves files from a predetermined directory on the local chassis or on an attached USB device Therefore subdirectories and absolute path names are not permitted Quotation marks are optional force Overwrites an ...

Page 163: ...configDownload Switch is disabled configDownload complete All config parameters are downloaded To download the switch configuration data to the current logical switch from an external FTP server no chassis permissions switch admin configdownload ftp 192 168 38 245 jdoe config txt password To download all system configuration data for the chassis and all logical switches requires chassis permission...

Page 164: ...bject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands local Displays the list of configuration files on the local chassis USB U Displays the list of configuration files on the attached USB device EXAMPLES To display a list of configuration...

Page 165: ...ils OPERANDS This command has the following operands local Removes a configuration file that was previously created by configUpload local from the local chassis USB U Removes a configuration file that was previously created by configUpload USB from an attached USB device file Specifies the configuration file to be removed If the file option is omitted the command prompts for a file name EXAMPLES T...

Page 166: ...ssis configuration only The switch option displays the switch configuration only The fid option is not valid NOTES Not all values displayed are applicable to all system models and configurations The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPER...

Page 167: ...rtual Fabric enabled system switch admin configshow all Configuration upload Information Configuration Format 2 0 date Tue Oct 7 14 54 20 2008 FOS version v6 2 0 0 Number of LS 3 Chassis Configuration Begin fcRouting fcRoute backboneFabricId 100 fcRoute fcrState 2 fcRouteParam maxLsanCount 3000 fcRoute port 8 xportAdmin DISABLED fcRoute port 8 fabricId 4 fcRoute port 8 ratov 10000 fcRoute port 8 e...

Page 168: ...ult_ipv6 ipfilter 1 numofrules 12 ipfilter 1 rule 1 0 0x23 0 0 6 22 ipfilter 1 rule 10 0 0x23 0 0 17 123 ipfilter 1 rule 11 0 0x63 0 0 6 600 1023 ipfilter 1 rule 12 0 0x63 0 0 17 600 1023 ipfilter 1 rule 2 0 0x23 0 0 6 23 ipfilter 1 rule 3 0 0x23 0 0 6 897 ipfilter 1 rule 4 0 0x23 0 0 6 898 ipfilter 1 rule 5 0 0x23 0 0 6 111 ipfilter 1 rule 6 0 0x23 0 0 6 80 ipfilter 1 rule 7 0 0x23 0 0 6 443 ipfi...

Page 169: ...t device eth0 boot gateway ipa 10 32 224 1 Configuration acl clear 0 ag port nfportfailback 0x0 ag port nfportfailover 0x0 ag port nfporttopo 0 0x0 ag port nfporttopo 1 0x0 ag port nfporttopo 10 0x0 ag port nfporttopo 11 0x0 ag port nfporttopo 12 0x0 ag port nfporttopo 13 0x0 ag port nfporttopo 14 0x0 ag port nfporttopo 15 0x0 ag port nfporttopo 16 0x0 ag port nfporttopo 17 0x0 ag port nfporttopo ...

Page 170: ...force local USB U file DESCRIPTION This command uploads configuration data to a file Two types of configuration files can be uploaded with this command Virtual Fabric configuration parameters and system configuration parameters Use the vf option to upload Virtual Fabric configuration parameters The Virtual Fabric configuration includes logical switch definitions and Virtual Fabric status enabled o...

Page 171: ... to overwrite the file Specify force to overwrite the file without confirmation When the local chassis is chosen as the destination the resulting file is written to both primary and secondary partitions and on enterprise class platforms to both Active and Standby Control Processors CPs Refer to the Fabric OS Administrator s Guide for information on backward compatibility on configuration upload an...

Page 172: ...h the FTP server is running on Windows hosts This operand is valid only when the file is uploaded to an external host Quotation marks are optional passwd Specifies the account password Quotation marks are optional local Uploads a specified configuration file to a predetermined directory on the local chassis This option requires a file name USB U Uploads a specified configuration file to a predeter...

Page 173: ...rameters are uploaded To upload the configuration for the entire chassis to a local file from the command line forcing an overwrite switch admin configupload chassis local force config txt configUpload complete All config parameters are uploaded To upload the configuration for the current logical switch to an external FTP server switch admin configupload ftp 192 168 38 245 jdoe config txt password...

Page 174: ...rs can be set with the configure command Switch fabric parameters Virtual channel parameters F_Port login parameters Zoning operation parameters Remote State Change Notifications RSCN transmission mode Arbitrated Loop parameters System Services settings Portlog Events enable or disable settings Secure Socket Layer SSL attributes Remote Procedure Call Daemon RPCD attributes Web Tools attributes To ...

Page 175: ... Device Probing Boolean 0 0 or 1 Suppress Class F Traffic Boolean 0 0 or 1 Per frame Route Priority Boolean 0 0 or 1 Long Distance Fabric Boolean 0 0 or 1 BB Credit Number 16 1 to 27 Disable FID Check Boolean yes yes no Insistent Domain ID Mode Boolean no yes no Disable Default PortName Boolean no yes no Edge hold time Number 2 0 2 Fabric parameters are defined as follows Domain The domain number ...

Page 176: ...switch is enabled and is part of an edge fabric connected to an FCR this parameter cannot be turned on If the logical switch is disabled or it is not yet part of an edge fabric this parameter can be turned on However execution may cause edge fabric segmentation if the EX_Port connected to the edge fabric is disabled while the logical switch is enabled or connected to the edge fabric Disable FID Ch...

Page 177: ...e to set all the values within the range displayed against each parameter To reduce problems the configuration utility validates the modified parameter values and prompts you to re enter some values if the validation check fails Data Field Size The data field size specifies the largest possible value in bytes for the size of a type 1 data frame The switch advertises this value to other switches in...

Page 178: ...ameter Disable Default PortName When this mode is set the switch does not generate a default port name Edge hold time Configures the maximum time a frame can wait after it is received on the ingress port and before it is delivered to the egress port If the frame waits in the egress buffer for more than the configured hold time the switch drops the frame replenishes sender s credit and increments t...

Page 179: ...e v6 4 0 firmware versions the configured maximum is carried forward and may exceed the v6 4 0 limit It is recommended to reconfigure this parameter to be within the range permitted in Fabric OS v6 4 0 The following three parameters are related to staged F_Port logins by FLOGI requests and virtual device logins by FDISC SID 0 requests Logins per second Specifies the number of logins the switch acc...

Page 180: ...cation FAN frames be sent to public loop devices to notify them of their node ID and address When set to 1 frames are sent when set to 0 frames are not sent The default value is 1 Enable CLOSE on OPEN received If this is set a CLS is returned immediately to an OPN if no buffers are available This is required for TachLite The valid range is 0 to 4 The default value is 0 Always send RSCN Following t...

Page 181: ...s no Login Session Timeout number 200 60 to in seconds 432000 NOTES The maximum per port login limit is no longer configurable with this command Use the portcfgNPIVPort setloginlimit command to configure this parameter on a per port basis The Telnet interface is no longer configurable with this command Use the ipFilter command to enable or disable the Telnet interface The SNMP attributes are no lo...

Page 182: ...ssl attributes yes y no n no rpcd attributes yes y no n no webtools attributes yes y no n no switch admin switchenable To enable Dynamic Area Mode on the default partition of the Brocade DCX switch admin switchdisable switch admin configure Configure Change fabric parameters Y Domain 1 239 160 Enable 8 bit Dynamic Area Mode 0 No 1 Zero Based Area Assignment 0 1 0 1 R_A_TOV 4000 120000 10000 E_D_TO...

Page 183: ...stem services yes y no n no Portlog events enable yes y no n no ssl attributes yes y no n no rpcd attributes yes y no n no cfgload attributes yes y no n no webtools attributes yes y no n no SEE ALSO configDefault configShow configureChassis ipAddrSet portCfgLongDistance switchDisable switchEnable upTime ...

Page 184: ...a prompt with no preceding input the command accepts the default value if applicable and moves to the next prompt Interrupt Ctrl C Aborts the command immediately and ignores all changes made End of file Ctrl D When entered at a prompt with no preceding input terminates the command and saves changes made The following parameters can be modified with the configureChassis command Cfgload Attributes C...

Page 185: ... place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To enable signature validation for downloading firmware switch admin configurechassis Configure cfgload attributes yes y no n no y Enforce secure config Upload Download yes y no n no Enforce signature validation for firmware yes y no n no y Add Suffix to the uploaded file name ...

Page 186: ... all Password configUpload complete All selected config parameters are uploaded admin hq1 ls temp config config txt_Brocade5100_20110220_151606 admin hq1 date Sun Feb 20 15 17 14 UTC 2011 SEE ALSO configDefault configShow chassisEnable chassisDisable configure ipAddrSet portCfgLongDistance switchDisable switchEnable upTime ...

Page 187: ...efer to the Fabric OS Encryption Administrator s Guide NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details CAUTION When configuring a LUN with multiple paths there is a considerable risk of ending up with potentially catastrophic scenarios where...

Page 188: ...addr cryptocfg zeroizeEE slot cryptocfg delete file local_name cryptocfg reg KAClogin primary secondary cryptocfg show file all cryptocfg show localEE cryptocfg rebalance slot cryptocfg kvdiag enable disable show interval interval type type DESCRIPTION Use the node configuration commands to perform node initialization and configuration tasks Node initialization and configuration must be performed ...

Page 189: ...e Media Type TAPE DISK DISK TAPE or NOT DEFINED Rebalance Recommended No Yes or EE Busy unspecified try again to determine rebalance recommendation System Card Label Displayed only if a system card is registered System Card CID Displayed only if a system card is registered Remote EE Reachability If the EE is part of an encryption group the following information is displayed for the peer Node WWN S...

Page 190: ... the key vault to regenerate the Trusted Link after initializing the encryption engine The initnode function must be performed before the initEE function may be performed slot Specifies the slot number of the encryption engine to be initialized This operand is required on bladed systems regEE Registers a previously initialized encryption engine with the CP or chassis The CP and the specified encry...

Page 191: ...fied certificate to a mounted USB storage device When usb is specified the following operands are required dest_filename Specifies the name of the file on the USB device to which the file is to be exported The file is stored in a predetermined default directory on the storage device Specify one of the following certificates to be exported Certificates must be specified by file type Referring to ce...

Page 192: ...es the name to be assigned to the imported file This is a user generated file name source_filename Specifies the name of the certificate on the USB storage device from which you are importing reg membernode Registers a member node with the group leader This command is valid only on the group leader The encryption group must have been created prior to performing member node registration All member ...

Page 193: ...ntication is enabled Quorum Size is 0 this operation requires authentication of a quorum of authentication cards vault_IP_addr Specifies the IP address of the NetApp LKM appliance This operand is required zeroizeEE Zeroizes all critical security parameters on the local encryption switch or blade including all data encryption keys This command is valid on all nodes This operation causes the encrypt...

Page 194: ...ughput Rebalancing is recommended after containers have been added removed moved failed over and failed back This is a disruptive operation You may have to restart backup applications after rebalancing is complete Optionally specify a slot number on bladed systems kvdiag enable Enables the keyvault diagnostics When enabled this command checks connectivity configuration parameter retrieval and read...

Page 195: ...n succeeded To register an encryption engine with the CP or chassis SecurityAdmin switch cryptocfg regEE Operation succeeded To enable an encryption engine SecurityAdmin switch cryptocfg enableEE Operation succeeded To disable an encryption engine SecurityAdmin switch cryptocfg disableEE Operation succeeded To export a KAC certificate from the group leader to an external host SecurityAdmin switch ...

Page 196: ...U SURE yes y no n no y Operation succeeded To delete a file from the local node SecurityAdmin switch cryptocfg delete file etc fabos certs sw0 foo pem This will permanently delete the selected file ARE YOU SURE yes y no n no y To display local encryption engine information for a Brocade FS8 18 encryption blade on a DCX SecurityAdmin switch cryptocfg show localEE EE Slot 1 SP state Online Primary L...

Page 197: ...2 72 62 EE_STATE_ONLINE Reachable 10 00 00 05 1e 47 30 00 1 10 32 72 104 EE_STATE_ONLINE Reachable 10 00 00 05 1e 47 30 00 3 10 32 72 105 EE_STATE_ONLINE Reachable 10 00 00 05 1e 47 30 00 10 10 32 72 106 EE_STATE_ONLINE Reachable 10 00 00 05 1e 47 30 00 12 10 32 72 107 EE_STATE_ONLINE Reachable output truncated To rebalance load between tape and disk LUNS for optimal performance on slot 1 switch a...

Page 198: ...tocfg help groupcfg cryptocfg create encgroup encryption_group_name cryptocfg delete encgroup encryption_group_name cryptocfg reg keyvault cert_label certfile hostname ip_address primary secondary cryptocfg dereg keyvault cert_label cryptocfg reg KACcert signed_certfile primary secondary cryptocfg set keyvault LKM RKM SKM TEMS cryptocfg set failbackmode auto manual cryptocfg set hbmisses value cry...

Page 199: ...figuration data to the member nodes in the encryption group The groupCfg commands include three display options that show group configuration runtime status and group member information Refer to the Appendix of the Fabric OS Encryption Administrator s Guide for a more comprehensive explanation of system states Use the show groupcfg command to display encryption group and member configuration param...

Page 200: ...e Node WWN Encryption group state CONVERGED Encryption group formed successfully CONVERGING Encryption group partially formed member nodes may still be in discovery process DEGRADED Nodes lost connection with the group For each node in the encryption group the following information is displayed Node name the node WWN IP address the node IP address Role GroupLeader or MemberNode Use the show groupm...

Page 201: ...nterface and also configure a gateway for these I O sync links Refer to the ipAddrSet help page for instructions on configuring the Ethernet interface These I O sync link connections must be established before you enable the EEs for encryption If these configuration steps are not performed you cannot create an HA cluster perform a first time encryption or initiate a rekeying session OPERANDS The c...

Page 202: ...ip_address is the virtual IP address for the RKM cluster and not the address of the actual key vault primary secondary Specifies the key vault as either primary or secondary The secondary key vault serves as backup dereg keyvault Removes the registration for a specified key vault The key vault is identified by specifying the certificate label Removing a key vault registration disconnects the key v...

Page 203: ...tbeat misses allowed in a node that is part of an encryption group before the node is declared unreachable This value is set in conjunction with the time out value It must be configured at the group leader node and is distributed to all member nodes in the encryption group The following operand is required value Specifies the number of heartbeat misses The default value is 3 The range is 1 to 15 i...

Page 204: ...r node from the existing encryption group The node is specified by its node WWN This command is valid only on the group leader The node must be online in DISCOVERED state for this command to succeed To remove a node that is not online in DISCOVERING State use the dereg membernode command You must remove the EEs from the HA cluster and delete any Crypto Target container LUN configurations from this...

Page 205: ...mmand is valid only on the group leader This command prompts for a pass phrase passphrase Specifies the pass phrase for recovering the master key The pass phrase must be the same that was used to back up the master key with the exportmasterkey command currentMK alternateMK Specifies whether the master key should be restored to the current position or the alternate position This command replaces th...

Page 206: ...ther members The new group leader s database information may be different from what was set up before the group leader was rebooted sync securitydb Distributes the security database from the group leader node to all member nodes This operation can resolve problems with master key propagation The synchronization occurs every time this command is executed regardless of whether or not the security da...

Page 207: ...leave the encryption group SecurityAdmin switch cryptocfg leave_encryption_group Leave node status Operation Succeeded To generate the master key RKM on the group leader SecurityAdmin switch cryptocfg genmasterkey Master key generated The master key should be exported before further operations are performed To export the master key to the RKM key vault SecurityAdmin switch cryptocfg exportmasterke...

Page 208: ...4 29 61 9c 99 44 a3 9b 98 e3 ae aa 89 ec 12 0c 04 29 61 9c 99 44 a3 9b 99 Operation Succeeded To display the encryption group configuration SecurityAdmin switch cryptocfg show groupcfg Encryption Group Name system_test Failback mode Auto Replication mode Disabled Heartbeat misses 3 Heartbeat timeout 2 Key Vault Type LKM System Card Disabled Primary Key Vault IP address 10 32 49 200 Certificate ID ...

Page 209: ... 40 22 00 10 32 72 74 MemberNode EE Slot 1 SP state Online EE Slot 2 SP state Online EE Slot 4 SP state Online EE Slot 9 SP state Online 10 00 00 05 1e 53 6b 62 10 32 72 40 MemberNode current node EE Slot 0 SP state Waiting for enableEE 10 00 00 05 1e 54 22 36 10 32 72 61 GroupLeader EE Slot 0 SP state Online 10 00 00 05 1e 47 30 00 10 32 72 10 MemberNode EE Slot 1 SP state Online EE Slot 3 SP sta...

Page 210: ... 00 00 00 00 00 00 00 00 00 00 00 00 00 EE Slot 0 SP state Unknown State Current Master KeyID 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Alternate Master KeyID 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 No HA cluster membership No HA cluster membership To set the failback mode to manual failback SecurityAdmin switch cryptocfg set failbackmode manual Set failback policy status Operation S...

Page 211: ...iguration When invoked on the group leader both defined and committed configuration data is displayed including the following parameters Encryption group name A user defined name Number of HA clusters in the existing encryption group numeric value For each HA cluster HA cluster name user defined label Number of encryption engine entries numeric value HA cluster Status Committed or Defined For each...

Page 212: ...ers from an already configured HA cluster This command is valid only on the group leader This command only removes the failover failback capability for the removed EEs it does not affect the relationship between configured CryptoTarget containers and the encryption engine that is removed from the HA cluster The containers still belong to this encryption engine and encryption operations continue Th...

Page 213: ...ES To display existing HA clusters in the encryption group brocade the encryption group in the example has one committed HA cluster with one encryption engine SecurityAdmin switch cryptocfg show hacluster all Encryption Group Name brocade Number of HA Clusters 1 HA cluster name HAC1 1 EE entry Status Committed WWN Slot Number Status 11 22 33 44 55 66 77 00 0 Online To create a second HA cluster wi...

Page 214: ...er HAC1 Delete HA cluster status Operation succeeded To commit the changes SecurityAdmin switch cryptocfg commit Operation Succeeded To view the changes SecurityAdmin switch cryptocfg show hacluster all Encryption Group Name brocade_1 Number of HA Clusters 1 HA cluster name HAC2 1 EE entry Status Defined WWN Slot Number Status 10 00 00 05 1e 39 53 67 0 Online To initiate a manual failback of an en...

Page 215: ...isable enable read_ahead disable enable cryptocfg modify LUN crypto_target_container_name LUN_Num initiator_PWWN encryption_format native DF_compatible encrypt cleartext enable_encexistingdata disable_encexistingdata enablerekey time_period disable_rekey write_early_ack disable enable read_ahead disable enable cryptocfg remove LUN crypto_target_container_name LUN_Num initiator_PWWN cryptocfg enabl...

Page 216: ... cryptocfg reclaimWWN EE node_WWN slot list cryptocfg reclaimWWN cleanup DESCRIPTION Use these cryptoCfg commands to configure and manage tape or disk devices that store the encrypted and compressed data A CryptoTarget container CTC is a configuration of virtual devices that is created for each target port hosted on a Brocade Encryption Switch or FS8 18 blade The container holds the configuration ...

Page 217: ...tion or a split EG or if you intend to remove an FS8 18 Encryption blade from an encryption group In addition this command set includes the following display commands Output may vary depending on your configuration Refer to the Appendix of the Fabric OS Encryption Administrator s Guide for a more comprehensive explanation of system states Use the show container all stat command for runtime status ...

Page 218: ...ser defined label Number of containers numeric value For each container Container name a user defined label Type tape or disk EE node the node WWN EE slot numeric value Target target port WWN node WWN VT virtual target port WWN node WWN Number of hosts numeric value Configuration status committed or defined For each host the host port WWN and the node WWN For each VI the virtual initiator port WWN...

Page 219: ...for a listing of Crypto LUN status or configuration information for a specific CTC When used with stat the display includes the following LUN runtime status information Container name user defined label Type disk or tape EE node node WWN EE slot EE slot number Target target port WWN and node WWN Target PID VT virtual target port WWN and node WWN VT PID virtual target PID Number of hosts numeric va...

Page 220: ...s key life for LUNs that are currently being rekeyed and after the rekey is complete The remaining Key life period is displayed in the following format num_yrs num_months num_days num_minutes When used with cfg the show LUN command displays LUN configuration information EE node node WWN EE slot slot number Target target port WWN and node NWWN VT virtual target port WWN and node WWN Number of hosts...

Page 221: ...ode WWN Target PID target PID VT virtual target port WWN and node WWN VT PID virtual target PID Host initiator PWWN Host initiator node WWN Host initiator PID hoist PID VI virtual initiator port WWN and node WWN VI PID virtual initiator PID LUN Number numeric identifier LUN Serial Number alpha numeric identifier Percentage complete numeric value Rekey state displays one of the following parameters...

Page 222: ...rocessed Rekey Role Primary Or Backup Use the show tape_sessions command to display all tape sessions in progress on the local node or for a specific container The display includes the following information Number of tape sessions in progress numeric value Container name user defined label EE node name node WWN EE Slot Number slot number Target target port WWN and node WWN Target PID Target PID VT...

Page 223: ...ated and for each initiator that has the access to the target port one virtual initiator VI is created These virtual devices are created by logging into the fabric and registering with the Name Server Initiator and target must be zoned for NS based frame redirection to take effect Use the nsShow command to verify the creation of the virtual devices Use the cfgShow command to view the redirection z...

Page 224: ...n engine or the new encryption engine are offline This command is valid only on the group leader The following operands are required current_node_WWN current_slot Specifies the node WWN of the current encryption engine to which failover occurred earlier and which is now performing all encryption tasks On bladed systems specify the slot number of the current encryption engine new_node_WWN new_slot ...

Page 225: ...um number of LUNs you can add in one commit operation is 25 There is a delay of five seconds for each commit operation This command is valid only on the group leader The following operands are supported crypto_target_container_name Specifies the name of the CTC to which the LUN is added This operand is required LUN_Num LUN_Num_Range Specifies the LUN number or a range of LUN numbers These operands...

Page 226: ...aFort compatible license to be present on the encryption switch or the chassis that houses the encryption blade encrypt cleartext Enables or disables the LUN for encryption By default cleartext is enabled no encryption When the LUN policy is changed from encrypt to cleartext the following policy parameters become disabled default and generate errors when executed enable_encexistingdata enable_reke...

Page 227: ...her as a 16 bit 2 bytes number in hex notation for example 0x07 or as a 64 bit 8 bytes number in WWN format for example 0 07 00 00 00 00 00 00 The LUN number must be zero when a tape LUN is specified and the tape drive is a single LUN device When specifying a range the LUN numbers must be entered in the 16 bit hex format initiator_PWWN initiator_NWWN Specifies the initiator by its port WWN and nod...

Page 228: ... switch that is hosting the LUN No commit is required after executing this command This command proceeds with a warning and prompts for confirmation A LUN may become disabled for various reasons such as a change in policy from encrypted to cleartext a conflict between LUN policy and LUN or a missing DEK in the key vault Force enabling a LUN while metadata exist on the LUN may result in a loss of d...

Page 229: ...lt cleartext is enabled key_lifespan time_in_days none Specifies the lifespan of the encryption key in days The key expires after the specified number of days The default value is none which means the key does not expire until the value is set This parameter cannot be modified for tape pools once it is set delete tapepool Deletes the specified tape pool This command is valid only on the group lead...

Page 230: ...ded period of time include_mirror Initiates a manual rekey operation on all primary LUNs and mirror LUNs in read only state In addition this command also starts a manual rekey operation on all primary and nonreplicated LUNs in read write state resume_rekey Resumes a suspended rekey session for a specified disk LUN at the termination point A rekey session may terminate prematurely due to unrecovera...

Page 231: ...ays configuration information for all configured tape pools in the encryption group all stat Displays runtime status information for all configured tape pools in the encryption group label pool_label num pool_num Displays tape pool configuration or runtime status information for a single tape pool specified either by a tape pool label or a number These operands must be used with either the stat or...

Page 232: ...ncompressed blocks and or byte counters for the specified containers Specify one of the following operands all Clears blocks and or byte counters for all CryptoTarget tape containers crypto_target_container_name Clears blocks and or byte counters for all CryptoLUNs of the specified CryptoTarget tape container clearstats LUN Clears compressed or uncompressed blocks and or byte counters for a specif...

Page 233: ...on engines in the specified member node It also displays a list of containers that will be affected by the reclaim operation EE node_WWN slot Specifies the node WWN of any encryption engine in the encryption group This command frees up all WWNs associated with the specified encryption engines for reallocation You must specify a slot number in addition to the EE node WWN To complete the reclaiming ...

Page 234: ...figuration This action will replace the old zoning configuration with the current configuration selected Do you want to enable itcfg configuration yes y no n no y zone config itcfg is in effect Updating flash 2 Create a disk CryptoTarget container to be hosted on the encryption engine FabricAdmin switch cryptocfg create container disk my_disk_tgt1 0 00 00 05 1e 41 9a 7e 20 0c 00 06 2b 0f 72 6d 20 ...

Page 235: ... 00 00 c9 2b c9 3a 20 00 00 00 c9 2b c9 3a lunstate cleartext encrypt Operation Succeeded 7 Commit the device configuration FabricAdmin switch cryptocfg commit Operation Succeeded 8 Display Crypto LUN runtime status FabricAdmin switch cryptocfg show LUN my_disk_tgt 0 10 00 00 00 c9 2b c9 3a stat Container name my_disk_tgt Type disk EE node 10 00 00 05 1e 41 9a 7e EE slot 0 E hosting container curr...

Page 236: ...e 1d LUN number 0x0 LUN type disk LUN status 0 Encryption mode encrypt Encryption format native Encrypt existing data disabled Rekey disabled Key ID not available Operation Succeeded 10 Display the zone configuration note that a frame redirection zone has been created automatically to route traffic between host VT VI and target VI VT FabricAdmin switch cfgshow Defined configuration cfg itcfg itzon...

Page 237: ... Target 50 01 10 a0 00 8c 28 ba 50 01 10 a0 00 8c 28 b9 VT 20 08 00 05 1e 53 8a 24 20 09 00 05 1e 53 8a 24 Number of host s 1 Configuration status committed Host 10 00 00 05 1e 53 68 28 20 00 00 05 1e 53 68 28 VI 20 0a 00 05 1e 53 8a 24 20 0b 00 05 1e 53 8a 24 Number of LUN s 1 To display all configured tape pools FabricAdmin switch cryptocfg show tapepool all Tape pool label tpool 00001 Key life ...

Page 238: ...ption algorithm AES256 XTS Key ID state Re key Key ID eb d0 48 ce e9 f2 40 89 da d4 7e 10 18 72 fa 15 Key creation time Fri May 16 02 03 48 2008 Key life 300 days Rekey status 0 Key expiration time Sun May 18 04 03 48 2008 Operation Succeeded To display CryptoTarget container configuration information For a disk LUN with rekeying enabled FabricAdmin switch cryptocfg show LUN my_disk_tgt 0x0 10 00 ...

Page 239: ... Number of compressed bytes 1138031028 LUN number 0x1 Tape session number 1 Number of uncompressed blocks 0 Number of compressed blocks 0 Number of uncompressed bytes 0 Number of compressed bytes 0 Operation succeeded To reclaim all WWNs associated with an encryption engine switch admin cryptocfg reclaimWWN EE 10 00 00 05 1e 39 b3 96 12 Warning WWN reclaim operation may result in momentary IO disr...

Page 240: ...ners using the reclaimed WWN base 1 H183SB182_1 2 H183SB182_2 3 H183SB182_3 4 H183SB182_4 5 H183SB182_5 6 H183SB182_6 Operation succeeded To clean up the stale crypto configurations from the ejected member node switch admin cryptocfg reclaimWWN cleanup Warning There are stale Container HA Tape cryptodb configurations Please confirm to delete them ARE YOU SURE yes y no n no y Warning These are the ...

Page 241: ...status completed or pending the transaction ID and the transaction owner CLI or DCFM FUNCTION 6 Device decommissioning SYNOPSIS cryptocfg help decommission cryptocfg decommission container container_name initiator initiatator _PWWN LUN LUN_num cryptocfg delete decommissionedkeyids cryptocfg show decommissionedkeyids cryptocfg show vendorspecifickeyid key_ID DESCRIPTION Use these cryptoCfg commands...

Page 242: ...ere is no need to execute a decommissioning operation separately for each path associated with the LUN A commit operation is not required The following operands are required container container_name Specifies the name of the container that hosts the LUN initiator initiatator_PWWN Specifies the initiator port WWN LUN LUN_num Specifies the number of the LUN to be decommissioned delete decommissioned...

Page 243: ... 34 6e 44 cc 35 e9 be 71 64 ca 5e 90 switch admin cryptocfg show vendorspecifickeyid aa 8b 91 b0 35 6f da 92 8a 72 b3 97 92 1b ca b4 uuid b7e07a6a db64 40c2 883a 0bc6c4e923e6 3 Manually delete the keys from the vault This step requires accessing the Key Vault GUI and deleting the keys manually 4 Delete the key IDs from the internal cache switch admin cryptocfg delete decommissionedkeyids operation...

Page 244: ...5 ea 15 ea 15 ea 15 ea 15 ea 15 ea WORD_NOT 5 0015 ffea 0015 ffea 0015 ffea 0015 ffea QUAD_NOT 6 00000015 ffffffea 00000015 ffffffea BYTE_RAMP 7 15 16 17 18 19 1a 1b 1c 1d 1e 1f 20 21 22 23 24 WORD_RAMP 8 0015 0016 0017 0018 0019 001a 001b 001c QUAD_RAMP 9 00000015 00000016 00000017 00000018 BYTE_LFSR 10 1c 38 71 e3 c6 8d 1a 34 68 d0 a0 41 82 04 09 12 RANDOM 11 14 5b 52 66 77 c5 bc 76 5a 6e d3 e2 ...

Page 245: ...ibuted fabric wide to its local time Refer to tsTimeZone for more information on time zone support If the switch is operating in FICON Management Server mode fmsMode setting the date is subject to the director clock alert mode DCAM If DCAM is 1 the operator issues a warning that the switch date is about to change The operator then prompts to confirm the change with a yes or no response NOTES This ...

Page 246: ...EXAMPLES To display the current date and time and then modify it switch admin date Thu Mar 24 17 15 00 UTC 2011 switch admin date 03224182011 Thu Mar 24 18 20 26 UTC 2011 SEE ALSO errShow ficonCupSet ficonCupShow portLogShow tsClockServer tsTimeZone upTime ...

Page 247: ... and verbosity levels NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operand module_name Specifies the name of the module for which you want to view the debug and verbosity levels Module names are cas...

Page 248: ...t_Cfg as the effective zone configuration OPERANDS This command has the following operands noaccess Sets the default zone access mode to No Access initializes a zoning transaction if one is not already in progress and creates the reserved zoning objects equivalent to the following zoning commands cfgCreate d_efault_Cfg d_efault_Zone zoneCreate d_efault_Zone 00 00 00 00 00 00 00 01 A cfgSave cfgEna...

Page 249: ...e defzone allaccess cfgsave An audit log record is generated for each use of this command show Displays the current state of the default zone access mode EXAMPLES To create a default zone configuration primaryfcs admin cfgactvshow Effective configuration No Effective configuration primaryfcs admin defzone noaccess primaryfcs admin cfgsave primaryfcs admin defzone show Default Zone Access Mode comm...

Page 250: ...al Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operand slot slot Specify the slot on which to clear the diagnostics failure status The default is set to 0 and designed to operate on fixed port count products all If specified all blades clear EXAMPLES To c...

Page 251: ...iagPost command to display the current POST status and use diagEnablePost to enable POST NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To disable the POST switch admin diagdisablepost Config update Succeeded Diagnost...

Page 252: ...d POST Phase II tests system functionality Use the diagPost command to display the current POST status and use diagDisablePost to disable POST NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To enable POST switch admin...

Page 253: ...e diagHelp command displays diagnostic commands that may not be available Execute help command to verify availability The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To display diagnostic command information switch admin dia...

Page 254: ...n Use diagEnablePost or diagDisablePost to modify the POST configuration NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To display the current POST configuration switch admin diagpost Diagnostic POST is currently disa...

Page 255: ... that are run NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following optional operands mode Specify 1 to enable retry mode Specify 0 to disable the feature show Displays the current mode setting The show opti...

Page 256: ...used The default slot is designed to operate on fixed port count products By default this command displays information for all user ports in the system uports itemlist Specify a list of user ports bports itemlist Specify a list of blade ports use_bports value If this value is nonzero this command displays the diagnostics status for the blade ports specified in use_bports otherwise the command disp...

Page 257: ...ssword database received from a switch running pre v6 3 0 firmware will be rejected by a Virtual Fabric enabled v6 3 0 chassis if it has more than one logical switch The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the fol...

Page 258: ...FCS PWD d Wildcard domains are 1 3 5 To distribute the FCS policy and the Password database to all domains in the fabric that support the distribute feature switch admin distribute p FCS PWD d To distribute the AUTH and FCS policies to all switches in the fabric that run Fabric OS v5 3 0 or later switch admin distribute p AUTH FCS d To distribute the AUTH and SCC policies to domains 1 and 3 in the...

Page 259: ...ng policy is in place DLS is always enabled It cannot be disabled and the dlsReset command fails The command generates a message stating that DLS cannot be changed with current routing policy If Lossless is enabled the feature remains enabled until you disable it with the dlsSet disable lossless command If DLS is already disabled the command output confirms the disabled status DLS is not set uncha...

Page 260: ...ssless option Dynamic load sharing without frame loss is supported in logical fabrics and is configured per logical switch However there is a potential impact on other logical switches because they share the same hardware Chassis permissions are required to configure DLS in a logical fabric environment For example assume a chassis is partitioned as follows logical switch LS1 consists of ports 1 0 ...

Page 261: ...egacy dlsSet command Dynamic load balancing is enforced but not without frame loss DLS legacy mode continues to be enabled after Lossless is disabled Use dlsReset to disable DLS completely help Displays the command usage EXAMPLES DLS configuration commands on a switch with an exchange based policy switch admin aptpolicy Current Policy 3 0 ap 3 0 ap Default Policy 1 Port Based Routing Policy 3 Exch...

Page 262: ...ess are set switch admin dlsshow DLS is set with Lossless enabled switch admin dlsset Lossless is set unchanged switch admin dlsset disable lossless Lossless is not set switch admin dlsshow DLS is not set To attempt to enable Lossless while XISL use is enabled switch admin dlsset enable lossless Lossless option cannot be enabled when XISL use is allowed Please disable the switch with switchdisable...

Page 263: ...ss enabled DLS is enabled with the Lossless feature Load sharing is recomputed with every change in the fabric and existing routes can be moved to maintain optimal balance In Lossless mode no framers are lost during this operation DLS is set by default with current routing policy DLS is set with Lossless enabled Indicates that the current routing policy Exchange based requires DLS to be enabled by...

Page 264: ...place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To set the DNS parameters for the system switch admin dnsconfig Enter option 1 Display Domain Name Service DNS configuration 2 Set DNS configuration 3 Remove DNS configuration 4 Quit Select an item 1 4 4 2 Enter Domain Name domain com Enter Name Server IP address in dot notation...

Page 265: ...ttribute Valid attributes include the following id The vendor specific enclosure identifier modelname The vendor specific enclosure model name slotid The identifier of the enclosure interface to which the switch is attached rackname The name assigned by the enclosure manager to the rack rackid The serial number assigned by the enclosure manager to the rack enclosurename The name assigned by the en...

Page 266: ...64 01 enclosureShow 22 connfuse Information about whether or not the switch has a fuse EXAMPLES To display the identifier of the enclosure interface to which the switch is attached switch admin enclosureShow slotid Bay 4 SEE ALSO chassisShow ...

Page 267: ...are cleared For products that contain multiple processors this command can be executed on either control processor It clears the error log only on the CP where the command is executed For example to clear the error log on the standby CP issue errclear on the standby CP NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapte...

Page 268: ...limiters are displayed only at the console they are not displayed in a Telnet session or in the RASLog OPERANDS This command has the following operands s start_delimiter_string Specifies an alphanumeric string for the start delimiter The string can be up to 10 characters long and must be enclosed in double quotation marks This operand is optional e end_delimiter_string Specifies the alphanumeric s...

Page 269: ...he start of a message Timestamp Timestamp for the message Message ID Message identifier External sequence number Sequence number for the message Security audit flag Security audit message displayed as AUDIT Severity Severity of the message Valid values include INFO WARNING ERROR and CRITICAL Switch name Switch name for the generator of this message or chassis Message Message body End delimiter Del...

Page 270: ...ation Login successful via TELNET SSH RSH IP Addr 10 106 7 62 2010 12 17 22 29 17 ZONE 1022 9037 CHASSIS INFO Spir_67 The effective configuration has changed to meh 2010 12 17 22 29 17 FABR 1001 9041 CHASSIS WARNING Spir_67 port 0 incompatible Long distance mode 2010 12 17 22 29 17 LOG 1000 9043 CHASSIS INFO Spir_67 Previous message repeated 1 time s output truncated SEE ALSO errDelimiterSet errFi...

Page 271: ...ictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands d destination Specifies the destination for the filter The string console is the only valid value at this time v severity Specifies the minimum severity level of the message to pass through the filter Valid values are INFO WARNING...

Page 272: ...Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To display a list of all defined error log modules switch user errmoduleshow Module IDs 1 KT 2 UT 3 TRCE 4 KTRC 5 LOG 6 CDR 7 BLPU 8 PISP 9 PIXE 10 EGR 11 BL 12 PIC 13 PS 14 RTE 15 AS 16 AUTH 17 BLDE 18 BLM 19 BPRT 20 CE...

Page 273: ...ssage Timestamp Timestamp for the message Message ID Message identifier External sequence number Sequence number for the message Security audit flag Security audit message displayed as AUDIT Severity Severity of the message Valid values include INFO WARNING ERROR and CRITICAL Switch name Switch name for the generator of this message or chassis Message Message body End delimiter Delimiter string fo...

Page 274: ...7 62 Type CR to continue Q CR to stop 2010 08 25 10 13 41 ZONE 1022 9037 CHASSIS INFO Spir_67 The effective configuration has changed to meh Type CR to continue Q CR to stop 2010 08 25 11 35 04 FABR 1001 9041 CHASSIS WARNING Spir_67 port 0 incompatible Long distance mode Type CR to continue Q CR to stop 2010 08 25 11 39 35 LOG 1000 9043 CHASSIS INFO Spir_67 Previous message repeated 1 time s Type ...

Page 275: ...Fabric OS Command Reference 241 53 1001764 01 exit 22 exit DESCRIPTION See logout SEE ALSO None ...

Page 276: ...Exchange Fabric Parameters HA_EFP Exchange Fabric Parameters used during warm recovery DIA Domain Identifier Assigned RDI Request Domain Identifier BF Build Fabric FWD Fabric Controller Forward EMT Fabric Controller Mark Timestamp ETP Fabric Controller Trunk Parameters RAID Return Address Identifier GAID Get Address Identifier ELP_TMR Used internally for fabric application not a SW_ISL GRE Get Rou...

Page 277: ...efer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To display the retry count of Fabric OS Commands switch user fabretryshow SW_ILS E_Port ELP EFP HA_EFP DIA RDI BF FWD EMT ETP RAID 34 0 0 0 0 0 0 0 0 0 0 35 0 0 0 0 0 0 0 0 0 0 GAID ELP_TMR GRE ECP ESC EFMD ESA DIAG_CMD 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 SEE ALSO None ...

Page 278: ...g format HH MM SS MS Input and Action Fabric log message An asterisk in the message indicates an action S Current switch state Valid switch states include the following FO Build Fabric BF received F1 Reconfigure Fabric RCF is not supported F2 Exchange Fabric Parameters EFP is waiting for last Accept Frame ACC from flood F3 Flood EFPs D0 The switch is the principal switch D1 The principal switch is...

Page 279: ...ed I2 Trunk Initiator ETP sent I3 Trunk Initiator Link reset occurred I4 Trunk Initiator Link reset done on slave T0 Trunk Target EMT received T1 Trunk Target ETP received T2 Trunk Target Link reset T3 Trunk Target Link reset done on slave LD Dynamic long distance ECP sent or received ESC Exchange Switch Capabilities ESC state between P2 and P3 Sn Next switch state Refer to switch states for valid...

Page 280: ...og s Time Stamp Input and Action S P Sn Pn Port Xid Switch 0 Fri Feb 11 15 30 46 2011 GMT GMT 0 00 15 30 46 477642 Fss Init NA NA NA NA NA NA 15 30 46 482452 Initiate State NA NA F2 NA NA NA 15 30 46 522451 Expd1 0x00000000 00000000 000001ff f77ffcef F2 NA F2 NA 0 NA 15 31 08 739983 Rcv sync dump vers 7 F2 NA F2 NA NA NA 15 31 08 744777 Cold Init F2 NA F2 NA NA NA 15 31 08 745209 Removing all node...

Page 281: ...endix A Command Availability for details Fabric name support requires Fabric OS v7 0 0 firmware and will be lost on downgrade OPERANDS This command has the following operands set fabric_name Sets the fabric name The fabric name is a unique character string and can be up to 128 characters long You can use any character including spaces and meta characters A fabric name that includes spaces must be ...

Page 282: ...01764 01 fabricName 22 switch user fabricname show Fabric Name my new fabric To clear the fabric name switch user fabricname clear Fabric Name cleared switch user fabricname show Fabric Name is not configured SEE ALSO switchShow fabricShow ...

Page 283: ...itches should be interconnected first followed by additional switches to enlarge the fabric NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands help h Displays the command usage show Displays the ...

Page 284: ...ty to the default value 0xFE f mode Sets the principal switch mode Specify 1 to enable principal switch mode Specify 0 to disable principal switch mode Optionally use the f operand to force a fabric rebuild Mode changes take effect when the fabric rebuilds This operand is optional EXAMPLES To enable a high fabric principal priority setting switch admin fabricprincipal enable p 0xff f Principal Sel...

Page 285: ...ference 251 53 1001764 01 fabricPrincipal 22 To display the principal switch selection priority switch admin fabricprincipal show Principal Selection Mode Enable Principal Switch Selection Priority 0x10 SEE ALSO fabricShow ...

Page 286: ...e The switch WWN Enet IP Addr The switch Ethernet IP address for IPv4 and IPv6 configured switches For IPv6 switches only the static IP address displays FC IP Addr The switch FC IP address Name The switch symbolic name An arrow indicates the principal switch FC Router IP Addr The IP address of the FC Router This field is empty if the switch is not an FC Router or it the FC Router does not support ...

Page 287: ...ame Enet IP Addr FC IP Addr Name 64 fffc40 10 00 00 60 69 00 06 56 192 168 64 59 192 168 65 59 sw5 65 fffc41 10 00 00 60 69 00 02 0b 192 168 64 180 192 168 65 180 sw180 66 fffc42 10 00 00 60 69 00 05 91 192 168 64 60 192 168 65 60 sw60 67 fffc43 10 00 00 60 69 10 60 1f 192 168 64 187 0 0 0 0 sw187 The Fabric has 4 switches Fabric Name mainFabricA To show a mixed fabric with IPv4 and IPv6 configure...

Page 288: ... the chassis switch admin fabricshow chassis Switch ID Name ENET IP Addr Chassis WWN Chassis Name 4 fffc04 sw5100_126_128 10 38 17 126 10 00 00 05 1e 0e eb 58 Brcd5100 5 fffc05 sw1500_127_128 10 38 17 127 10 00 00 05 1e 0e eb 98 Brcd5100 The Fabric has 2 switches SEE ALSO fabricName switchShow ...

Page 289: ...ated Admin Domain header conflict Virtual Fabric Admin Domain conflict MSFR RD H T WWN conflict internal only Enhanced Overlapping TI zones ETIZ Incompatibility Exchange Switch Capabilities ESC detected conflict Encryption conflict Both ends are not configured for encryption Compression conflict Both ends are not configured for encryption Encryp Comp bw availability Encryption or compression Confi...

Page 290: ...ID forcibly changed 0 E_Port offline transitions 0 Reconfigurations 2 0 Sat Dec 18 14 29 56 2010 Segmentations due to Loopback 0 Incompatibility 0 Overlap 0 Zoning 0 E_Port Segment 0 Licensing 0 Disabled E_Port 0 Platform DB 0 Sec Incompatibility 0 Sec Violation 0 ECP Error 0 Duplicate WWN 0 Eport Isolated 0 AD header conflict 0 VF AD conflict 0 MSFR RD H T WWN conflict 0 ETIZ Incompatibility 0 ES...

Page 291: ...ded systems except for the Brocade 5300 The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operand unit Specifies the number of the fan unit to disable EXAMPLES To disable a fan unit switch admin fandisable 1 F...

Page 292: ... nonbladed systems except for the Brocade 5300 The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operand unit Specify the fan unit number to enable EXAMPLES To enable a fan unit switch admin fanenable 1 Fan un...

Page 293: ...ed faulty Fan has exceeded hardware tolerance and has stopped In this case the last known fan speed is displayed The output from this command varies depending on switch type and number of fans present NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for ...

Page 294: ...port and can be later assigned to a physical device A FA PWWN can be either user generated or automatically assigned by the fabric The automatically assigned FA PWWN is created by default when you enable the feature without explicitly providing a VPWWN With FA PWWNs assigned to FC ports or Access Gateway AG ports you can provision the ports in advance with zoning configurations access control or P...

Page 295: ... device is logged into the Access Gateway Virtual Port WWN The FA PWWN user assigned or automatically assigned created on the FC switch for the Access Gateway port The following information is displayed for both AG and FC switch ports PID Port ID Enable Displays yes if the configuration is enabled displays No if the configuration is disabled MapType Displays the type of mapping Access Gateway AG o...

Page 296: ... a FA PWWN to an AG port you must specify the AG node WWN to uniquely identify the AG The new FA PWWN will take effect upon the next login session delete Deletes the active FA PWWN from the specified ports If a port is bound to a user assigned FA PWWN this command deletes the currently active FA PWWN and activates the automatically assigned FA PWNN If the active FA PWWN is automatically assigned a...

Page 297: ...ce AG by its node WWN This operand is required only when moving ports between Access Gateways dstag AG_WWN Specifies the destination AG by its node WWN This operand is required only when moving ports between Access Gateways srcport source_port Specifies the port from which to move the PWWN dstport dest_port Specifies the destination port for the moved PWWN help Displays the command usage EXAMPLES ...

Page 298: ...WN VPWWN PID Enable MapType 0 52 00 10 00 00 0f 50 30 10101 Yes Port Auto 1 11 22 33 44 33 22 11 22 Yes Port User 52 00 10 00 00 0f 50 44 10 52 00 10 00 00 0f 50 45 Yes Port Auto To display the active FA PWWN of an AG port fapwwn show ag 10 00 00 05 1e d7 3d dc port 8 AG Port Port Device Port WWN 10 00 00 05 1e d7 3d dc 8 20 20 08 00 05 1e d7 2b 74 Virtual Port WWN PID Enable MapType 11 22 33 44 5...

Page 299: ...n the following example one VPWWN is not unassigned fapwwn show ag 10 00 00 05 1e d7 3d dc AG Port Port Device Port WWN 10 00 00 05 1e d7 3d dc 16 10 00 00 05 1e d7 3d dc 9 20 20 09 00 05 1e d7 2b 73 10 00 00 05 1e d7 3d dc 8 20 20 08 00 05 1e d7 2b 74 10 00 00 05 1e d7 3d dc 16 Virtual Port WWN PID Enable MapType 52 00 10 00 00 0f 50 38 Yes AG Auto 20 00 10 00 00 0f 50 33 11404 Yes AG Auto 11 22 ...

Page 300: ...witch When the Standby CP comes up again it is temporarily no longer in sync with the Active CP When the Active CP reboots it fails over to the Standby CP The Standby CP becomes the new Active CP and traffic is disrupted When HA is disabled and fastBoot is issued on the Active CP both the Active and Standby CPs reboot with the original mastership retained The original Active CP remains the Active ...

Page 301: ...0 Sun Feb 28 19 49 45 2010 The system is going down for reboot NOW To reboot a DCX without executing POST on startup in the example HA is disabled switch admin fastboot This command is being run on a control processor CP based system Because HA is disabled it will cause both active CP and the standby CP to reboot After reboot the HA will be enabled Do you want to continue y n y Broadcast message f...

Page 302: ...vailability for details OPERANDS This command has the following operands slot slot Specifies the slot number on which the diagnostic operates The default is 0 testtype type Specifies the test type to run By default the command runs all tests Valid tests include the following 0 All tests 1 Network processor SRAM test 2 FCIP FPGA internal register test 3 FCIP FPGA interrupt test 4 FCIP FPGA checksum...

Page 303: ...TEST_TIMEOUT_ERR CHIP_TEST_HEARBEAT_ERR CHIP_TEST_INVALID_RESULT EXAMPLES To run all tests on slot 7 and GbE port 1 switch admin fcipchiptest slot 7 unit 1 testtype 0 Running fcipchiptest Test Complete fcipchiptest Pass 1 of 1 Duration 0 hr 1 min 15 sec 0 1 15 351 passed SEE ALSO fcipPathTest ...

Page 304: ...ic or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To display FCIP command help information switch admin fciphelp fastwritecfg Configure FC fastwrite feature deprecated portcfg Create Delete a new ip interface route arp entry or fcip tunnel on the GigE port portcmd Execute commands ...

Page 305: ...ished You must disable the switch before running this command NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands slot Tests all GbE ports in the specified slot This operand is optional if omitted...

Page 306: ...Brocade 7800 FX8 24 use the lb_mode option Both options are mutually exclusive When issued on the Brocade 7800 or FX8 24 this command causes the switch or blade to reboot NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command ...

Page 307: ...progresses until the specified number of frames is transmitted on each port The default value is 100 Brocade FR4 18i and Brocade 7800 FX8 24 length data_length Specifies the data length of the frames used in the test Brocade FR4 18i only The default is 1 024 the maximum is 2 112 FC frames and 8 196 data packets compress mode Specifies the compression device for which to select or to bypass data co...

Page 308: ...est 22 EXAMPLES To run the test on slot 2 with PHY loopback sending 10 frames switch admin fcippathtest slot 2 path 2 nframes 10 Running fcippathtest Test Complete fcippathtest Pass 10 of 10 Duration 0 hr 1 min 50 sec 0 1 50 942 passed SEE ALSO fcipChipTest ...

Page 309: ...ports configuration of these ports through the regular FC CLI is disabled Only the FCoE CLI commands can be used NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands slot Specifies the slot number ...

Page 310: ...he maximum value is 90 A value of 0 cancels the previous advertisement interval value A value of 1 to 90 is valid for changing the interval fipcfgshow Displays FIP configurations resetlogin Clears the logins that occurred through a front end port or from a device specified by the Enode s VN_Port WWN teport slot port Specifies the slot or port number device wwn Specifies the device WWN EXAMPLES To ...

Page 311: ...10G Online FCoE VF Port 0 VN Port s output truncated To display information about devices logged in to a specific FCoE port on the Brocade 8000 switch admin fcoe loginshow 31 Number of connected devices 1 Peer Type Connect Info Device WWN Device MAC FCOE_DEVICE Direct 10 00 00 00 c9 76 ec 18 00 00 c9 76 ec 18 Session MAC FCoE Port MAC Te port 0e fc 00 85 1f 01 00 05 1e 76 60 97 Te 0 23 To display ...

Page 312: ...ertisement Interval 0 VLAN fcmap 5 0xefc00 Default fcmap To display devices logged in to FCoE port 2 0 on the Brocade FCoE10 24 switch admin fcoe loginshow 2 0 Number of connected devices 1 Peer Type Connect Info Device WWN Device MAC FCOE_DEVICE Direct 10 00 00 05 1e 8f fb 12 00 05 1e 8f fb 12 Session MAC FCoE Port MAC Te port 0e fc 00 91 40 01 00 05 1e 7b 34 e0 Te 2 0 To display the configuratio...

Page 313: ... may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details The FCoE Login management feature is not supported in Access Gateway mode OPERANDS This command has the following operands help Displays the command usage show Displays the state of the FCoE login configuration including current transactions and effective saved configuration switch swwn Dis...

Page 314: ...VN_Ports to log in Use the fcoeLoginGroup command to configure allowed Enode VN_Ports disable Disables the FCoE login configuration management on the switch This allows unrestricted login on Enode V_Ports EXAMPLES To configure a login group and save the configuration switch admin fcoelogingroup create login_def_allowall self allowall switch admin fcoelogincfg save To display the saved configuratio...

Page 315: ...ation switch admin fcoelogincfg purge conflicting nonexisting switch admin To disable the FCoE login configuration management on the switch switch admin fcoelogincfg disable switch admin fcoelogincfg show Login management is disabled Effective Configuration Login management is disabled SEE ALSO fcoeLoginGroup ...

Page 316: ...command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands help Displays the command usage create Creates a login group with the specified name and associates it with a specified switch lgname Specifies the name of the login group ...

Page 317: ...h VN_Port devices are to be removed wwn Identifies the WWN of the VN_Port The WWN must be specified in hex format as xx xx xx xx xx xx xx x Only specified members are allowed to log in to the switch rename Renames the specified login group The following operands are required lgname Specifies the current name of the login group newlgname Specifies the new name for the login group EXAMPLES To create...

Page 318: ...used to determine if the identifiers are zoned together When you use fcPing to probe a single destination an ELS Echo is sent to the specified destination and a response obtained The destination can be a switch WWN a domain ID or a switch domain controller ID No zoning check is performed when a single device is probed When you use fcPing with the allpaths option the command exercises a SuperPing A...

Page 319: ...le device specify the destination as a PID a switch WWN a domain ID or a switch domain controller ID When using fcPing with the allpaths option specify the destination as a PID a switch WWN or a domain ID source Specifies the source port ID port WWN or node WWN This operand is optional it is not valid with the SuperPing command allpaths The following operands are valid only when fcPing is executed...

Page 320: ...ied SuperPing checks the ISL coverage and keeps resending framers until the minimum coverage condition to is met or until the maximum number of echo frames specified in maxtries has been sent For example assuming a coverage count of 100 and a Maxtries value of 300 SuperPing will send 100 frames at a time and checks if each ISL is covered at least 100 times If not SuperPing will keep sending 100 fr...

Page 321: ...d out Request timed out 5 frames sent 0 frames received 0 frames rejected 5 frames timeout Round trip min avg max 0 0 0 usec To use fcPing with a single destination in the example the destination is a switch WWN switch admin fabricshow Switch ID Worldwide Name Enet IP Addr FC IP Addr Name 6 fffc06 10 00 00 05 1e 34 2b 66 10 202 90 201 0 0 0 0 mps_daz_1 55 fffc37 10 00 00 05 1e 34 01 f5 10 202 90 2...

Page 322: ... c9 3f 7c b8 12 bytes time 714 usec received reply from 20 00 00 00 c9 3f 7c b8 12 bytes time 741 usec received reply from 20 00 00 00 c9 3f 7c b8 12 bytes time 880 usec 5 frames sent 5 frames received 0 frames rejected 0 frames timeout Round trip min avg max 713 774 880 usec To execute a SuperPing testing all ISLs to a specified destination in the example two paths are tested and each hop is disp...

Page 323: ...ize 12 bytes destination domain 101 through all paths PATH SWITCH1 SWITCH2 1 3 EMB 3 123 128 165 96 165 99 128 2 3 EMB 3 205 128 2 25 2 1 128 3 3 EMB 3 205 128 2 25 2 42 128 4 3 EMB 3 204 128 2 27 2 42 128 5 3 EMB 3 204 128 2 27 2 1 128 SWITCH3 STATUS 101 16 101 EMB 128 SUCCESS 101 8 101 EMB 128 FAILED 101 3 101 EMB 128 FAILED 4 101 3 101 EMB 128 FAILED 101 8 101 EMB 128 FAILED Completed superping...

Page 324: ...nation domain 165 through all paths PATH SWITCH1 SWITCH2 SWITCH3 1 3 EMB 3 205 128 207 25 207 42 128 101 3 101 16 128 2 3 EMB 3 204 128 207 27 207 42 128 101 3 101 16 128 SWITCH4 STATUS 165 99 165 0 128 SUCCESS 165 99 165 0 128 SUCCESS Successfully completed superping for all paths ISL COVERAGE SNO ISL STATUS 1 3 205 207 25 SUCCESS 4025 4025 2 3 204 207 27 SUCCESS 5 5 3 207 42 101 3 SUCCESS 4030 4...

Page 325: ...n logged by the Fibre Channel Protocol daemon FCPD NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To clear the FCPD debug information log switch admin fcplogclear SEE ALSO fcpLogDisable fcpLogEnable fcpLogShow ...

Page 326: ...ug information by the Fibre Channel Protocol daemon FCPD NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To disable the FCPD debug information log switch admin fcplogdisable SEE ALSO fcpLogClear fcpLogEnable fcpLogShow...

Page 327: ...n FCPD logging Debug information logging is enabled by default NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To enable the FCPD debug information log switch admin fcplogenable SEE ALSO fcpLogClear fcpLogDisable fcpLo...

Page 328: ...S To display the FCPD debug information log switch admin fcplogshow Switch 0 Sat Dec 18 14 22 05 2010 14 22 05 799269 Flush or Probe rcvd port 15 Line 16777862 scn_type 2 14 22 05 799279 Probe flush port 15 Line 16780554 flag 0 14 22 17 469561 Flush or Probe rcvd port 15 Line 16777862 scn_type 1 14 22 17 469567 Probe Msg Rcvd port 15 Line 16777899 prev_state 0 msg_scn_arg1 0 14 22 17 470618 fcpSta...

Page 329: ...endix A Command Availability for details OPERANDS This command has the following operands slot For bladed systems only specify the slot number of the port to display followed by a slash port Specify the port number to display relative to its slot for bladed systems Use switchShow to list valid ports This operand is required EXAMPLES To display the FCP probe information switch admin fcpprobeshow 31...

Page 330: ...ng Device probing and RLS probing are disabled by default Use the configure command to enable these parameters NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands slot For bladed systems only spec...

Page 331: ...Shows the current broadcast configuration as enabled or disabled If broadcast frame forwarding is disabled for selected FIDs only the enabled FIDs in the current configuration are displayed enable Enables the frame forwarding option for a specified fabric ID disable Disables the frame forwarding option for a specified fabric ID f fabric_id Specifies the fabric ID to be disabled or enabled Valid va...

Page 332: ...abric OS Command Reference 53 1001764 01 fcrBcastConfig 22 To display the new configuration switch admin fcrbcastconfig show Broadcast configuration is enabled for FID 2 128 SEE ALSO bcastShow portRouteShow ...

Page 333: ...ster is effectively tested with the following patterns 0x0001 0x0002 0x0004 0x0008 0x0010 0x0020 0x0040 0x0080 0x0100 0x0200 0x0400 0x0800 0x1000 0x2000 0x4000 0x8000 Repeat the steps until all FPGA registers are tested The built in self test BIST runs to verify the static random access memory SRAM of the FPGAs NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restri...

Page 334: ...ore of the following DMA_ALLOC_FAIL DMA_READ_ABORT DMA_READ_TIMEOUT CHIP_INIT_TIMEOUT BIST_TIMEOUT BIST_FAIL EXAMPLES To run all tests on slot 7 and FC Router FPGA 1 switch admin fcrchiptest slot 7 unit 1 testtype 0 Running fcrchiptest Test Complete fcrchiptest Pass 1 of 1 Duration 0 hr 0 min 4 sec 0 0 4 351 passed SEE ALSO fcrPathTest portLoopbackTest ...

Page 335: ...ix A Command Availability for details OPERANDS This command interactively prompts for the following parameter Backbone Fabric ID A fabric ID uniquely identifies a fabric in FC Router configurations The backbone fabric is the fabric attached to the U_Ports of the switch for example E_Ports or F_Ports The backbone fabric ID must be unique across all fabrics connected to the FC Router Use the switchS...

Page 336: ...s on the EX_Port configuration If the EX_Port is online the command displays the FID the EX_Port to which it is assigned the E_Port the port WWN and the switch WWN If the EX_Port is offline the command displays the FID the EX_Port to which it is assigned and an OFFLINE message IF no EX_Ports are configured in the switch the command displays No EX port Configured If no EX_Ports are configured withi...

Page 337: ...dmin fcredgeshow fid 25 FID EX port E port Neighbor Switch PWWN SWWN 25 11 244 20 f4 00 05 1e 38 a4 cb 10 00 00 05 1e 38 a4 cb To display a FID for which no EX_Ports are configured switch admin fcredgeshow fid 29 No EX ports with FID 29 SEE ALSO fcrPhyDevShow fcrProxyDevShow fcrRouteShow lsanZoneShow switchShow fcrFabricShow ...

Page 338: ...ured only the static IP address displays for each FC Router found on the backbone fabric EX_Ports A listing of active EX_Ports for the FC Router and information about these EX_Ports This information includes EX_Port The port number for the EX_Port An asterisk at the end of the line indicates that the EX_Port is a Remote Router Port FID The fabric ID of the EX_Port Neighbor Switch Info WWN enet IP ...

Page 339: ... 80 10 00 00 05 1e 38 01 e7 B10_3 10 2 10 33 35 80 10 00 00 05 1e 38 01 e7 B10_3 FC Router WWN 10 00 00 05 1e 39 51 67 Dom ID 5 Info 10 33 36 96 Scimitar EX_Port FID Neighbor Switch Info enet IP WWN name 151 2 10 33 35 80 10 00 00 05 1e 38 01 e7 B10_3 SEE ALSO fcrPhyDevShow fcrProxyDevShow fcrRouteShow lsanZoneShow switchShow ...

Page 340: ...mported permanently when host and target are zoned together even if the host is not present This mechanism facilitates a speedy discovery process by reducing instances of failure related to timeouts Once the devices that belong to the target edge fabric are defined as speed LSANS the import or export can occur with a minimum amount of delay when hosts reboot or are added to the zone database The f...

Page 341: ...AN tag database EXAMPLES To add an LSAN enforcement tag named brocade switch admin switchdisable switch admin fcrlsan add enforce brocade LSAN tag set successfully To add a speed tag named mcdt switch admin fcrlsan add speed mcdt LSAN tag set successfully To remove the LSAN enforcement tag brocade switch admin fcrlsan remove enforce brocade LSAN tag removed successfully To remove the speed tag mcd...

Page 342: ...rent maximum LSAN counts may lead to different devices being imported on different FCRs Because the maximum number of LSANs is configured per switch if there is a different maximum LSAN count on the switches throughout the meta SAN the device import or export will not be identical on the FCRs You should therefore enter the same maximum LSAN count for all the FCR switches in the same backbone that ...

Page 343: ...at all edge fabrics have two way communication In the case where 1 and 2 are specified with the add option to have access to each other then 1 can access only 2 2 can access only 1 3 4 5 can access each other but cannot access 1 or 2 The FIDs entered are not required to be online when you set up the LSAN fabric matrix The LSAN fabric matrix information is automatically distributed to all switches ...

Page 344: ...se an error message is displayed cancel lsan fcr Cancels the data that was not applied reverts to the persistent information display lsan fcr all Displays the information saved in the cache fabricview lsan fcr Views all the static and default dynamic fabric binding in the backbone verify lsan fcr Verifies if the LSAN Zone information previously entered and stored in the cache can be successfully a...

Page 345: ...n page for the corrective action Corrective actions Check that all FCR switches in the backbone support the LSAN Binding feature otherwise the feature is not supported Execute fcrlsanmatrix fabricview to confirm that all the switches in the backbone have the same LSAN binding matrix If not clear the LSAN binding feature on all the switches and reapply the same LSAN binding matrix on all the FCR sw...

Page 346: ... Fabric 52 10 00 00 06 2b 0e 4d e5 01f001 78 4e0000 Imported 52 10 32 16 90 28 dd d0 03 0bf001 82 2a0900 Imported 52 10 32 16 91 24 dd d0 07 0bf002 82 520c00 Imported 52 10 32 16 91 25 dd d0 06 01f002 78 4e3000 Imported 78 10 00 00 06 2b 0d 29 31 09f002 52 482200 Imported 78 10 32 16 90 29 dd d0 07 08f002 82 2a0a00 Imported 78 10 32 16 91 24 dd d0 05 09f001 52 48a100 Imported 78 10 32 16 91 25 dd ...

Page 347: ...tic and the default dynamic fabric binding in the backbone switch admin fcrlsanmatrix fabricview lsan LSAN MATRIX is activated Fabric ID 1 Fabric ID 2 52 78 52 82 78 82 Default LSAN Matrix 57 91 SEE ALSO fcrFabricShow lsanZoneShow fcrPhyDevShow fcrProxyDevShow fcrRouteShow switchShow ...

Page 348: ...rror counters are nonzero ENC_in CRC_err TruncFrm FrmTooLong BadEOF Enc_out BadOrdSet DropRxUnavail 6 Check if the transmit receive or Class 3 receiver counters are stuck at some value 7 Check if the number of frames transmitted is not equal to the number of frames received 8 Repeat steps 2 through 7 for all ports present until one of the following conditions is met a The number of frames or passC...

Page 349: ...or more of the following DIAG DATA The payload received by the specified port did not match the transmitted payload A cable media or ASIC failure is the probable cause Check for a faulty SFP Replace the SFP if necessary DIAG ERRSTAT One of the ASIC internal counters detected a frame statistics error in the received frame A cable media or ASIC failure is the probable cause Check for a faulty SFP Re...

Page 350: ...faulty SFP Replace the SFP if necessary DIAG XMIT The specified port failed to transmit frames This usually indicates an ASIC failure Replace the blade or the switch EXAMPLES To test slot 2 with FC Router FPGA Serdes loopback sending 10frames switch admin fcrpathtest slot 2 path 2 nframes 10 Running fcrpathtest Test Complete fcrpathtest Pass 10 of 10 Duration 0 hr 0 min 18 sec 0 0 18 942 passed SE...

Page 351: ...evices based on fabric ID or port world wide name No device found is displayed if there is no physical device information available at the current FC Router Each line of the output displays Device Exists in Fabric The fabric in which the physical device exists WWN The world wide name of the device port Physical PID The port ID of the physical device This port ID is only relevant on the fabric spec...

Page 352: ...es the device login failed due to missing LSAN zones within the remote fabric EXAMPLES To display the physical devices relevant to an FC Router fcr admin fcrphydevshow Device WWN Physical Exists PID in Fabric 2 10 00 00 00 c9 2b 6a 68 c70000 3 50 05 07 65 05 84 09 0e 0100ef 3 50 05 07 65 05 84 0b 83 0100e8 Total devices displayed 3 SEE ALSO fcrFabricShow fcrProxyDevShow fcrRouteShow lsanZoneShow s...

Page 353: ...roxy device configuration attributes apply to the local FC Router Multiple FC Routers attached to the same edge fabric coordinate to present the same proxy devices As a result persistent proxy device configurations must be consistent across all FC Routers attached to the same edge fabric or unpredictable results may occur If the proxy device configuration is not altered no action is required If th...

Page 354: ...xy device WWNs from their slots using the r operand and try again All slots are used for the specified edge fabric The specified slot already contains a WWN overwrite y The specified slot already contains an entry You are then prompted for confirmation r importedFID devWWN Removes the specified devWWN format XX XX XX XX XX XX XX XX from its slot for the edge fabric specified by importedFID 1 throu...

Page 355: ...evices are listed by fabric Search parameters f and w allow searching for proxy devices based on fabric ID or port WWN No proxy device found is displayed if there is no proxy device information available on this FC Router This command displays the following information Proxy Created in Fabric The fabric in which the proxy device has been created WWN The WWN of the device port Proxy PID The port ID...

Page 356: ... to this FC Router w wwn Displays proxy devices with the specified port WWN EXAMPLES To display the proxy devices relevant to this FC Router switch admin fcrproxydevshow Proxy WWN Proxy Device Physical State Created PID exists PID in Fabric in Fabric 2 50 05 07 65 05 84 09 0e 01f001 3 0100ef Imported 2 50 05 07 65 05 84 0b 83 01f000 3 0100e8 Imported 3 10 00 00 00 c9 2b 6a 68 02f000 2 c70000 Impor...

Page 357: ...switch could still be accessible through other switches Across a switch reboot the allocation starts from the next usable WWN from the pool and not from the beginning Phantom Port WWNs The maximum versus the currently used phantom domain port WWNs Phantom domain ports require port WWNs for manageability purposes Phantom domain ports include ports connecting front and translate domains virtual ISLs...

Page 358: ...LSAN Zones 3000 22 LSAN Devices 10000 1208 Proxy Device Slots 10000 2 WWN Pool Size Allocated Phantom Node WWN 8192 3790 Phantom Port WWN 32768 6446 Port Limits Max proxy devices 2000 Max NR_Ports 1000 Currently Used column 1 proxy column 2 NR_Ports 48 0 0 49 0 0 50 0 0 52 0 0 53 0 0 54 0 0 60 0 0 63 1 4 176 1 4 177 1 4 183 1 4 190 0 0 SEE ALSO fcrFabricShow fcrProxyDevShow fcrRouteShow lsanZoneSh...

Page 359: ...t only on a disabled port The bandwidth of an inter fabric link IFL is unrelated to its default cost In other words 1 Gbps 2 Gbps 4 Gbps and 8 Gbps EX_Port IFLs have the same cost value of 1000 as their FC Router port The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availa...

Page 360: ...ortcost 7 10 Port Cost 7 10 1000 To set the cost of an EX_Port and display the result switch admin fcrrouterportcost 7 10 10000 switch admin fcrrouterportcost 7 10 Port Cost 7 10 10000 To set the default cost on the EX_Port switch admin fcrrouterportcost 7 10 0 switch admin fcrrouterportcost 7 10 Port Cost 7 10 1000 SEE ALSO switchShow fcrRouteShow portCfgEXPort ...

Page 361: ...ic No routes found is displayed if there is no route information available at this FC Router There is no route information available if no EX_Ports are configured at this FC Router The output includes Destination Fabric ID The destination fabric NR_Port PID The port ID of the NR_Port The port ID is relevant only on the backbone fabric This NR_Port has a route to the destination fabric identified b...

Page 362: ...in ID from the principal switch in the EX_Port attached edge fabric The domain ID requested is the preferred domain ID You can set the preferred domain ID when the translate domain is not active and is persistently saved The principal switch attempts to provide the translate domain with the requested domain ID but it may not provide it if there are domain ID conflicts with other domains in the fab...

Page 363: ...ate phantom domain remove r Removes the preferred domain ID of the translate phantom domain The translate domain must be inactive to remove the preferred domain ID The following operands are required importedFID Specifies the fabric ID 1 through 128 of the fabric that contains the translate domain exportedFID Specifies the fabric ID 1 through 128 of the remote fabric represented by this translate ...

Page 364: ...d To set the preferred domain ID of the translate domain created in fabric 2 which represents the remote fabric 3 to a value of 8 switch admin fcrxlateconfig 2 3 8 xlate domain already configured overwrite n y To clear the preferred domain ID of the translate domain created in fabric 2 which represents remote fabric 3 switch admin fcrxlateconfig r 2 3 xlate domain deleted To enable translate domai...

Page 365: ...licy Automatic distribution of a fabric wide consistency policy is limited to SCC DCC and FCS policies Use the fabwideset parameter to enforce these policies fabric wide in tolerant or strict mode In strict mode fabric wide enforcement of FCS consistency policy is possible in mixed fabrics However switches that do not support the policies ignore them NOTES The execution of this command is subject ...

Page 366: ...nfiguration Server FCS All members specified in a given policy set are automatically distributed to all participating switches in the fabric that support the policy Refer to the DESCRIPTION section for specific exceptions In the presence of a fabric wide FCS consistency policy this command can only be run from the primary FCS switch EXAMPLES To display the fabric wide consistency policy and the ac...

Page 367: ...dentifiers and registered port lists are displayed No detailed HBA attributes are displayed For registered ports only port identifier and corresponding HBA are shown no detailed port attributes are displayed NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availabili...

Page 368: ...DS None EXAMPLES To display FDMI information on a local switch switch admin fdmishow Local HBA database contains 10 00 00 00 c9 25 9b 96 Ports 1 10 00 00 00 c9 25 9b 96 Port attributes FC4 Types 0x0001000001000000000000000000000000000000000000 000000000000000000 Supported Speed 0x00000001 Port Speed 0x00000001 Frame Size 0x00000800 HBA attributes Node Name 20 00 00 00 c9 25 9b 96 Manufacturer Emul...

Page 369: ...e port to be configured You can specify the port by its port index number or by a hexadecimal number Use switchShow for a listing of valid port index numbers set Sets the configuration entry reset Resets the configuration entry to its default value database Specifies the name of the FICON database The only database currently supported is the following LIRR Devices registered to receive link incide...

Page 370: ...is command has the following operand database Specifies the name of the FICON database The databases include the following RLIR Remove all entries from the link incidents database including implicit link incidents ILIR RNID Remove all the not current entries from the device node identification database The entries are for devices that were previously connected but are no longer online Note that cu...

Page 371: ...s FICON Management Server FMS mode cannot be enabled if port ID PID Format 2 is used Refer to the Fabric OS Administrator s Guide for information on PID formats The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the followin...

Page 372: ... state for this command to succeed Use ficonCupShow with the LP option to display the logical paths on the switch The following operands are required PID Specifies the Port identifier CHID Specifies the Channel ID CHID The CHID is the Logical Partition LPAR identifier supplied as part of the FICON protocol header The format of the CHID is a numerical identifier followed by a letter for example 1B ...

Page 373: ...Fabric OS Command Reference 339 53 1001764 01 ficonCupSet 22 082300 1C Oper 082400 1A Reset 082400 1B Reset 612400 1E Reset Prim 612400 1F Reset SEE ALSO ficonCupShow ...

Page 374: ...perand is specified all mode register bit settings are displayed If a mode register bit name is specified then only the value of that bit is displayed A value of 1 indicates that a given mode register bit is set and 0 indicates that it is not set The following operand is optional bitname Displays the specified mode register bit as either set 1 or not set 0 Valid values for bitname include the foll...

Page 375: ...isplay the ASM bit in the mode register for the switch switch user ficoncupshow modereg ASM ASM 1 To display the MIHPTO value for the CUP switch user ficoncupshow MIHPTO MIHPTO for the CUP 60 seconds To display the logical paths for the switch switch user ficoncupshow LP FICON CUP Logical Paths for CUP 0x08FE00 LP Reporting PID CHID State Path 082300 1A Oper Curr 082300 1B Oper 082300 1C Oper 0824...

Page 376: ...that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To display a list of FICON commands switch admin ficonhelp ficoncfg Manage FICON configuration ficonclear Clears contents of the specified FICON management database ficoncupset Sets FICON CUP parameters for a switch ficoncupshow Displays FICON CUP parameters for a...

Page 377: ...and Domain Displays the domain ID Fabric WWN Displays the fabric WWN Flag Indicates if the node is valid not valid or not current Flag values are as follows 0x00 Indicates the node ID of the storage port is valid 0x10 Indicates the node ID of the channel port is valid 0x20 Indicates the node ID of the storage port is not current 0x30 Indicates the node ID of the channel port is not current 0x40 In...

Page 378: ...d wide name Listener Type Indicates the listener type as follows Conditional This port receives a link incident record if no other recipients from the established registration list have been chosen Unconditional This port is always chosen as a recipient of a link incident record Manufacturer Displays the manufacturer name or code Model Number Displays the model number Node Parameters Same as Param...

Page 379: ...annel port 0x03 Input unit record if it is a storage port otherwise a reserved field for a channel port 0x04 Output unit if it is a storage port otherwise a reserved field for a channel port 0x05 Reserved field for a channel port 0x06 Controller if it is a storage port otherwise a reserved field for a channel port 0x07 Terminal Full screen if it is a storage port otherwise a reserved field for a c...

Page 380: ... not operational Port Type Displays the port type as one of the following U Unknown N N_Port NL NL_Port Protocol Displays whether the traffic is using FICON or FCP Registered Node WWN Displays the device s node world wide name associated with the device HBA Registered Port WWN Displays the device s channel or storage CU port world wide name associated with the device HBA Sequence Number Displays t...

Page 381: ...ive link incident reports Entries can have the following flags C A user configured LIRR entry defined as current set with the ficonCfg command C A LIRR entry defined by the management server demon as current based on order S A LIRR entry defined by the management server demon as secondary SwitchRNID Switch node identification RLIR Link incident reports ILIR Implicit link incident reports fabric Di...

Page 382: ...atabase switch admin ficonshow LIRR fabric Fmt Type PID Listener Port WWN 0x18 N 502d00 50 05 07 64 01 40 11 79 0x18 N 510d00 50 05 07 64 01 00 15 8c 0x18 N 510f00 50 05 07 64 01 00 14 62 Switch Port WWN Listener Type 20 2d 00 60 69 80 1e 4e Conditional C 20 0d 00 60 69 80 1e 4f Conditional S 20 0f 00 60 69 80 1e 4f Conditional The LIRR database has 3 entries Current LIRR device port number Not co...

Page 383: ...e 4e 10 00 00 60 69 80 1e 4e 0x00 0x200a2e Switch Part Number 060 0001501 05 Switch Serial Number 0FT02X801E4E Domain 20480 The local RLIR database has 1 entry To display the local ILIR database switch user ficonshow ILIR FRU Failure 2 Power Supply 2 failure occurred on Mon Jan 13 12 11 38 2003 Fmt Protocol Domain Fabric WWN Switch WWN 0x18 FICON 80 10 00 00 60 69 33 33 33 10 00 00 60 69 80 1e 4e ...

Page 384: ...350 Fabric OS Command Reference 53 1001764 01 ficonShow 22 N 0x502b00 50 05 07 64 01 00 15 8d The Local ILIR database has 2 entries SEE ALSO ficonClear ...

Page 385: ...procedure calls RPC root account boot prom access etc must be blocked before the system can enter FIPS mode LDAP should not be configured while FIPS is enabled The system must be rebooted for FIPS mode changes to take effect Refer to the Fabric OS Administrator s Guide for information on configuring your system for FIPS 140 2 level 2 compliance FIPS mode cannot be modified through configDownload F...

Page 386: ...oot permission EXAMPLES To display the current FIPS configuration switch admin fipscfg show FIPS mode is Disabled FIPS Selftests mode status is Disabled None To enable selftests switch admin fipscfg enable selftests You are enabling selftests Do you want to continue yes y no n no yes FIPS Selftests mode status has been set to Enabled None To verify FIPS prerequisites switch admin fipscfg verify fi...

Page 387: ...s time To back out of a zeroizing operation switch admin fipscfg zeroize You are Zeroizing FIPS configuration Do you want to continue yes y no n no no Operation cancelled switch admin fipscfg zeroize You are Zeroizing FIPS configuration Do you want to continue yes y no n no yes Executing secauthsecret remove all This command deletes database of DH CHAP secret keys If a fabric requires authenticati...

Page 388: ...n cancelled Zeroizing Radius configuration RADIUS configuration does not exist LDAP configuration does not exist Zeroizing IPSec static SA configuration Zeroizing SSH key Permission denied to perform this operation Failed to zeroize SSH public key switch admin To disable bootprom switch root fipscfg disable bootprom You are disabling bootprom Do you want to continue yes y no n no no Operation canc...

Page 389: ...dary partition with the new firmware to the primary The default behavior of the firmwareDownload command is to automatically run the firmwareCommit command after the reboot If you decide to disable the autocommit option when running firmwareDownload you must execute one of the following two commands after the CP is rebooted firmwareCommit copies the primary partition with new firmware to the secon...

Page 390: ... slot U c r pfile To download SAS firmware from a USB device and remove the existing SA firmware at the same time deprecated firmwaredownload a sas t slot slot U c r e pfile DESCRIPTION Use this command to download switch firmware from an FTP or SSH server or local NFS directory to nonvolatile storage Switch firmware can also be downloaded from an external USB device on platforms that support USB ...

Page 391: ... may vary depending on which Fabric OS version you are migrating from See the Fabric OS Administrator s Guide for restrictions on changing Fabric OS versions On certain occasions you may see messages in the console output of firmwareDownload These are internal messages generated by the Linux utilities You can safely ignore these messages For relevant Brocade generated firmware download messages re...

Page 392: ...d by the FTP server This operand is required when accessing an SSH server In Fabric OS v7 0 0 or later you can omit the password if the switch is configured as follows The switch must be configured with public key authentication Refer to the sshUtil help page for more information You select a secure protocol SCP or SFTP The private key is installed on the switch and the public key is exported to t...

Page 393: ...n on the host The password is not specified correctly Indicated firmware does not exist on the host or is not in the right format or is corrupted The FTP or SSH service is not running on the host The platform is not supported by the firmware indicated The USB device may not be plugged in correctly On standalone switches the device must be plugged into the switch USB port On enterprise class platfo...

Page 394: ...P 1 Password To download firmware without a password using public key authentication switch admin firmwaredownload Server Name or IP Address 10 38 17 17 User Name admin File Name users home25 admin dist Network Protocol 1 auto select 2 FTP 3 SCP 4 SFTP 1 3 Verifying if the public key authentication is available Please wait Success Do Auto Commit after Reboot Y y Reboot system after download N y Se...

Page 395: ...nloadstatus 1 Tue Mar 29 21 43 14 2011 Firmware is being downloaded to the switch This step may take up to 30 minutes 2 Tue Mar 29 21 48 26 2011 Firmware has been downloaded to the secondary partition of the switch 3 Tue Mar 29 22 06 57 2011 The firmware commit operation has started This may take up to 10 minutes 4 Tue Mar 29 22 10 19 2011 The commit operation has completed successfully 5 Tue Mar ...

Page 396: ...eration has started to restore the secondary partition 6 Fri Mar 25 16 58 45 2011 Slot 7 CP1 standby The firmware commit operation has started This may take up to 10 minutes 7 Fri Mar 25 17 05 34 2011 Slot 7 CP1 standby The commit operation has completed successfully SEE ALSO firmwareCommit firmwareDownload firmwareRestore firmwareShow ...

Page 397: ...Firmware Download is enabled and if the validation succeeds firmware download proceeds normally If the firmware is not signed or if the signature validation fails signed firmware download fails Refer to the Fabric OS Administrator s Guide for complete details on upgrading or downgrading firmware The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in ...

Page 398: ...e system and makes the former firmware active After the switch reboots both primary and secondary partitions restore the previous firmware This command only takes action if the system is booted after a firmwareDownload otherwise the process terminates with an error NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 ...

Page 399: ...at may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands history Displays the contents of the firmware download log For each firmware download record the command displays the date and time the switch name the slot number port ID and firmware version help Displays the command usage EXAMPLES To dis...

Page 400: ...oad history switch admin firmwareshow history Firmware version history Sno Date Time Switch Name Slot PID FOS Version 1 Fri Feb 18 12 58 06 2011 CDCX16 7 1556 Fabos Version v7 0 0d 2 Wed Feb 16 07 27 38 2011 CDCX16 7 1560 Fabos Version v7 0 0c SEE ALSO firmwareDownload firmwareDownloadStatus ...

Page 401: ... SCSI headers fall within the first 64 bytes of a frame frame monitors can detect different types of traffic transmitted through a port Each frame monitor keeps a timestamp of its last refresh It also keeps a generation count which is incremented each time the monitor is cleared Frame monitors generate alerts whenever the frame count for a certain frame type crosses the threshold configured for th...

Page 402: ...se the change option to modify one of the predefined frame types supported with this command You can modify the ports where the frames should be monitored or change the default threshold and alert mechanism You cannot change the bit pattern of a predefined frame type Predefined frame types include the following ABTS Specifies a frame of type ABTS Abort Sequence Basic Link Service command with a bi...

Page 403: ...as follows Offset Specifies the offset within the frame Offset 0 is the first byte of the start of frame SOF delimiter and offset 4 is the first byte of the frame header The offset must be in decimal format Valid values for offset are 0 and 4 to 63 Offset 0 is a special case that can be used to monitor the first four bytes SOFx frames The end of frame EOF delimiter cannot be monitored A maximum of...

Page 404: ...ne This operand is optional if omitted defaults are used snmp raslog Note that fmMonitor only supports specification of high thresholds and the actions taken when the frame count exceeds the configured high threshold Use the thConfig command with the filter class operand to configure and display other Fabric Watch thresholds and the actions to be taken when the counters fall below or in between co...

Page 405: ...optional if omitted this command lists all configured frame types on the switch along with their bit patterns The following operands are exclusive port port_list Specifies the ports for which to display the frame type configurations Refer to the description above for valid values all Displays information for all ports and frame types timeinterval interval Displayed the number of frames per second ...

Page 406: ...x08 0x28 0x0A 0x2A scsi2reserve 12 0xFF 0x08 4 0xFF 0x06 40 0xFF 0x16 0x56 scsi3reserve 12 0xFF 0x08 4 0xFF 0x06 40 0xFF 0x5F 41 0xFF 0x01 ip 12 0xFF 0x05 abts 4 0xFF 0x81 40 0xFF 0x81 12 0xFF 0x0 17 0xFF 0x0 baacc 4 0xff 0x84 12 0xff 0x00 17 0xff 00 To display configuration details for the predefine SCSI frame monitor Use thConfig filter class to set and display other Fabric Watch thresholds for ...

Page 407: ...0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 slot 1 630 0 0 0 0 0 0 0 0 0 630 0 0 0 0 0 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 slot 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 slot 1 210 840 210 0 0 0 0 0 0 0 0 0 0 0 0 0 2011 02 18 15 52 07 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 slot 1 630 0 0 0 0 0 0 0 0 0 630 0 0 0 0 0 16 17 18 19 20 21 22 23 24 25 26 27 28...

Page 408: ... Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands enable feature Enables a feature on the switch Valid values for feature include the following fcr Enables the FC Routing service on the switch The FC Routing service is disabled by default Use fosConfig show to determine if FCR is enabled or disabled When enabling FC...

Page 409: ... the command again FC Routing service is already disabled This means that the FC Routing service is already disabled iSCSI Not supported in Fabric OS v7 0 0 or later iSNSC Not supported in Fabric OS v7 0 0 or later vf Disables Virtual Fabrics on the switch This command prompts for confirmation because the chassis reboots after this command is executed ethsw Disables the Ethernet switch service Eth...

Page 410: ...tch admin fosconfig enable ethsw WARNING This operation will enable the Ethernet Switch Service on this switch Would you like to continue Y N y Enabling the Ethernet Switch Service Please wait Create Ethernet switch instance 0 All service instances in sync The Ethernet Switch Service has been enabled Please enable all of the Blades with ID 74 now To disable the Ethernet Switching service switch ad...

Page 411: ...rough fosexec fid all results in redundant output NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands fid FID Specifies the Fabric ID of the logical switch for which the command is executed fid al...

Page 412: ...ble 5 0 portenable on FID 128 portenable on FID 10 A port or ports is are not part of this switch portenable on FID 20 A port or ports is are not part of this switch To display the firmware version for all logical switches switch user fosexec fid all cmd firmwareshow v LF permission does not exist for one or more logical switches Would you like to continue Y N y firmwareshow on FID 10 Appl Primary...

Page 413: ...1001764 01 fosExec 22 To display the switch name for all logical switches without confirmation switch user fosexec fid all force cmd switchname switchname on FID 10 switch_10 switchname on FID 20 switch_20 SEE ALSO setContext userConfig ...

Page 414: ...odes summary and dump mode In summary mode the command aggregates similar frames those that have the same log timestamp TX port RX port SID DID SFID and DFID without displaying the raw frame contents In dump mode the command displays the raw frame contents but the frames are not aggregated in the manner of the summary mode In either mode you can specify additional filters to customize the number a...

Page 415: ...the frame log is timeout Frame contents The first 64 bytes of the frame contents in hexadecimal format NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details The Frame Log operation is chassis wide OPERANDS This command has the following operands d...

Page 416: ...ted in the lines of output than specified in the num_items value because one line can aggregate multiple frames in summary mode In dump mode each item represents a single frame The default value of num_items is 20 The maximum value in summary mode is 1200 and in dump mode it is 12 000 EXAMPLES To display eight lines of an unfiltered frame log view in summary mode switch user framelog show mode sum...

Page 417: ... 00 00 00 Jan 31 18 34 46 7 32 7 33 timeout 00 03 a0 00 00 03 a1 00 00 28 00 00 00 00 00 00 80 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Jan 31 18 34 46 7 32 7 33 timeout 00 03 a0 00 00 03 a1 00 00 28 00 00 00 00 00 00 80 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0...

Page 418: ...ES To replace the world wide name card switch admin frureplace wwn This is the WWN card hot swap interface Continuing from this point will require the whole process to be completed If this process is not complete due to a power cycle or CP failover please follow the recovery procedure in Core Switch WWN Card Replacement Procedure for appropriate chassis Do you wish to continue y n y Backing up WWN...

Page 419: ... confirmed isl_ports Bit map of all ISL ports Bit positions correspond to the default areas of the ports Bit 0 refers to default area of the switch bit 1 refers to default area 1 and so forth trunk_ports Bit map of all trunk slave ports f_ports Bit map of all FX_Ports seg_ports Bit map of all segmented ports active_ports Bit map of all online ports minLSArrival FSPF constant minLSInterval FSPF con...

Page 420: ...00000000 isl_ports 1 0x09020800 isl_ports 2 0x00000000 isl_ports 3 0x00000000 isl_ports 4 0x00000000 isl_ports 5 0x00000000 isl_ports 6 0x00000000 isl_ports 7 0x00000000 isl_ports 8 0x00000000 isl_ports 9 0x00000000 isl_ports 10 0x00000000 isl_ports 11 0x00000000 isl_ports 12 0x00000000 trunk_ports 0 0x00000000 trunk_ports 1 0xf60c0000 trunk_ports 2 0x00000000 trunk_ports 3 0x00000000 trunk_ports ...

Page 421: ..._ports 12 0x00000000 active_ports 0 0x05030403 active_ports 1 0xff0e0800 active_ports 2 0x00008307 active_ports 3 0x00000000 active_ports 4 0x00000000 active_ports 5 0x00000000 active_ports 6 0x00000000 active_ports 7 0x00000000 active_ports 8 0x00000000 active_ports 9 0x00000000 active_ports 10 0x00000000 active_ports 11 0x00000000 active_ports 12 0x00000000 minLSArrival 3000 minLSInterval 5000 L...

Page 422: ...n of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operand mode Specify 1 to enable the alarms 0 to disable the alarms If no operand is specified the default value is 0 alarms deactivated This operand is optional if omitte...

Page 423: ... command requires a Fabric Watch license The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To display the status of alarm filtering in Fabric Watch switch user fwalarmsfiltershow FW Alarms are enabled switch user fwalarmsfilte...

Page 424: ...rator s Guide for a list of supported Fabric Watch classes NOTES This command requires a Fabric Watch license The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To initialize all classes under Fabric Watch switch admin fwclassi...

Page 425: ...nfiguration file from a host NOTES This command requires a Fabric Watch license The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To reload the saved Fabric Watch configuration switch admin fwconfigreload fwConfigReload Fabric...

Page 426: ...cade DCX and DCX 4S chassis and on the Brocade 5300 switch The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operand show Displays the current FRU configuration setting This operand is optional if omitted the ...

Page 427: ...S Command Reference 393 53 1001764 01 fwFruCfg 22 WWN Alarm State 0 31 1 WWN Alarm Action 0 17 1 SFP Alarm State 0 19 0 SFP Alarm Action 0 17 0 Fru configuration left unchanged SEE ALSO fwHelp fwMailCfg sfpShow ...

Page 428: ...d Reload Fabric Watch configuration fwfrucfg Configure FRU state and notification fwhelp Print Fabric Watch help info fwmailcfg Configure Fabric Watch Email Alert fwportdetailshow Create a report with detailed port information fwsamshow Show availability monitor information fwset Set port persistence time fwsettocustom Set boundary alarm level to custom fwsettodefault Set boundary alarm level to d...

Page 429: ... F FL Port Optical class F FL Port Copper class embedded platforms only Resource class For an e mail alert to function correctly add the CP0 and CP1 IP addresses and host names to DNS and also set the domain name and name server The ipAddrShow and dnsConfig commands can be used to set and verify this information NOTES This command requires a Fabric Watch license The execution of this command is su...

Page 430: ...ss 6 F FL Port Optical class 7 Alpa Performance Monitor class 8 End to End Performance Monitor class 9 Filter Performance Monitor class 10 Security class 11 Resource Monitor class 12 FRU Class 13 Quit Select an item 0 13 11 1 Mail To NONE dino switchcorp com sys switchcorp com info switchcorp com dduck disneyland com mm gmail com Email Alert configuration succeeded To configure Fabric Watch e mail...

Page 431: ...w Mail Configuration Information 2 Disable Email Alert 3 Enable Email Alert 4 Send Test Mail 5 Set Recipient Mail Address for Email Alert 6 Quit Select an item 1 6 6 5 Mail Config Menu ___________________________ 1 Environment class 2 SFP class 3 Port class 4 F FL Port Optical class 5 Resource class 6 Quit Select an item 1 6 6 1 Mail To NONE jpaul brocade com Email Alert configuration succeeded SE...

Page 432: ...rences exceeding the limit for the time period PER The number of protocol errors exceeding the limit for the time period INW The number of invalid words exceeding the limit for the time period CRC The number of invalid CRC errors exceeding the limit for the time period PSC The port hardware state changed too often BLP Buffer limited port SFP Errors STM The SFP temperature is out of range SRX The S...

Page 433: ...detail report for the specified port s portState Displays a port detail report for the specified portState Valid portState entries include the following h Report based on all healthy ports m Report based on all marginal ports f Report based on all faulty ports o Report based on all offline ports EXAMPLES To retrieve a port detail report for a switch configured with an IPv6 address switch user fwpo...

Page 434: ... fwportdetailshow s h Port Detail Report Report time 05 21 2007 11 22 58 PM Switch Name switch IP address 192 168 163 237 Port Exception report by Healthy Port Errors Port Type State Dur H M LFA LSY LSI PER INW 001 F HEALTHY 409 09 014 F HEALTHY 409 09 015 E HEALTHY 409 09 SFP Errors CRC PSC BLP STM SRX STX SCU SVO SEE ALSO switchStatusShow ...

Page 435: ...n Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details This command requires a Fabric Watch license OPERANDS None EXAMPLES To generate a SAM report on an eighty port switch switch user fwsamshow Total Total Port Type Up Time Down Time Occurrence Offline Time Percent Percent Times Percent 0 U 0 0 0 100 1 U 0 0 0 100 2 U...

Page 436: ...portThconfig to display port persistence time NOTES This command requires a Fabric Watch license The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands port persistence seconds Specifies the time in second...

Page 437: ...ues Use the advanced configuration option provided with the portThConfig thConfig and sysMonitor commands to view and modify custom and default values for specified classes and areas in Fabric Watch For specific configuration procedures refer to the Fabric Watch Administrator s Guide NOTES This command requires a Fabric Watch license The execution of this command is subject to Virtual Fabric or Ad...

Page 438: ...pplied ActLevel Def High Custom TimeBase None Value 110 Trigger Above Action Raslog SNMP Trigger Below Action Raslog Default TimeBase None Value 90 Trigger Above Action Raslog SNMP Trigger Below Action Raslog Low Custom TimeBase None Value 15 Trigger Above Action None Trigger Below Action Raslog SNMP Default TimeBase None Value 0 Trigger Above Action None Trigger Below Action Raslog SNMP Buffer Cu...

Page 439: ... commands to view and modify custom and default values for specified classes and areas in Fabric Watch For specific configuration procedures refer to the Fabric Watch Administrator s Guide NOTES This command requires a Fabric Watch license The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and App...

Page 440: ...e Value 110 Trigger Above Action Raslog SNMP Trigger Below Action Raslog Default TimeBase None Value 90 Trigger Above Action Raslog SNMP Trigger Below Action Raslog Low Custom TimeBase None Value 15 Trigger Above Action None Trigger Below Action Raslog SNMP Default TimeBase None Value 0 Trigger Above Action None Trigger Below Action Raslog SNMP Buffer Custom Value 20 Default Value 0 SEE ALSO fwSet...

Page 441: ... switch If the HA feature is already disabled this command does nothing NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To disable the High Availability feature switch admin hadisable HA is disabled SEE ALSO haEnable h...

Page 442: ...nd health diagnostic has not detected any errors Failed The standby CP is running but the background health diagnostic has discovered a problem with the blade Check the logs to determine an appropriate course of action Failover is disabled until the standby CP is repaired Information about the failing device in the standby CP is displayed Unknown The standby CP health state is unknown because the ...

Page 443: ...te synchronized CHASSIS Ethernet IP Address 10 20 114 57 Ethernet Subnetmask 255 255 240 0 CP0 Ethernet IP Address 10 20 114 58 Ethernet Subnetmask 255 255 240 0 Host Name cp0 Gateway IP Address 10 20 112 1 CP1 Ethernet IP Address 10 20 114 59 Ethernet Subnetmask 255 255 240 0 Host Name cp1 Gateway IP Address 10 20 112 1 Backplane IP address of CP0 10 0 0 5 Backplane IP address of CP1 10 0 0 6 IPv...

Page 444: ...nd is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To enable the High Availability feature on a Brocade DCX 85120 8 switch admin haenable Warning This command will enable the HA It will reboot the standby CP and require all telnet secure telnet and SSH s...

Page 445: ...o flow This command is supported only on dual CP systems The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To force the failover of the active CP to the standby CP in the switch switch admin hafailover Local CP Slot 7 CP1 Acti...

Page 446: ... CP does not exist Heartbeat is down or the Health Monitor has detected a configuration file error The High Availability synchronization status is defined as follows HA State synchronized The system is currently fully synchronized If a failover becomes necessary it is nondisruptive HA State not in sync The system is unable to synchronize the two CPs This may be caused by one or more of the followi...

Page 447: ...one EXAMPLES To display CP status on a Brocade DCX 8510 8 with a healthy standby CP switch admin hashow Local CP Slot 7 CP1 Active Warm Recovered Remote CP Slot 6 CP0 Standby Healthy HA Enabled Heartbeat Up HA State Synchronized SEE ALSO haDisable haEnable haFailover ...

Page 448: ...eboot the active CP reboot the standby CP insert a new standby CP blade or issue the haSyncStart command The time it takes for the HA sync to complete depends on the system configuration The HA sync timeout is set to 10 minutes NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix ...

Page 449: ...insert a new standby CP blade or issue the haSyncStart command The time it takes for the HA sync to complete depends on the system configuration The HA sync timeout is set to 10 minutes NOTES Disabling HA synchronization may cause failover to be disruptive The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS...

Page 450: ...form To access help information for a specific command enter the command name as an operand Commands ending in Help display grouped commands for a particular subsystem for example the diagHelp command displays a list of diagnostic commands OPERANDS This command has the following operands command Specifies the name of the command for which to display help information This operand is optional p page...

Page 451: ...nced Performance Tuning policy auditcfg Modifies and displays audit log filter configuration auditdump Display audit log authutil Get and set configuration backplanetest Backplane connection test for multi blade systems backport Test for back end ASIC pair to ASIC pair links bannerset Set security banner bannershow Display security banner bcastshow Display broadcast routing information Type CR or ...

Page 452: ...e shell history mechanism is similar to the UNIX shell history facility The h command displays the 20 most recent commands typed into the shell the oldest commands are replaced as new ones are entered OPERANDS None EXAMPLES To display previous shell commands switch admin h 1 version 2 switchshow 3 portdisable 2 4 portenable 2 5 switchshow SEE ALSO None ...

Page 453: ... all other object types Event type Inserted Removed or Invalid Time of the event Format Day Month dd hh mm ss yyyy The second and third lines of a record contain the factory part number and factory serial number if applicable Factory Part Number xx yyyyyyy zz or Not available Factory Serial Number xxxxxxxxxxxx or Not available The size of the history log depends on the hardware platform The Brocad...

Page 454: ...um buffer size is discarded The original entries in the buffer is preserved The history mode is a factory setting that cannot be modified The size of the history buffer depends on the hardware platform The Brocade DCX backbone supports a maximum log size of 50 entries Because the WWNs are completely separate FRUs in the DCX they have redundant data in these units All other platforms containing FRU...

Page 455: ... event Format Day Month dd hh mm ss yyyy The second and third lines of a record contain the factory part number and factory serial number if applicable Factory Part Number xx yyyyyyy zz or Not available Factory Serial Number xxxxxxxxxxxx or Not available The size of the history buffer depends on the HW platform The Brocade DCX supports a maximum log size of 50 entries Because the WWNs are complete...

Page 456: ... 0001532 03 Factory Serial Number 1013456800 CP BLADE Slot 6 Removed at Tue Aug 14 13 45 07 2001 Factory Part Number 60 0001604 02 Factory Serial Number FP00X600128 SW BLADE Slot 3 Inserted at Tue Aug 14 13 53 40 2001 Factory Part Number 60 0001532 03 Factory Serial Number 1013456800 CP BLADE Slot 6 Inserted at Tue Aug 14 13 59 50 2001 Factory Part Number 60 0001604 02 Factory Serial Number FP00X6...

Page 457: ...ent warning messages STARTING 002 being created EXITING 004 getting shut down PTRACED 010 set if ptrace 0 has been called TRACESYS 020 tracing system calls FORKNOEXEC 040 forked but did not exec SUPERPRIV 100 used super user privileges DUMPCORE 200 dumped core SIGNALED 400 killed by a signal S Process state codes D Uninterruptible sleep usually IO R Runable on run queue S Sleeping T Traced or stop...

Page 458: ...r no controlling terminal TIME The cumulative execution time for the process CMD The command name of the process NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operand processID Specifies the process ...

Page 459: ...1 Using Fabric OS Commands and Appendix A Command Availability for details This command must be executed on the active CP OPERANDS This command has the following operands slot Specifies the slot number of the ICL group to be enabled or disabled followed by a slash The slot on the DCX can be either 5 or 8 On the DCX 4S valid slots are 3 and 6 icl_group Specifies the ICL port group to be disabled or...

Page 460: ...Reference 53 1001764 01 iclCfg 22 To disable the ICL for ports 16 31 persistently switch user iclcfg persistentdisable 8 1 To enable the ICL for ports 16 31 persistently switch user iclcfg persistentdnable 8 1 SEE ALSO None ...

Page 461: ... message and prompts for verification before continuing This warning is not displayed and you are not prompted when the command is used through the serial console port For dual CP systems the ifModeSet command affects only the CP you are currently logged in to To set the link operating mode on the active CP you must issue this command on the active CP to set the link operating mode on the standby ...

Page 462: ...ting configuration done To force the link for the eth0 interface from autonegotiation to 10 Mbps half duplex operation when entering this command through the serial console port switch admin ifmodeset eth0 Auto negotiate yes y no n yes n Force 100 Mbps Full Duplex yes y no n no n Force 100 Mbps Half Duplex yes y no n no n Force 10 Mbps Full Duplex yes y no n no n Force 10 Mbps Half Duplex yes y no...

Page 463: ...ed over it When the active Ethernet port is disconnected the alternate Ethernet port becomes active When the system reboots the Ethernet port eth0 is always made active if it is connected When executed with the bond0 operand ifModeShow displays the active Ethernet port NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapte...

Page 464: ...430 Fabric OS Command Reference 53 1001764 01 ifModeShow 22 To display the active interface ras010 root ifmodeshow bond0 Currently Active Slave eth0 SEE ALSO ifModeSet ...

Page 465: ... the trunk master port if present of the trunk group of which this port is a part defaultCost Default cost of sending a frame over the interswitch link ISL connection to this interface cost Cost of sending a frame over the ISL connected to this interface A value of 1000 indicates a 1 Gbps link A value of 500 indicates a 2 Gbps link For links with a bandwidth greater than 2 Gbps the cost is 500 For...

Page 466: ...remote switch connected to this port nflags Internal FSPF flags initCount Number of times this neighbor was initialized without the interface going down lastInit Time of the last initializing state NB_ST_INIT on this interface firstHlo Time of the first hello sent on this interface nbstFull Time of the last finishing state NB_ST_FULL on this interface dbRetransList Pointer to the database retransm...

Page 467: ...eived from the neighbor switch nLsaIn Number of LSAs received from the neighbor switch attHloOut Number of attempted transmissions of Hello frames to the neighbor switch nHloOut Number of Hello frames transmitted to the neighbor switch attLsuOut Number of attempted transmissions of LSUs to the neighbor switch nLsuOut Number of LSUs transmitted to the neighbor switch attLsaOut Number of attempted t...

Page 468: ... 458 upCount 2 lastUpTime Apr 02 20 01 44 458 downCount 1 lastDownTime Apr 02 20 01 09 050 downReason 2 iState UP Neighbor 4 data structure state NB_ST_FULL lastTransition Apr 02 20 01 44 512 nghbCap 0x0 nghbId 100 idbNo 4 remPort 52 nflags 0xf initCount 1 lastInit Apr 02 20 01 44 460 firstHlo Apr 02 20 01 44 473 nbstFull Apr 02 20 01 44 512 delay 1 lastScn 16 dbRetransList 0x1008c6a0 lsrRetransLi...

Page 469: ...Fabric OS Command Reference 435 53 1001764 01 interfaceShow 22 nHloOut 2 attLsuOut 3 nLsuOut 3 attLsaOut 2 nLsaOut 2 SEE ALSO nbrStateShow portShow switchShow ...

Page 470: ... This command disables the legacy IOD enforcement only Disabling IOD allows faster rerouting after a fabric topology change but it may cause out of order delivery of frames during fabric topology changes NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability f...

Page 471: ...lso means that frames are dropped during the delay causing I O failures When used without operands iodSet enables in order delivery of frames on a switch legacy IOD behavior Frame loss is unavoidable when a port goes down IOD is disabled by default Use iodShow to display current settings Use iodReSet to restore the default setting NOTES You can no longer use this command to manage Lossless DLS Use...

Page 472: ... on the switch By default IOD is disabled NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To display the current setting of the IOD setting switch admin iodshow IOD is not set SEE ALSO iodReset iodSet ...

Page 473: ...sis Command usage depends on the type of IP address and on the platform on which the command is run Some of the platform and IP address specific features of the command are outlined below For complete details refer to the Fabric OS Administrator s Guide Configuring IP Addresses using the command line interface The command accepts the ipv6 command line syntax with the add or delete option on all pl...

Page 474: ...y if invoked without operands The command prompts for the Ethernet IP address Ethernet subnet mask and Gateway IP address In addition the command prompts for a specification of whether the Dynamic Host Control Protocol DHCP should be used to acquire the Ethernet IP address Ethernet subnet mask and Gateway IP address Valid entries are On to enable DHCP and Off to disable it When DHCP is enabled any...

Page 475: ...ired with the add option delete Deletes the IPv4 FC address and prefix from a logical switch ls IFID Specifies the fabric ID that identifies the logical switch for which to delete the FC IPv4 address and prefix This operand is required when deleting an FC IPv4 address from a logical switch On a switch that is not in Virtual Fabric mode use the ls parameter with FID 128 the effective single Logical...

Page 476: ...2 3 4 24 Backplane IP address of CP0 10 0 0 5 Backplane IP address of CP1 10 0 0 6 To delete the IPv4 address for the IPFC interface associated with a logical switch with Virtual Fabric ID 67 switch admin ipaddrset ls 67 delete IP address is being changed Done To configure an IPv4 FC address for the IPFC interface associated with a switch that is not in Virtual Fabric mode switch admin ipaddrset l...

Page 477: ...3 53 1001764 01 ipAddrSet 22 To enable DHCP on a standalone non AP platform switch admin ipaddrset Ethernet IP Address 192 168 74 102 Ethernet Subnetmask 255 255 255 0 Gateway IP Address 192 168 74 1 DHCP Off on SEE ALSO ipAddrShow ...

Page 478: ...t mask The Gateway IP Address Dynamic Host Control Protocol DHCP on or Off Pv6 Autoconfiguration Enabled Yes or No Local IPv6 Addresses On modular platforms the command displays the following information For the chassis Ethernet IP Address Ethernet Subnet mask For each CP Ethernet IP Address Ethernet Subnet mask Host Name Gateway IP Address If the IPFC network interface is configured for logical s...

Page 479: ...e eth0 eth1 gate For a specified slot shows only the selected Ethernet interface or the gateway This operand is optional with the slot option EXAMPLES To display the IP addresses on a standalone switch switch admin ipaddrshow SWITCH Ethernet IP Address 192 168 163 238 Ethernet Subnetmask 255 255 255 0 Gateway IP Address 192 168 163 1 DHCP Off IPv6 Autoconfiguration Enabled No Local IPv6 Addresses ...

Page 480: ...9bc 63 3 cp 0 fe80 60 69bc 63 1 cp 0 fe80 60 69bc 63 2 cp 1 fe80 60 69bc 63 1 cp 1 fe80 60 69bc 63 2 cp 1 fe80 60 69bc 63 3 To display the IP addresses for a chassis switch admin ipaddrshow chassis CHASSIS Ethernet IP Address 10 32 220 10 Ethernet Subnetmask 255 255 240 0 IPv6 Autoconfiguration Enabled Yes Local IPv6 Addresses chassis 0 stateless fd00 60 69bc 63 205 1eff fe39 e45a 64 preferred cha...

Page 481: ...ive configuration The active policy must be the default policy or one of the policies in the defined configuration Only the active policies are enforced All of the ipFilter options except show and transabort create a transaction owned by the management session initiating the commands An open transaction prevents other transactions from being created on different management sessions The create clon...

Page 482: ...ate set to modified defined or modified active save policyname Saves one or all IP filter policies persistently as the defined configuration This operand is optional If a policy name is specified only the specified IP filter policy in the temporary buffer is saved otherwise all IP filter policies in the temporary buffer is saved Only the CLI session that owns the updated temporary buffer can run t...

Page 483: ...address Forwarding rules manage the bidirectional traffic between the external Ethernet interface eth0 bond0 and the inband management interface inbd INPUT traffic is the default type of traffic for IP filter rules dip destination_IP Specifies the destination IP address For filters of type IPV4 the address must be a 32 bit address in dot notation or a CIDR style IPv4 prefix For filters of type IPv...

Page 484: ...tcp 600 1023 permit 12 any udp 600 1023 permit Name default_ipv6 Type ipv6 State active Rule Source IP Protocol Dest Port Action 1 any tcp 22 permit 2 any tcp 23 permit 3 any tcp 897 permit 4 any tcp 898 permit 5 any tcp 111 permit 6 any tcp 80 permit 7 any tcp 443 permit 8 any udp 161 permit 9 any udp 111 permit 10 any udp 123 permit 11 any tcp 600 1023 permit 12 any udp 600 1023 permit To activa...

Page 485: ...ype ipv4 To add a rule to the created policy ex2 switch admin ipfilter addrule ex2 sip 10 32 69 99 dp 23 proto tcp act permit To display the IP filter policies including the new policy switch admin ipfilter show Name default_ipv4 Type ipv4 State active Name default_ipv4 Type ipv4 State active Rule Source IP Protocol Dest Port Action 1 any tcp 22 permit 2 any tcp 23 permit 3 any tcp 897 permit 4 an...

Page 486: ...23 proto tcp act permit type fwd dip 10 32 69 90 switch admin ipfilter show a Legends Proto Protocol P Permit D Deny FWD FORWARD I P INPUT Name default_ipv4 Type ipv4 State active Rule Source_IP Proto Dest_Port Action Flow Destination_IP 1 any tcp 22 P I P any 2 any tcp 23 P I P any 3 any tcp 897 P I P any 4 any tcp 898 P I P any 5 any tcp 111 P I P any 6 any tcp 80 P I P any 7 any tcp 443 P I P a...

Page 487: ...e 453 53 1001764 01 ipFilter 22 12 any udp 600 1023 P I P any Name ex2 Type ipv4 State defined modified Rule Source_IP Proto Dest_Port Action Flow Destination_IP 1 10 32 69 99 tcp 23 P FWD 10 32 69 99 SEE ALSO policy distribute ...

Page 488: ...ram or only the upper layer protocols The appropriate modes are called tunnel mode and transport mode In tunnel mode the IP datagram is fully encapsulated by a new IP datagram using the IPSec protocol In transport mode only the payload of the IP datagram is handled by the IPSec protocol it inserts the IPSec header between the IP header and the upper layer protocol header The IPSec key management s...

Page 489: ...nding to the identity of the IKE peer or group of peers Use secCertUtil to import delete or display the preshared keys in the local switch database The MD5 hash algorithm is blocked when FIPS mode is enabled Refer to the Examples section for specific use cases and associated command sequences Refer to the Fabric OS Administrator s Guide for configuration procedures This command accepts abbreviated...

Page 490: ... direction in out Specifies traffic flow direction as inbound or outbound local IP_address prefixlength Specifies the source IPv4 or IPv6 address remote IP_address prefixlength Specifies the peer IPv4 or IPv6 address transform name Specifies the transform to be included in the selector You must create the transform before you can use in the selector Use ipsecConfig show policy ips transform to dis...

Page 491: ...so be defined sa proposal Defines the security associations SA proposal including name SAs to be included and lifetime of the proposal The following operands are supported tag name Specifies a name for the SA proposal This is a user generated name The name must be between 1 and 32 characters in length and may include alphanumeric characters dashes and underscores _ sa name name Specifies the SAs t...

Page 492: ...ed Valid algorithms include the following 3des_cbc 3DES encryption algorithm blowfish_cbc Blowfish encryption algorithm null_enc Null encryption algorithm aes256_cb AES 256 algorithm spi number Specifies the security parameter index SPI for the SA This is a user defined index Valid SPI numbers consist of numeric characters 0 9 This operand is optional policy ike Creates or modifies an IKE policy c...

Page 493: ...rithm null_enc Null encryption algorithm cleartext hash algorithm Specifies the hash algorithm Valid hash algorithms include the following hmac_md5 MD5 algorithm hmac_sha1 SH1 algorithm prf algorithm Specifies the PFR algorithm Valid PRF algorithms include the following hmac_md5 MD5 algorithm hmac_sha1 SH1 algorithm auth psk dss rsasig Specifies the authentication method as one of the following ps...

Page 494: ...d a new key is generated for keying the SAs Enabling PFS may provide enhanced protection against keys compromise version 1 2 Specifies the IKE version This operand is optional If not specified IKEv2 is used 2 If 1 is specified IKEv1 is selected Use v 2 to revert to version 2 after version 1 was set manual sa Creates manually keyed SADB entries When using this option you must generate the keys manu...

Page 495: ... algorithm Valid encryption algorithms include the following 3des_cbc 3DES algorithm null_enc Null encryption algorithm cleartext auth algorithm Specifies the authentication algorithm Valid authentication algorithms include the following hmac_md5 MD5 algorithm hmac_sha1 SH1 algorithm enc key number Specifies the encryption key This is a user generated key based on the length of the key Use the LIN...

Page 496: ...icies sa proposal Deletes the SA proposal for a specified IPSec policy or all SA proposals of all configured IPSec policies sa Deletes the SAs for a specified IPSec policy or all SAs of all configured IPSec policies policy ike Deletes a specified IKE policy or all configured IKE policies sa Deletes a specified SADB entry or all manual SADB entries manual sa Deletes the SA policy entries used in ma...

Page 497: ...ocol used AH or ESP encryption and authentication algorithms policy ike Displays the IKE policy configuration No subtype is required with this command The command displays the following IKE policy parameters IKE version IP address of the remote entity IP address of the local entity encryption algorithm hash algorithm PRF algorithm DH group authentication method path and filename of the preshared k...

Page 498: ...ic selectors to select the outbound and inbound traffic that needs to be protected switch admin ipsecconfig add policy ips selector t SELECTOR OUT d out l 10 33 74 13 r 10 33 69 132 transform TRANSFORM01 switch admin ipsecconfig add policy ips selector t SELECTOR IN d in l 10 33 69 132 r 10 33 74 13 transform TRANSFORM01 9 Verify the IPSec SAs created using IKE for above traffic flow using ipsecCo...

Page 499: ...ure an IKE policy for the remote peer UNIX host switch admin ipsecconfig add policy ike t IKE01 remote fe80 205 1fff fe51 f09e id fe80 220 1aff fe34 2e82 remoteid fe80 205 1fff fe51 f09e enc 3des_cbc hash hmac_md5 prf hmac_md5 auth rsasig dh modp1024 pubkey Brocade300 pem privkey Brocade300 key pem peerpubkey remote peer pem 8 Create an IPSec transform TRANSFORM01 to use transport mode to protect ...

Page 500: ...seckey psk using the secCertUtil import command 6 Create an IKE policy for the remote peer switch admin ipsecconfig add policy ike t IKE01 remote 10 33 69 132 id 10 33 74 13 remoteid 10 33 69 132 enc 3des_cbc hash hmac_md5 prf hmac_md5 auth psk dh modp1024 psk ipseckey psk 7 Create an IPSec transform TRANSFORM01 configured with transport mode to protect traffic identified for IPSec protection and ...

Page 501: ...ec configuration Refer to your server administration guide for instructions IPSec display commands To display the IPSec IKE Policy switch admin ipsecconfig show policy ike a IKE 01 version ikev2 remote 10 33 69 132 local id 10 33 74 13 remote id 10 33 69 132 encryption algorithm 3des_cbc hash algorithm hmac_md5 prf algorithm hmac_md5 dh group 2 1 auth method rsasig public key etc fabos certs sw0 t...

Page 502: ...ite To display all IPSec transforms switch admin ipsecconfig show policy ips transform a policy A B action auto_ipsec mode transport local 10 33 69 132 remote 10 33 74 13 sa proposal ipsec esp a b ike policy remote B To display all IPSec traffic selectors switch admin ipsecconfig show policy ips selector a slt A B any local 10 33 69 132 remote 10 33 74 13 direction outbound upper layer protocol an...

Page 503: ...M 3des_cbc aes128_cbc aes256_cbc null_enc HASH ALGORITHM hmac_md5 hmac_sha1 aes_xcbc PRF ALGORITHM hmac_md5 hmac_sha1 aes_xcbc DH GROUP modp768 1 modp1024 2 modp2048 14 modp8192 18 REFERENCES DISR DOD IPv6 Standards Profiles for IPv6 Capable Products v2 0 6 15 2007 NIST A Profile for IPv6 in the U S Government v1 0 1 31 2007 4301 Kent S and K Seo Security Architecture for the Internet Protocol RFC...

Page 504: ...SL XISL connects the base switches and is shared by different logical fabrics It allows devices to communicate with each other within the logical fabric Connection speed is not applicable to LE_Ports or VE_Ports For these port types speed displays as sp NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric...

Page 505: ...00 00 05 1e 37 02 73 43 B53000 sp bw 11 000G To display interswitch links with encryption or compression enabled switch user islshow 1 33 29 10 00 00 60 69 80 4f 84 3 B3200 sp 2 000G bw 4 000G TRUNK ENCRYPT 2 39 7 10 00 00 60 69 45 68 04 4 B3850 sp 2 000G bw 8 000G ENCRYPT COMPRESS 2 38 6 10 00 00 60 69 45 68 03 4 B3850 sp 2 000G bw 8 000G COMPRESS SEE ALSO switchShow trunkShow ...

Page 506: ...ons on the slot numbers Once specified a slot selection applies to all items to the right of the slot selections until the next slot selection or the end of the item list For example 1 0 15 and 1 0 1 15 are equivalent If no slot number is specified user port lists are specified by area number For instance 0 16 32 and 1 0 2 0 3 0 specify the same ports on a 16 port blade system On that same system ...

Page 507: ...e is one of the following Type Grouping Description ______________________________________________________________ BPORTS Blade Blade ports internal and external ports UPORTS Switch User ports ports with external connections QUADS Blade Quadrants group of normally 4 ports CHIPS Blade Chips Asics within a blade MINIS Blade Mini switches SLOTS Chassis Slots INDEX N A Anything NOTES The execution of ...

Page 508: ...tch admin killtelnet Collecting login information Done List of telnet sessions 3 found ________________________________________________________________ Session No USER TTY IDLE FROM LOGIN 0 root0 ttyS0 1 17m 5 13pm 1 admin0 pts 0 16 00s 192 168 130 29 6 29pm 2 admin0 pts 1 3 00s 192 168 130 29 6 31pm Enter Session Number to terminate q to quit 1 Collecting process information Done You have opted t...

Page 509: ...D server to the admin role on the switch or the SAN maintenance role to the switch operator role But the command fails if you attempt to map an already mapped AD server role NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This comma...

Page 510: ...s the command usage EXAMPLES To display current LDAP and switch role map switch admin ldapcfg show LDAP Role Switch Role ldapadmin admin ldapuser user SANfabadmin fabricadmin SANzoneadmin zoneadmin SANoperator operator LDAPSANsecadm securityadmin SANuser user SAN01secadmin securityadmin LD_02zoneadmin zoneadmin To map an LDAP AD server role to the switch role of operator switch admin ldapcfg mapro...

Page 511: ...tions provided with this command show the logical fabric configuration for a given logical switch context or for a chassis context Each logical switch displays only the user ports that are configured to be part of that switch instance The switch context is defined by the fabric ID The default context is the base logical switch that you are placed in upon login The default logical switch context is...

Page 512: ... s Guide for specific hardware support You cannot use the portEnable command on logical ports Use lfcfg with the lislenable option to re enable disabled LISL ports on a logical switch OPERANDS This command has the following operands show cfg Displays information for the fabric ID set by the context in all chassis reachable from the base fabric showall cfg Displays information for all fabrics in al...

Page 513: ...e switch domain 2 Logical switch 2 Base switch YES Fabric Id 2 State Online 1 Switch WWN 10 00 00 05 1e 0b a4 41 To display information for all fabrics in all chassis reachable from the base fabric switch admin lfcfg showall cfg Chassis 1 Chassis WWN 10 00 00 05 1e 39 82 64 Number of Partitions 2 Base switch domain 1 Logical switch 2 Base switch YES Fabric Id 2 State Online 1 Switch WWN 10 00 00 0...

Page 514: ...5 1e 58 b2 5a 451 20 PortOnline 10 00 00 05 1e 48 f8 03 10 00 00 05 1e 58 b2 5b 452 30 PortOnline 10 00 00 05 1e 48 f8 04 10 00 00 05 1e 5b 69 d5 453 10 PortOnline 10 00 00 05 1e 48 f8 02 10 00 00 05 1e 5b 69 d4 454 30 PortOnline 10 00 00 05 1e 48 f8 04 10 00 00 05 1e 58 bd 6b 455 10 PortOnline 10 00 00 05 1e 48 f8 02 10 00 00 05 1e 58 bd 6a XISL Port No 12 31 LISL Pt FID LISL State Local LS WWN R...

Page 515: ...ed product is generally available immediately without requiring a system reboot The following exceptions apply When adding a fabric license to a switch that lacks a fabric license you must reboot the switch to activate the license When adding a trunking license to the switch you must refresh the trunk ports to activate the trunking license Depending on your system use the portDisable portEnable sw...

Page 516: ... may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To display license commands switch admin licensehelp licenseadd Adds license keys to switch licensehelp Prints license help info licenseidshow Displays the system license ID licenseremove Removes a license key from this system licenseshow Displays current license keys...

Page 517: ... pairs of hexadecimal values separated by colons Each hexadecimal value is between 00 0 and FF 255 NOTES While the format of this identifier might be similar or even identical to other identifiers in the system no inferences should be made about the relationships between them as they are subject to change independently of one another The execution of this command is subject to Virtual Fabric or Ad...

Page 518: ...ynamic assignments by reserving assignments for specific ports in the event that there are more online ports than the purchased POD licenses can support NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details This command is valid only on embedded p...

Page 519: ...cense 0 4 9 12 13 16 17 18 20 21 23 Ports assigned to the second POD license None Ports not assigned to a license 22 1 license reservation is still available for use by unassigned ports To reserve a Dynamic POD license assignment for a port and to display the assignments switch admin licenseport reserve 5 switch admin switch admin licenseport show 24 ports are available in this switch 1 POD licens...

Page 520: ...ePort 22 To disable Dynamic Ports On Demand switch admin licenseport method static The POD method has been changed to static Please reboot the switch now for this change to take effect SEE ALSO licenseAdd licenseHelp licenseRemove licenseShow licenseShow ...

Page 521: ...1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS The following operand is required license Specifies the license key to be removed or deactivated This operand is required EXAMPLES To remove a license key from the switch switch admin licenseremove bQebzbRdScRfc0iK removing license key bQebzbRdScRfc0iK To deactivate a slot based license switch admin licenseremove D...

Page 522: ...t license XFJXYHmPtCWC93CLgBD9BZD9AmTFgDStFDJGMaLKC9FgWAfgSE 8 Gig FC license Expiry Date 03 06 2009 License is expired Hf7MBEEGCFNmTAWXXF99RtHXQN4RRtM3mLGtrWZLAMaTaAY9EB Storage Application Services license Expiry Date 03 07 2009 SEE ALSO licenseAdd licenseHelp licenseIdShow licenseShow ...

Page 523: ...ense installed on this switch is displayed NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details On the Brocade DCX and DCX 8510 chassis family running Fabric OS v7 0 0 and later the interchassis link ICL license is displayed as an ICL Ports on De...

Page 524: ...License is expired H47CFSa93aKgKJM9NWMYEMaLrATQWDHCgHfZftWGGgNCYAJaBA High Performance Extension over FCIP FC license Expiry Date 12 20 2008 To display a slot based 10G FC and 10G Gigabit Ethernet license on a Brocade DCX 8510 8 switch admin licenseshow tKLFTNAPDQtEPHFCf9YSPrafrTJCQALP49fXEGHA4SPB 10 Gigabit FCIP Fibre Channel FTR_10G license Capacity 3 Consumed 3 Configured Blade Slots 1 3 12 swi...

Page 525: ...ore and after a firmware upgrade to Fabric OS v7 0 0 switch admin licenseshow X3ffNTZM9CNmM4SKFLYTGS4WmCRCgAZZBJDTB Inter Chassis Link 16 link license switch admin licenseshow X3ffNTZM9CNmM4SKFLYTGS4WmCRCgAZZBJDTB Inter Chassis Link 16 link license SEE ALSO licenseAdd licenseHelp licenseIdShow licenseRemove ...

Page 526: ...data replication operations over distance A license key with the specified capacity must be installed with the licenseAdd command before you can enable the feature on a specified slot with the licenseSlotCfg command Refer to the Fabric OS Administrator s Guide for more information NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Ref...

Page 527: ...73rP9GANJMA Advanced Extension FTR_AE license Capacity 8 Consumed 0 To configure the blade slots 3 4 11 and 12 to enable the license on these slots switch admin licenseslotcfg add FTR_AE 3 Blade slot 3 added to FTR_AE slot based license configuration Remaining capacity for FTR_AE slot based license 7 switch admin licenseslotcfg add FTR_AE 4 Blade slot 4 added to FTR_AE slot based license configura...

Page 528: ...R_AFA license blade slots configured 3 4 switch admin licenseslotcfg remove FTR_AE 12 Blade slot 12 removed from FTR_AE slot based license configuration switch admin licenseslotcfg show FTR_10G license blade slots configured 1 3 5 12 FTR_AFA license blade slots configured 3 4 switch admin licenseshow SSezcSec9RXTf0dj Performance Monitor license KgrfCBHgRtfBrGKH4D7f9S3FBX7K3MtTtBHKrYHA4CMB 10 Gigab...

Page 529: ...umed 4 Configured Blade Slots 1 3 5 12 A7N9rATZLYgFa7JBfmGEJKETgCMHFGQMY4gfLmGAa4GA Advanced FICON Acceleration FTR_AFA license Capacity 6 Consumed 2 Configured Blade Slots 3 4 DXXtN3LmRSMWCSW3XmfSBPfrWKLZ3HMTN73rP9GANJMA Advanced Extension FTR_AE license Inactive G4H3AZmW4gPTMHN9FfZJFGX4fSaTSY9TtaDCB43EBNHKYANSZA 10 Gigabit Ethernet FTR_10G license Inactive SBZNQ344YCLK4QaYXJ9SfPDR9FrSaXAT4WHNGmA...

Page 530: ...ommand is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details This command cannot be executed on a logical ISL LISL OPERANDS This command has the following operands slot For bladed systems only specifies the slot number for which to set or display the cost followed by a slash port Sp...

Page 531: ...L cost to a value outside of the recommended range switch admin linkcost 1 9 32766 The link cost entered may prevent some parts of the fabric from being accessible If you do not want this to happen choose n no and run linkcost again with a value lower than 32766 Do you want to continue yes y no n no y switch admin linkcost 1 9 Interface1 9 E_PORT Cost 32766 STATIC To set the ISL cost to the maximu...

Page 532: ...gh a Telnet or rlogin session that session is left open This command allows you to access commands that you cannot access at your current user level NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To log in as admin fr...

Page 533: ... this command to log out from a shell session Remote login connections are closed and the local serial connections return to the login prompt The exit command is accepted as a synonym for logout as is Ctrl D at the beginning of a line OPERANDS None EXAMPLES To log out from an rlogin session switch admin logout SEE ALSO login ...

Page 534: ...r each LSAN zone The default output displays only WWNs of the zone members Search parameters f w and z allow searching for LSAN zones based on fabric ID WWN of an LSAN zone member or LSAN zone name No LSAN zone found is displayed if there is no LSAN zone information available at this FC Router Each LSAN zone entry displays the following Fabric ID The ID of the fabric in which the LSAN zone was cre...

Page 535: ...hich can differ from the database stored on the other FCR switches EXAMPLES To display the LSAN zones switch admin lsanzoneshow Fabric ID 4 Zone Name lsan_fcr10_0 50 05 07 65 05 84 0b 83 50 05 07 65 05 84 09 0e 10 00 00 00 c9 2b 6a 68 21 00 00 20 37 18 22 55 Fabric ID 5 Zone Name lsan_fcr11_0 10 00 00 00 c9 2b 6a 68 21 00 00 20 37 18 22 55 50 05 07 65 05 84 0b 83 50 05 07 65 05 84 09 0e switch SEE...

Page 536: ...bric can scale independently The Default Logical Switch is created by the system and cannot be deleted All switch ports not explicitly assigned to a logical switch are part of the default logical switch The Virtual Fabric VF feature must be enabled on the switch before you can configure a logical switch Use the fosconfig enable vf command to enable the feature Use the fosconfig show command to det...

Page 537: ...Specifies the fabric ID of the logical switch This operand is required slot slot1 slot2 Specifies the slot number or a range of slot numbers separated by a dash for example slot 3 5 This operand is required port port1 port2 Specifies the ports to be assigned to the logical switch Provide a valid port or a range of ports separated by a dash for example port 3 8 This operand is optional if omitted a...

Page 538: ...d can be used with or without the ge option help Displays the command usage EXAMPLES To create a base switch switch admin lscfg create 1 base Creation of a base switch requires that the proposed new base switch on this system be disabled Would you like to continue y n y About to create switch with fid 1 Please wait Switch successfully created Logical Switch has been created with default configurat...

Page 539: ...nfig 2 port 0 4 force Configuration change successful Making this configuration change Please wait Please enable your ports switch when you are ready to continue To display the logical switch configuration for FC ports only switch admin lscfg show Created switches 128 ds 1 bs 2 Port 0 1 2 3 4 5 6 7 8 9 FID 1 1 1 1 1 1 1 1 2 2 Port 10 11 12 13 14 15 16 17 18 19 FID 128 128 128 128 128 128 128 128 1...

Page 540: ... for a logical switch switch admin lscfg change 1 newfid 2 Changing of a switch fid requires that the switch be disabled Would you like to continue y n y Disabling switch All active login sessions for FID 2 have been terminated Checking and logging message fid 2 Please enable your switch To display the change switch admin lscfg show Created switches 128 ds 1 2 bs Port 0 1 2 3 4 5 6 7 8 9 FID 1 1 1...

Page 541: ...posed new base switch Disabling switch fid 1 Please enable your switches when ready To make logical switch FID 1 the base switch with confirmation switch admin lscfg change 1 base Creation of a base switch requires that the proposed new base switch on this system be disabled Would you like to continue y n y Disabling the proposed new base switch Disabling switch fid 1 Please enable your switches w...

Page 542: ...n NB_ST_FULL state This command displays the content of both types of database entries if both are present as shown below Domain Domain ID described by this LSR A self keyword after the domain ID indicates that LSR describes the local switch lsrP Pointer to LSR earlyAccLSRs Number of LSRs accepted even though they were not sufficiently spaced apart ignoredLSRs Number of LSRs not accepted because t...

Page 543: ...f links in this LSR Each link represents a neighbor in NB_ST_FULL state flags Always 0 LinkId ID of this link It is the domain ID of the switch on the other side of the link out port Port number on the local switch rem port Port number of the port on the other side of the link cost Cost of this link The default cost for a 1 Gbps link is 1 000 costCnt Always 0 type Always 1 NOTES The execution of t...

Page 544: ... uOutIfsP 5 0x00000000 uOutIfsP 6 0x00000000 uPathCost 0 uOldHopCount 0 uHopsFromRoot 0 mOutIfsP 0 0x10000000 mOutIfsP 1 0x00000000 mOutIfsP 2 0x00000000 mOutIfsP 3 0x00000000 mOutIfsP 4 0x00000000 mOutIfsP 5 0x00000000 mOutIfsP 6 0x00000000 parent 0xf0 mPathCost 0 mHopsFromRoot 0 Link State Record Link State Record pointer 0x109784b0 lsAge 321 reserved 0 type 1 options 0x0 lsId 1 advertiser 1 inc...

Page 545: ...e Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands b Specify to display memory usage in bytes k Specify to display memory usage in kilobytes m Specify to display memory usage in megabytes By default memory usage is displayed in bytes EXAMPLES To view the memory usage switch admin memshow total used free sha...

Page 546: ...nd Appendix A Command Availability for details OPERANDS This command has the following optional operands set string Specify a text string of alphanumeric characters to be displayed before login The string must be enclosed in double quotation marks Spaces are allowed The maximum length is 116 characters show Displays the chassis wide banner help Displays the command usage EXAMPLES To set a chassis ...

Page 547: ...and Availability for details OPERANDS None EXAMPLES To display the supported MS capabilities for each switch in the fabric switch admin mscapabilityshow Switch WWN Capability Switch Name 10 00 00 60 69 20 15 71 0x0000008f switch1 10 00 00 60 69 00 30 05 0x0000008f switch2 Capability Bit Definitions Bit 0 Basic Config Service Supported Bit 1 Platform Management Service Supported Bit 2 Topology Disc...

Page 548: ...hanging the MS ACL by adding or deleting WWNs you are prompted to save the new configuration to nonvolatile storage The saved MS ACL becomes effective upon reboot The MS ACL is implemented on a per switch basis and should be configured on the switch to which the management application is directly connected NOTES When an FCS policy is enabled the MS ACL is not used In such a case access to MS is co...

Page 549: ... 60 15 0 Done 1 Display the access list 2 Add member based on its Port Node WWN 3 Delete member based on its Port Node WWN select 0 3 1 0 done SEE ALSO msCapabilityShow msPlatShow msPlClearDB msPlMgmtActivate msPlMgmtDeactivate msTdDisable msTdEnable msTdReadConfig secPolicyShow ...

Page 550: ...bric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To display the MS platform database for a fabric switch admin msplatshow Platform Name 9 first obj Platform Type 5 GATEWAY Number of Associated M A 1 Associated Management Addresses 35 http java sun com products plugin Number of Associated Node Names 1 Associated Node Names 10 00 00 60 69 20 15 71 Platform Name...

Page 551: ... restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To display the MS platform service database control block switch admin msplatshowdbcb Domain Worldwide Name Retry Count Exchange Status 3 10 00 00 60 69 51 10 e6 0 0x2 msPlDBCB peerWwn 00 00 00 00 00 00 00 00 msPlDBCB psPeerWwn 00 00 00 00 00 00 00 0...

Page 552: ...y from the primary FCS switch The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details This command is supported only in AD0 and AD255 contexts OPERANDS None EXAMPLES To clear the MS platform database switch admin msplcleardb MS Platform Service is current...

Page 553: ... command run msCapabilityShow to verify that all switches in the fabric support the MS platform service if one switch does not support the service the command fails When an FCS policy is enabled this command can be issued only from the primary FCS switch The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS C...

Page 554: ...abric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details This command is supported only in AD0 and AD255 contexts OPERANDS None EXAMPLES To deactivate the MS platform service on all switches in the fabric switch admin msplmgmtdeactivate MS Platform Service is currently enabled This will erase MS Platform Ser...

Page 555: ...ric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details This command is supported only in AD0 and AD255 contexts OPERANDS The following operand is optional ALL Disables the MS topology discovery service throughout the entire fabric This operand must be enclosed in double quotation marks EXAMPLES To disable th...

Page 556: ...primary FCS The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details This command is supported only in AD0 and AD255 contexts OPERANDS The following operand is optional ALL Enables the MS topology discovery service throughout the fabric This operand must b...

Page 557: ...overy service is enabled NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To display the status of the topology discovery service switch admin mstdreadconfig MS Topology Discovery is enabled SEE ALSO msCapabilityShow ms...

Page 558: ...he current login session for Telnet or the name of the current console port or the serial port if modem login used The current CP mode Active Standby or Unknown The current system status Redundant Nonredundant or Unknown NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Comma...

Page 559: ...emote Port E_Port interface on the remote switch State State of the neighbor The neighbor can be in one of the following five states 0 NB_ST_DOWN The neighbor is down 1 NB_ST_INIT The neighbor is initializing 2 NB_ST_DB_EX The neighbor and the switch are exchanging data from their Link State Records LSR databases 3 NB_ST_DB_ACK_WT The neighbor is waiting for the switch to acknowledge the LSR datab...

Page 560: ...aded systems Use switchShow to list valid ports This operand is optional if omitted all neighbor states are displayed EXAMPLES To display information about a neighbor directly connected to the local switch switch user nbrstateshow 2 0 Local Domain ID 1 Local Port Domain Remote Port State 16 2 48 NB_ST_FULL SEE ALSO interfaceShow ...

Page 561: ...mands and Appendix A Command Availability for details OPERANDS This command has the following operands slot For bladed systems only specify the slot number of the port to display followed by a slash port Specify the port number to display relative to its slot for bladed systems Use switchShow to list valid ports This operand is optional if omitted FSPF statistics are reset EXAMPLES To display the ...

Page 562: ... 01 nbrStatsClear 22 To verify the changes switch admin interfaceshow 1 0 idbP 0x10050a38 Interface 0 data structure nghbP 0x1004ce68 ifNo 0 masterPort 0 self defaultCost 500 cost 500 output truncated SEE ALSO interfaceShow portShow switchShow ...

Page 563: ...e real device s data The WWN must have eight colon separated fields each consisting of one or two hexadecimal numbers between 0 and ff with no spaces The PID must begin with 0x or 0X otherwise it is interpreted as an alias EXAMPLES To display all the device information matching the WWN 20 00 00 e0 8b 01 ce d3 switch user nodefind 20 00 00 e0 8b 01 ce d3 Remote Type Pid COS PortName NodeName NL 020...

Page 564: ...t Name 20 14 00 60 69 80 04 79 Permanent Port Name 22 00 00 04 cf 9f 78 7b Device type Physical Target Port Index 20 Share Area No Device Shared in Other AD No Aliases a320 NL 0314d5 3 22 00 00 04 cf 9f 7d e0 20 00 00 04 cf 9f 7d e0 0 FC4s FCP SEAGATE ST336605FC 0003 Fabric Port Name 20 14 00 60 69 80 04 79 Permanent Port Name 22 00 00 04 cf 9f 7d e0 Device type Physical Target Port Index 20 Share...

Page 565: ...ptional operands r Replaces the time to live TTL attribute output with state change registration SCR information This value indicates what type of RSCN a device registers to receive Values include the following SCR 0 Reserved SCR 1 Fabric detected registration Register to receive all RSCN requests issued by the fabric controller for events detected by the fabric SCR 2 NX_Port detected registration...

Page 566: ...0 00 01 10 00 00 00 00 00 00 01 na FC4s FCP PortSymb 41 Brocade Ioblaster Initiator 00 pid 10602 Fabric Port Name 20 06 00 05 1e 7a 7a 00 Permanent Port Name 20 06 00 05 1e 38 81 71 Port Index 6 Share Area No Device Shared in Other AD No Redirect No Partial No Aliases DeviceAlias The Local Name Server has 3 entries To display local NS information with aliases with the r option switch user nsaliass...

Page 567: ...e 38 81 71 Device type Physical Unknown initiator target Port Index 6 Share Area No Device Shared in Other AD No Redirect No Partial No Aliases MyAlias1 MyAlias2 N 010601 3 23 0d 00 05 1e 38 81 71 50 00 51 e3 88 17 10 0d 3 FC4s FCP PortSymb 44 Brocade Ioblaster Port Entity 00 pid 10601 Fabric Port Name 20 06 00 05 1e 7a 7a 00 Permanent Port Name 20 06 00 05 1e 38 81 71 Device type NPIV Unknown ini...

Page 568: ... has the following operand type Specifies the FC 4 type code to filter the command output Valid values are 0 to 255 Only the following two FC 4 device type codes are applicable to the Brocade environment 8 FCP type device 5 FC IP type device For all other codes entries are summarized in the format x ports supporting FC4 type where x is the number of ports and type is the user specified FC 4 type c...

Page 569: ...ue displayed is a domain ID domain address For example 0xfffc02 indicates domain 2 and is the domain on which the command has been executed This is the local domain and the information is stored locally by this switch cap_available Each switch in the fabric exchanges information regarding its capabilities for example firmware level feature support etc When the cap_available value is 1 it indicates...

Page 570: ...23 1 Device list count 8 Type Pid COS PortName NodeName N 5c1000 3 23 06 00 05 1e 53 e3 8a 50 00 51 e5 3e 38 a0 06 FC4s FCP PortSymb 45 Brocade VDPC Entity Slot 00 DPC 00 Entity 03 Fabric Port Name 20 10 00 05 1e 53 e3 8a Permanent Port Name 23 06 00 05 1e 53 e3 8a Port Index 16 Share Area No Device Shared in Other AD No Redirect No Partial No N 5c1200 3 23 04 00 05 1e 53 e3 8a 50 00 51 e5 3e 38 a...

Page 571: ... NodeName N 5c1000 3 23 06 00 05 1e 53 e3 8a 50 00 51 e5 3e 38 a0 06 FC4s FCP PortSymb 45 Brocade VDPC Entity Slot 00 DPC 00 Entity 03 Fabric Port Name 20 10 00 05 1e 53 e3 8a Permanent Port Name 23 06 00 05 1e 53 e3 8a Device type Virtual Unknown initiator target Port Index 16 Share Area No Device Shared in Other AD No Redirect No Partial No N 5c1200 3 23 04 00 05 1e 53 e3 8a 50 00 51 e5 3e 38 a0...

Page 572: ...e can support multiple CoS levels PortName Displays the device port world wide name WWN NodeName Displays the device node WWN TTL Displays the time to live in seconds for cached entries or NA not applicable if the entry is local SCR Displays the state change registration of the device This field displays only with the r option Device type Displays the device type if t is specified Fabric Port Name...

Page 573: ...e to live TTL attribute output with state change registration SCR information This value indicates what type of RSCN a device registers to receive Values include the following SCR 0x00000000 Reserved SCR 0x00000001 Fabric detected registration Register to receive all RSCN requests issued by the fabric controller for events detected by the fabric SCR 0x00000002 NX_Port detected registration Registe...

Page 574: ...ort Name 20 01 00 05 1e 34 00 70 Permanent Port Name 21 00 00 e0 8b 13 08 10 Port Index 1 Share Area No Device Shared in Other AD No Redirect No Partial No N 010e00 3 21 00 00 e0 8b 12 8a be 20 00 00 e0 8b 12 8a be na FC4s FCP NodeSymb 41 QLA2340 FW v3 03 06 DVR v9 0 0 2 w32 IP Fabric Port Name 20 0e 00 05 1e 34 00 70 Permanent Port Name 21 00 00 e0 8b 12 8a be Port Index 14 Share Area No Device S...

Page 575: ... 21 00 00 e0 8b 13 08 10 20 00 00 e0 8b 13 08 10 0x00000001 FC4s FCP NodeSymb 41 QLA2340 FW v3 03 06 DVR v9 0 0 2 w32 IP Fabric Port Name 20 01 00 05 1e 34 00 70 Permanent Port Name 21 00 00 e0 8b 13 08 10 Device type Physical Initiator Port Index 1 Share Area No Device Shared in Other AD No Redirect No Partial No N 010e00 3 21 00 00 e0 8b 12 8a be 20 00 00 e0 8b 12 8a be 0x00000001 FC4s FCP NodeS...

Page 576: ...ort NL NL_Port Pid The 24 bit Fibre Channel address COS A list of classes of service supported by the device PortName The device s port world wide name WWN NodeName The device s node WWN Permanent Port Name The physical N_Port or NL_Port WWN DeviceType The device type Port Index The index of the port to which the device is attached Shared Area Whether or not the device shares an area with other de...

Page 577: ...0 00 20 37 d9 6b b3 20 00 00 20 37 d9 6b b3 0 FC4s FCP SEAGATE ST318304FC 0005 Fabric Port Name 20 06 00 60 69 50 06 78 Permanent Port Name 22 00 00 20 37 d9 6b b3 Device type Physical Target NL 0416e4 3 22 00 00 20 37 d9 61 ac 20 00 00 20 37 d9 61 ac 0 FC4s FCP SEAGATE ST318304FC 0005 Fabric Port Name 20 06 00 60 69 50 06 78 Permanent Port Name 22 00 00 20 37 d9 61 ac Device type Physical Target ...

Page 578: ...evice s online zoned device data switch admin nszonemember a Port 4 Pid 0xb00400 Aliases ix360_131_201_6a Zoned Members 2 devices Pid 0xb00400 Aliases ix360_131_201_6a Pid 0xba1ee8 Aliases trimm101b_3 Port 12 Pid 0xb00c01 Aliases dl360_130159a Zoned Members 2 devices Pid 0xb00c01 Aliases dl360_130159a Pid 0xbd1bef Aliases nstor4b_8 Port 13 Pid 0xb00d00 Aliases ix360_131_196p5 Zoned Members 2 devic...

Page 579: ...tween minlength and 40 characters long The minlength parameter is set with the passwdCfg command Password may not contain the colon character Password must satisfy repeated and sequential character constraints The password history policy is enforced across all user accounts when the user is setting his own password The password history policy is not enforced when an administrator sets a password f...

Page 580: ...nostic information RADIUS enabled error Password change disallowed RADIUS authentication is enabled Password error Password length strength or history policy not met User is not a valid user name You have not specified a valid recognized user name on the system Permission denied You do not have permission to change the password for the specified user Incorrect password You have not entered the cor...

Page 581: ...swd Changing password for admin Enter new password Re type new password Password changed Saving password to stable storage Password saved to stable storage successfully To change the password for user admin from an admin account noninteractively switch admin passwd old password new adminpass Password changed Saving password to stable storage Password saved to stable storage successfully To change ...

Page 582: ...d the password set by the administrator is recorded in the user s password history Password Expiration Policy The password expiration policy forces expiration of a password after a specified period of time When a user s password expires the user must change the password to complete the authentication process A warning that password expiration is approaching is displayed when the user logs in The n...

Page 583: ... The maximum value must be less than or equal to the minlength value digits value Specifies the minimum number of numeric digits that must occur in the password The default value is 0 The maximum value must be less than or equal to the minlength value punctuation value Specifies the minimum number of punctuation characters that must occur in the password All displayable non alphanumeric punctuatio...

Page 584: ...the admin lockout policy and sets the config parameter passwdcfg adminlockout to 1 If the parameter passwdcfg lockoutthreshold is set to greater than 0 and Admin Lockout policy is enabled then if the number of failed login attempts from the last successful login equals the passwdcfg lockoutthreshold the account gets locked for the passwdcfg lockoutduration duration The particular account is unlock...

Page 585: ...The punctuation value specified must be greater than or equal to 0 and less than or equal to minlength value Total strength specification out of range The total of lowercase value uppercase value digits value and punctuation value must be less than or equal to minlength value History value out of range The history value must be between 1 and 24 Minpasswordage value out of range The minpasswordage ...

Page 586: ... punctuation 0 passwdcfg history 1 passwdcfg minpasswordage 0 passwdcfg maxpasswordage 0 passwdcfg warning 0 passwdcfg lockoutthreshold 0 passwdcfg lockoutduration 30 passwdcfg status 0 To set password configuration parameters specifying that a password must contain at least two uppercase characters and that passwords expire in 90 days from the date they are defined switch admin passwdcfg set uppe...

Page 587: ...g APT policy in effect on the intermediate switches is not a port based policy subsequent data streams may not take the same path as displayed in the pathInfo output Refer to aptPolicy for more information on advanced performance tuning policies If you specify an inactive port or a path through a switch that does not have active routing tables to the destination this command describes the path tha...

Page 588: ...ese statistics this command uses a special pathInfo frame that is sent hop by hop from the source switch to the destination switch To prevent such a frame to loop forever if an error occurs a maximum number of hops for the frame to traverse is enforced The hop count includes all hops in the direct path from source to destination and also all the hops in the reverse path if the tracing of the rever...

Page 589: ...e route to the destination The maximum hop count is enforced in both cases If the source route does not specify all the switches along a section of the path you can specify a strict or a loose path A strict source route requires that only the specified switches are reported in the path description If two switches are specified back to back in the source route descriptor but are not directly connec...

Page 590: ...s The maximum number of hops that the pathInfo frame is allowed to traverse the default is 25 Fabric Id Specifies the Fabric ID If unspecified the value defaults to 1 Default switch FID 128 basic stats Whether basic statistics are generated on every link the default is no extended stats Whether basic statistics are generated on every link the default is no source route Specifies a sequence of swit...

Page 591: ...re provided along with the traceroute option switch admin pathinfo 6 12 13 t Target port is F_Port Hop Domain ID Name Time hop 6 Stealth_I 108186 usec To display basic path information to a specific domain in a Virtual Fabric environment the cost for this hop is the cost of the corresponding path in the base fabric switch admin pathinfo 13 4 Target port is Embedded Hop In Port Domain ID Name Out P...

Page 592: ...0 F s 64s 2743 0 Words 2752748 2822763 Frames 219849 50881 Errors 0 Hop In Port Domain ID Name Out Port BW Cost 1 3 10 web229 12 1G 1000 Port 3 12 Tx Rx Tx Rx B s 1s 36 76 0 0 B s 64s 5 0 Txcrdz 64s 0 0 F s 1s 1 1 0 0 F s 64s 0 0 0 0 Words 240434036 2294316 2119951 2121767 Frames 20025929 54999 162338 56710 Errors 4 0 Hop In Port Domain ID Name Out Pot BW Cost 2 14 8 web228 E output truncated SEE ...

Page 593: ...S Commands and Appendix A Command Availability for details OPERANDS This command has the following optional operand panic_dump_file Specify the full path name of a panic dump file EXAMPLES To examine a panic dump file by the name panic_dump located under the directory tmp switch admin pdshow tmp panic_dump CAUTION Host PLATFORM current is Unknown PLATFORM got from pd file is SW12000 Some results s...

Page 594: ...and the virtual initiator DID and the second monitor would be set up between virtual target SID and the target DID Refer to the Examples section for details Identical monitors cannot be added to the same port Two monitors are considered identical if they have the same SID and DID values after applying the end to end mask Execution of this command displays a monitor number which can be used to mani...

Page 595: ...yptoTarget container configuration This command shows the PIDs for the target the virtual target the initiator and the virtual initiator EncryptionSwitch Securityadmin cryptocfg show container all stat Encryption group name brcd Number of Container s 1 Container name st_target Type disk EE node 10 00 00 05 1e 53 b8 45 EE slot 0 Target 2f ff 00 06 2b 0e b3 3c 2f ff 00 06 2b 0e b3 3c Target PID 0a01...

Page 596: ...ce Shared in Other AD No Redirect No Partial NO N 0a2001 3 20 00 00 05 1e 53 b8 41 20 00 00 05 1e 53 b8 41 na FC4s FCP PortSymb 21 Crypto Virtual Target NodeSymb 58 Cntr Name st_target Tgt Port wwn 2F FF 00 06 2B 0E B3 3C Fabric Port Name 20 20 00 05 1e 53 b8 45 Permanent Port Name 20 00 00 05 1e 53 b8 41 Port Index 32 Share Area No Device Shared in Other AD No Redirect Yes virtual N 0a2002 3 20 0...

Page 597: ...onitor number 1 added 5 Display the EE monitors on the Encryption Switch EncryptionSwitch SecurityAdmin perfmonitorshow class EE 1 There are 2 end to end monitor s defined on port 1 KEY SID DID OWNER_APP TX_COUNT RX_COUNT OWNER_IP_ADDR 0 0x0a0100 0x0a2002 TELNET 0x000000001d914e1c 0x000000002183f0da N A 1 0x0a2001 0x01a000 TELNET 0x0000000002b5c076 0x0000000006c4fb04 N A SEE ALSO perfDelEEMonitor ...

Page 598: ...pported on virtual FC ports VE VEX_Port EX_Port M Mirror ports and GbE ports The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To clear the performance monitoring information from nonvolatile memory switch admin perfcfgclear T...

Page 599: ...NOTES This command requires an Advanced Performance Monitoring license This command is not supported on virtual FC ports VE VEX_Port EX_Port M Mirror ports and GbE ports The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To res...

Page 600: ...monitor count has exceeded limit Some monitors have been discarded NOTES This command requires an Advanced Performance Monitoring license This command is not supported on virtual FC ports VE VEX_Port EX_Port M Mirror ports and GbE ports Monitors created by Web Tools are not saved in persistent memory The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may b...

Page 601: ...Fabric OS Administrator s Guide for specific hardware support OPERANDS This command has the following operands slot For bladed systems only specifies the slot number of the port on which the monitor is to be added followed by a slash port Specifies the number of the port on which the monitor is to be added relative to its slot for bladed systems Use switchShow for a list of valid ports ALPA Specif...

Page 602: ... OPERANDS This command has the following operands slot For bladed systems only specifies the slot number of the port on which to delete the monitor followed by a slash port Specifies the number of the port on which the monitor is to be deleted relative to its slot for bladed systems Use switchShow for a list of valid ports monitorId Specifies the numeric key of the monitor to be deleted The key is...

Page 603: ...estore Restore Performance configuration from FLASH perfcfgsave Save Performance configuration to FLASH perfclearalpacrc Clears the CRC error count associated with a port and Arbitrated Loop Physical Address AL_PA perfcleareemonitor Clears statistics counters of one or more end to end performance monitors perfdeleemonitor Delete end to end monitor perfhelp Print Performance Monitoring help info pe...

Page 604: ... 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands class monitor_class Specifies the monitor class as one of the following EE end to end or ISL interswitch link These values are case sensitive This operand is required slot For bladed systems only specifies the slot number of the port on which the monitor counter is to be cle...

Page 605: ...71 53 1001764 01 perfMonitorClear 22 To clear statistics counters for an ISL monitor switch admin perfmonitorclear class ISL 1 This will clear ISL monitor on port 1 continue yes y no n no y SEE ALSO perfAddEEMonitor perfMonitorShow ...

Page 606: ...formance monitor commands this field displays N A NOTES ISL Monitors are deprecated as of Fabric OS v7 0 0 Management of filter based monitors is no longer supported with this command it is now provided through the Frame Monitor management interface fmMonitor This command requires an Advanced Performance Monitoring license This command is not supported on virtual FC ports VE VEX_Port EX_Port M Mir...

Page 607: ...0000000000000000 N A 4 0xfffff5 0x000005 TELNET 0x0000000000000000 0x0000000000000000 N A 5 0xfffff6 0x000006 TELNET 0x0000000000000000 0x0000000000000000 N A 6 0xfffff7 0x000007 TELNET 0x0000000000000000 0x0000000000000000 N A 7 0xfffff8 0x000008 TELNET 0x0000000000000000 0x0000000000000000 N A 0 0x000000 0x1182ef TELNET 0x0000000000000000 0x0000000000000000 N A To display end to end monitors on ...

Page 608: ...tors the number of monitors currently installed and the remaining available resources In a non Virtual Fabric environment this command displays the resources for the switch NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This comman...

Page 609: ...t 1 2 3 4 5 6 7 8 9 10 11 12 Port 0 1 2 3 4 5 1 6 7 1 8 9 10 11 12 0 13 0 14 15 16 17 18 output truncated To display the number of Top Talkers that can be installed on port 2 37 switch admin perfresourceshow portttRes 2 37 Slot Port Max Installed Available 2 37 4 0 4 To display the number of EE monitors that can be installed on the current logical switch switch admin perfresourceshow eeRes Max Ins...

Page 610: ...ilable Installed 2 0 30 3 To display the status of TT fabric mode on the current logical switch switch admin perfresourceshow fabRes Maximum Installed Available 1 1 0 To display the types of monitors installed on port 2 10 switch admin perfresourceshow installed 2 0 Top Talker Fabric mode Not Installed Top Talker F Port mode Not Installed EE monitor Not Installed Filter monitor Installed ISL monit...

Page 611: ... monitor There is only one EE mask per port The mask is applied to all eight EE monitors available on a port The default EE mask value upon power on is already set When ISL monitoring is enabled the EE mask on E_Ports is controlled automatically and existing mask values for E_Ports are over written NOTES This command requires an Advanced Performance Monitoring license This command is not supported...

Page 612: ...ion marks in dd aa pp format RxDIDMsk Specify the destination ID mask in quotation marks in dd aa pp format EXAMPLES To set the overall mask for end to end monitors on a port switch admin perfsetporteemask 1 6 00 00 00 ff ff ff 00 ff ff ff 00 00 Changing EE mask for this port will cause ALL EE monitors on this port to be deleted continue yes y no n no y The EE mask on port 6 is set and EE Monitors...

Page 613: ...xecution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details This command is not supported on all platforms Refer to the Fabric OS Administrator s Guide for specific hardware support OPERANDS This command has the following operands slot For bladed systems only spec...

Page 614: ...OTES This command requires an Advanced Performance Monitoring license This command is not supported on virtual FC ports VE VEX_Port EX_Port M Mirror ports and GbE ports The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the ...

Page 615: ...Fabric OS Command Reference 581 53 1001764 01 perfShowPortEEMask 22 RxSID Area on RxSID ALPA on RxDID Domain on RxDID Area on RxDID ALPA on SEE ALSO perfAddEEMonitor perfDelEEMonitor perfSetPortEEMask ...

Page 616: ...5000 Top Talker supports the following two modes Port Mode and Fabric Mode In Port Mode Top Talker is installed at the port level to measure the traffic flowing through the port to different destinations The output displays the data in a sorted order based on the data rate of each flow In Fabric Mode Top Talker measures the top n bandwidth using flows on a given switch Top Talker installs only on ...

Page 617: ...s incoming or outgoing This operand is required show Displays the top talking flows on a specified port number of top talking flows Specifies n top talking flows Valid values are between 1 and 32 If a value greater than 32 is entered Top Talker displays counters for only 32 flows and a warning message This operand is optional if omitted the command displays the top 8 flows wwn pid Specifies the ou...

Page 618: ...ys in WWN format delete fabricmode Deletes the Fabric Mode Top Talker EXAMPLES To add an F_Port Top Talker to blade 1 port 2 which should be an F_Port Switch admin perfttmon add ingress 1 2 To delete the F_Port Top Talker switch admin perfttmon del 1 2 To add the Fabric Mode Top Talker Switch admin perfttmon add fabricmode To delete the Fabric Mode Top Talker Switch admin perfttmon del fabricmode ...

Page 619: ... and re created with new parameters A policy cannot be deleted while an active FCIP tunnel is using it NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS The following operands are required option Specifies the action to take Actions i...

Page 620: ... valid only with IKE policies The default is 1 Values include the following 1 Fastest as it uses 768 bit values but least secure 14 Slowest as it uses 2048 bit values but most secure seclife seconds Security association lifetime in seconds A new key is renegotiated before the specified length of time expires The valid range for seconds is 28800 to 250000000 or 0 The default is 28800 EXAMPLES To cr...

Page 621: ...ipsec all IPSec Policy 2 Authentication Algorithm SHA 1 Encryption AES 128 SA Life seconds 28800 IPSec Policy 29 Authentication Algorithm SHA 1 Encryption AES 128 SA Life seconds 28800 Operation Succeeded To change delete and re create a policy switch admin policy ike delete 10 This policy has been successfully deleted switch admin policy ike create 10 enc aes 128 auth sha 1 The following policy h...

Page 622: ...ion to display the port currently bound to a specified port ID PID NOTES This command is supported on the Brocade DCX DCX 4S DCX 8510 8 and DCX 8510 4 on all logical switches including the Default Switch Virtual Fabrics must be enabled It is also supported on the Brocade 300 5100 5300 6510 7800 and VA 40FC regardless of Virtual Fabrics status This command is not supported on embedded platforms If ...

Page 623: ...gned an area Areas are dynamically assigned an address as they are added to a partition The Partition Address Mode value is set by the configure command Enable a 256 Area Limit findPID Displays the port slot and port offset of the port that is currently assigned the provided address This command applies the 10 bit area mask to the provided PID and returns the port that has been assigned the specif...

Page 624: ... 5 20 0x1c00 8 bit 405 5 21 0x1d00 8 bit 406 5 22 0x1e00 8 bit 407 5 23 0x1f00 8 bit 408 5 24 0x1000 8 bit 409 5 25 0x1100 8 bit 410 5 26 0x1200 8 bit 411 5 27 0x1300 8 bit 412 5 28 0x1400 8 bit 413 5 29 0x1500 8 bit 414 5 30 0x1600 8 bit 415 5 31 0x1700 8 bit To display the port address binding for port 28 switch admin portaddress show 5 18 Index Slot Port Area Mode 412 5 28 0x1400 8 bit To displ...

Page 625: ... error NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands slot For bladed systems only specify the slot number of the port to display followed by a slash port Specify the port number to display r...

Page 626: ...t are executed the diagnostic LED pattern is interleaved with the beaconing pattern Running switch beaconing or HBA side E2E beaconing also overwrites the pattern NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the ...

Page 627: ...ric OS Command Reference 593 53 1001764 01 portBeacon 22 To display beaconing mode on a port switch admin chassisbeacon show 2 1 PortBeacon status of slot 2 port 1 is ON SEE ALSO chassisBeacon switchBeacon ...

Page 628: ...command If the port is not configured in long distance mode certain systems might reserve buffers for the port This field then displays the number of buffers reserved for the port Buffer Usage The actual number of buffers allocated to the port In LD mode the number is determined by the actual distance and the user specified desired distance as defined by the desired_distance operand of the portCfg...

Page 629: ...al Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS The following operands are optional slot For bladed systems only specifies the slot number of the port group to display followed by a slash port Specifies the number of a port associated with the port group relative to its slot for bladed ...

Page 630: ...ts depending on the ASIC SID free The total number of free SID CAM entries available for use by this port DID free The total number of free DID CAM entries available for use by this port NOTES This command cannot be executed on a logical port Ports that support shared areas are divided into two ports primary and secondary ports Primary and secondary ports share the same area Port CAM entries displ...

Page 631: ... entries on shared ports in the example port 7 31 and 7 39 are shared ports and 7 31 is the primary port switch user portcamshow 7 39 Area SID used DID used SID entries DID entries 207 3 1 03b380 03cf80 034100 03cf00 SID free DID free 2044 1020 switch admin portcamshow 7 31 Area SID used DID used SID entries DID entries 207 4 2 03b380 03cf80 034100 03cf00 03cf00 03cf80 SID free DID free 2044 1020 ...

Page 632: ...route Configure a static route on the IP interface portcfg vlantag Manage the IP interface VLAN configuration for FCIP Commands supported only on the Brocade 7800 and the Brocade FX8 24 platforms portcfg fciptunnel Create modify and delete Fibre Channel over IP FCIP tunnels although this command is technically valid on the Brocade FR4 18i as well the behavior is very different and the command is t...

Page 633: ...ed followed by a slash port port Specifies a single port or a range of ports for example 3 22 or 1 3 8 port ranges are supported only with the rscnsupr option rscnsupr Manages Registered State Change Notification RSCN suppression on the local port RSCN suppression is configurable only on FC ports The syntax for portCfg rscnsupr is as follows portcfg rscnsupr slot port port mode The following modes...

Page 634: ...e a static route on the IP interface portcfg vlantag Manage the IP interface VLAN configuration for FCIP OPERANDS This command has the following operands slot For bladed systems only specifies the slot number of the port to be configured followed by a slash ge_port Specifies the number of the GbE port to be configured The GbE ports are numbered ge0 ge9 on the Brocade FX8 24 blade and ge0 ge5 on th...

Page 635: ...d on the local XGE port For VE_Ports 12 21 xge1 is the local XGE port and xge0 is the crossport For VE_Ports 22 31 xge0 is the local XGE port and xge1 is the crossport This operand is optional and supported only on the Brocade FX8 24 XGE ports delete ipaddr Deletes IP interfaces Specify the IPv6 or IPv4 address of the virtual port iproute Defines static IP routes on a GbE port or on a 10GbE port A...

Page 636: ... supported only on the Brocade FX8 24 XGE ports delete ipaddr Deletes IP routes for a specified IPv4 or IPv6 address Valid ipaddr values include the following ipaddr Specifies IP address in either IPv6 or IPv4 format IPv6_addr prefix_len Specifies the IPv6 address of the virtual port if IPv6 is used The address must be an IPv6 global unicast address followed by a prefix The prefix_len operand is r...

Page 637: ...lies the VLAN tag to a crossport interface Specifying this parameter allows the VE_Ports 12 21 to use the IP interface with this vlantag This operand is optional and valid only and supported only on the Brocade FX8 24 XGE ports m mgmt Specifying this parameter applies the VLAN tag to the inband management interface EXAMPLES To create an IP interface using IPv4 switch admin portcfg ipif ge0 create ...

Page 638: ...55 255 0 1500 U R M crossport To delete an IP interface switch admin portcfg ipif ge0 delete 192 168 10 20 Operation Succeeded To delete an IP interface for a failover crossport switch admin portcfg ipif 8 xge0 delete 192 168 11 20 x Operation Succeeded To create a static IP route using an IPv4 destination address a netmask and a gateway address switch admin portcfg iproute ge0 create 192 42 0 0 2...

Page 639: ...he same route shows the crossport tag switch admin portshow iproute 8 xge0 Port 8 xge0 IP Address Mask Gateway Metric Flags 2 2 2 0 255 255 255 128 192 168 10 251 0 U G S 2 2 2 0 255 255 255 0 192 168 10 250 0 U G S 192 168 10 0 255 255 255 0 0 U C 192 168 10 250 255 255 255 255 0 U H L 192 168 10 251 255 255 255 255 0 U H L 1 1 1 0 255 255 255 0 192 168 11 250 0 U G S crossport 192 168 11 0 255 2...

Page 640: ... To delete a VLAN tag entry switch admin portcfg vlantag ge2 delete 192 168 2 10 200 Operation Succeeded To delete a VLAN tag entry for a crossport switch admin portcfg vlantag 8 xge0 delete 192 168 11 20 200 x Operation Succeeded FUNCTION Commands supported only on the Brocade 7800 and the Brocade FX8 24 platforms SYNOPSIS portcfg action slot ve_port options arguments DESCRIPTION Use this command...

Page 641: ...p controls VE_Ports 12 21 and the GbE ports ge0 ge9 and the local XGE port xge1 The second FCIP chip controls VE_Ports 22 31 and the local XGE port xge0 Typically that is in the case when you do not configure a failover crossport you use the IP addresses on ge0 ge9 and xge1 for any FCIP circuits that use VE_Ports 12 21 And likewise you use IP addresses on xge0 for any FCIP circuits that use VE_Por...

Page 642: ...sharing of bandwidth between applications The valid range is 10 000 Kbps to 1 000 000 Kbps for 1G ports and 10 000 Kbps to 10 000 000 Kbps for 10G ports The maximum committed rate is the combined maximum committed rate of all configured circuits and it can be no larger than five times the minimum committed rate Both sides of the circuit must have matching configurations Beginning with Fabric OS v7...

Page 643: ...compression on the specified FCIP tunnel By default compression is disabled 0 Specify one of the following values 0 Compression disabled 1 Standard compression 2 Moderate compression 3 Aggressive compression 4 Auto compression Automatically adjusts compression level based on the maximum configured tunnel bandwidth The To enable this feature you must upgrade both ends of the tunnel to Fabric OS v7 ...

Page 644: ...gh 30 medium and 20 low Each priority can have a minimum of 10 the high must be greater than or equal to the medium and the medium must be greater than or equal to the low The sum of percentages must equal 100 Both ends of the tunnel must have the same QoS priority settings and the switches must run Fabric OS v7 0 0 Use the following operands to modify individual settings qos high percentage Speci...

Page 645: ... value will result in poor performance The value should be chosen based upon the typical tape channel program that requires optimum performance The default value is 32 recommended setting The range is 1 to 100 max write pipe value Defines the maximum number of tape write channel commands CCWs that can enter the write pipeline for a single device whether all the CCWs are bundled in a single channel...

Page 646: ... status 0 1 when you modify a circuit C connection type 0 1 2 default listener initiator Specifies whether the circuit is the listener or the initiator Values are 0 Default 1 Listener and 2 Initiator You can use either the numeric values or their string equivalents String values are not case sensitive In default mode the initiator and listener are automatically chosen based on the lower and higher...

Page 647: ...nterface with the portCfg vlantag command The VLAN configuration at the IP interface level is for non data path traffic only If the data path traffic is to be tagged it must be done through the VLAN tagging option with the fcipcircuit create or modify command Note that the circuit VLAN configuration takes priority over the IP interface VLAN configuration The following operands are optional with VL...

Page 648: ...t The following two operands are mutually exclusive comm_rate Specifies the committed traffic rate on the FCIP tunnel in Kbps The valid range is 10 000 Kbps to 1 000 000 Kbps for 1G ports and 10 000 Kbps to 10 000 000 Kbps for 10G ports There is no default Both sides of the tunnel must have matching configurations b min comm rate value B max comm rate value Alternately you can set a minimum and a ...

Page 649: ...the inband management interface The valid range is 1260 to 1500 This operand is optional delete Deletes the specified IP Address for the inband management interface IPv4_address Specifies the IP address to be deleted disable Disables the inband management interface at the specified GbE Port enable Re enables the inband management interface at the specified GbE Port after it has been disabled The i...

Page 650: ...ceeded To create two circuits circuit 0 and circuit 1 on the tunnel these circuits will be created with the FICON compatible keepalive timeout value switch admin portcfg fcipcircuit 1 12 create 0 192 168 51 61 192 168 50 68 b 300000 B 500000 Operation succeeded switch admin portcfg fcipcircuit 1 12 create 1 192 168 50 61 192 168 51 68 b 300000 B 500000 Operation succeeded To display circuit 1 swit...

Page 651: ...reate 1 192 168 2 21 192 168 2 11 2500000 v 200 Operation Succeeded 3 Modify an existing circuit to change the VLAN tag and L2 CoS levels switch admin portcfg fcipcircuit 16 modify 0 v 300 l2cos f 7 l2cos h 5 l2cos m 3 l2cos l 1 WARNING Modify operation can disrupt the traffic on the fcipcircuit specified for a brief period of time This operation will bring the existing circuit down if circuit is ...

Page 652: ... 0x00000000 Circuit ID 16 1 Circuit Num 1 Admin Status Enabled Oper Status In Progress Remote IP 192 168 2 21 Local IP 192 168 2 11 Metric 0 Min Comm Rt 25000000 Max Comm Rt 25000000 SACK On Min Retrans Time 100 Max Retransmits 8 Keepalive Timeout 10000 Path MTU Disc 0 VLAN ID 200 L2CoS F 0 H 0 M 0 L 0 DSCP F 0 H 0 M 0 L 0 Flags 0x00000000 To modify an existing circuit so it becomes the listener s...

Page 653: ...cation Y y N n n y Tunnel 8 12 modify Operation Succeeded To create inband management interfaces for two Brocade 7800 switches on the same subnet 1 Configure each switch switch admin portcfg mgmtif ge0 create 192 168 3 10 255 255 255 0 switch admin portcfg mgmtif ge0 create 192 168 3 20 255 255 255 0 2 Access the switch through the external inband management interface linux telnet 192 168 3 10 To ...

Page 654: ...40 30 0 mgmt Operation Succeeded switch admin portshow vlantag all Port 10 xge0 Interface Address VlanId L2CoS Flags Destination Address 172 16 30 80 30 0 Perm 172 16 50 80 172 16 30 40 30 0 Perm Net Mgmt 0 0 0 0 FUNCTION Commands supported only on the Brocade FR4 18i blade SYNOPSIS portcfg action slot ge_port if_action arguments DESCRIPTION Use this command to manage configuration parameters for ...

Page 655: ... must be specified to delete the entry flush Flushes the ARP table Only dynamic entries can be flushed static entries cannot be cleared fciptunnel Creates modifies or deletes a Fibre Channel over IP FCIP tunnel You can configure up to a maximum of eight FCIP tunnels per GbE port The syntax for portCfg fciptunnel is as follows portcfg fciptunnel slot ge port options arguments optional_arguments The...

Page 656: ...abled t 0 1 Disables 0 or enables 1 read write Tape Pipelining on the existing tunnel requires FCIP FastWrite to be enabled k timeout Specifies the keep alive timeout in seconds Timeout values are 8 to 7 200 The default is 10 If Tape Piplelining is enabled the minimum supported value is 80 M 0 1 Disables 0 or enables 1 default VC QoS mapping on the specified tunnel By default VC QoS mapping is dis...

Page 657: ...n as defined in the IEEE 802 1p specification The range is 0 to 7 The default is 0 ipsec policy _ID Specifies the Internet Protocol security IPSec policy number to be used on the specified tunnel This option must be used together with ike and key ike policy_ID vc_num Specifies the Internet Key Exchange IKE policy number to be used on the specified tunnel This option must be used together with ipse...

Page 658: ...values Supported range is 0 to 7 ficon Use this command to enable or disable FICON emulation in an FCIP tunnel and modify associated parameters on an FCIP tunnel on a VE_Port A feature key is required to enable any of the FICON emulation processing The tunnel must be down or disabled to issue and process the FICON commands The results of this command are persistent The syntax for portCfg ficon is ...

Page 659: ...programs The setting has significance only for host channel initiated operations at this side and does not affect tape write operations initiated by hosts channels attached at the opposite side Too small of a value results in poor performance The value should be chosen based upon the typical tape channel program that requires optimum performance The default value is 32 The range is 1 to 100 b rdMa...

Page 660: ...ed in a single CCW chain If this value is exceeded emulation is suspended The default value is 3 MB 3000000 bytes The range is 1 MB to 5 MB o oxidBase value Defines the base value of an entry pool of 256 OXIDs supplied to emulation generated exchanges It should fall outside the range used by FICO channels and devices to avoid conflicts The default value is 0x1000 The range is 0x0000 to 0xF000 f db...

Page 661: ...Operation Succeeded To create an FCIP tunnel with FastWrite and read write Tape Pipelining enabled switch admin portcfg fciptunnel 3 ge0 create 6 10 1 1 44 192 168 131 124 155000 f t To enable FCIP FastWrite and read write Tape Pipelining on an existing tunnel switch admin portcfg fciptunnel ge1 modify 0 f 1 To create an FCIP tunnel with Byte Streaming enabled switch admin portcfg fciptunnel geo c...

Page 662: ...nd Appendix A Command Availability for details The Fabric OS port configuration commands are not supported on FCoE ports OPERANDS When invoked without operands this command displays the usage The following operands are supported slot For bladed systems only specify the slot number of the port to be configured followed by a slash port Specify the number of the port to be configured relative to its ...

Page 663: ...sruption introduced in some instances of automatic port recovery When the autodisable flag is set you can specify the conditions that will prevent the port to reinitialize Such conditions include loss of sync loss of signal OLS NOS and LIP Refer to the operand section for an explanation of these conditions Note that a link reset does not cause a port autodisable When a port is in FICON Management ...

Page 664: ...on Specify one or more the following options supported with the add remove and addexcept operands LOSN Loss of Sync LOSNG Loss of Signal OLS Offline Primitive Sequence NOS Not Operational Primitive Sequence LIP Loop Initialization Primitive Sequence EXAMPLES To disable the port autodisable feature on single port switch admin portcfgautodisable disable 18 switch admin portcfgautodisable show 18 Por...

Page 665: ...guration for port 18 To enable the port autodisable feature on a range of ports switch admin portcfgautodisable enable 0 2 switch admin portcfgautodisable show 0 2 Port Auto Disable ON Configured Option s No events configured Port will not be automatically disabled Port Auto Disable ON Configured Option s No events configured Port will not be automatically disabled Port Auto Disable ON Configured ...

Page 666: ...o continue If you want to go ahead with the move and the port is configured for encryption or compression you must disable the configuration prior to moving the port You must reconfigure the port on the target switch if you want to use compression or encryption on that port This command is supported only on Condor 3 based platforms running Fabric OS v7 0 0 or later The execution of this command is...

Page 667: ...d switch because port or ports have Encryption Compression enabled Please disable the Encryption Compression configuration FID 15 Slot 0 Port 2 To disable the compression configuration switch admin portcfgcompress disable 2 To attempt to move a configured port to another logical switch SEE ALSO portCfgEncrypt portEncCompShow ...

Page 668: ...ion is enabled NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details The Fabric OS port configuration commands are not supported on FCoE ports OPERANDS This command has the following operands disable Disables credit recovery configuration on the s...

Page 669: ...efault value of 126 on all ports including FCoE ports NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands slot For bladed systems only specifies the slot number of the port to be reset followed by...

Page 670: ...Default 22 QOS Port AE Port Auto Disable OFF Rate Limit OFF F_Port Buffers OFF NPIV PP Limit 126 SEE ALSO portCfgEport portCfgGport portCfgLongDistance portCfgLport portCfgPersistentDisable portCfgPersistentEnable portCfgShow portCfgSpeed portCfgTrunkPort ...

Page 671: ... this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details This command is supported only on Fibre Channel ports SFPs must be 10G or 16G Brocade branded SFPs and run Fabric OS v7 0 0 or later D_Port configuration is not supported on interchassis link ICL ports EX_Ports F_Po...

Page 672: ...es the specified ports as D_Ports disable Clears the D_Port configuration on the specified ports help Displays the command usage EXAMPLES To configure a single port as a D_Port switch admin portdisable 42 switch admin portcfgdport enable 42 switch admin portenable 42 To clear the D_Port configuration switch admin portdisable 42 switch admin portcfgdport disable 42 switch admin portenable 42 SEE AL...

Page 673: ...line or not enabled for encryption Compression configured Displays Yes if compression is enabled on the port Displays No if compression is disabled This parameter is configured with the portCfgCompress command Compression active Displays the port s runtime status Yes indicates that the port is online and enabled for compression No indicates that the port is enabled for compression but offline or n...

Page 674: ...ow 22 151 No No No No 88 No No No No 89 No No No No 90 No No No No 91 No No No No 92 No No No No 93 No No No No 94 No No No No 95 No No No No 208 No No No No 209 No No No No 210 No No No No 211 No No No No 212 No No No No SEE ALSO portCfgEncrypt portCfgCompress ...

Page 675: ...on and for encryption at the same time When you move a configured port to another logical switch you are informed that the operation requires that the port configuration be disabled You are given the choice to cancel the move or to continue If you want to go ahead with the move and the port is configured for encryption or compression you must disable the configuration prior to moving the port You ...

Page 676: ...ld you like to continue y n y Checking for cap port 2 After Checking for cap port 2 val 1 port 2 lscfg The port cannot be moved to the requested switch because port or ports have Encryption Compression enabled Please disable the Encryption Compression configuration FID 15 Slot 0 Port 2 To disable the encryption configuration switch admin portcfgencrypt disable 2 SEE ALSO authUtil portCfgCompress p...

Page 677: ...ot supported on GbE ports and configured F_Port trunks Use the i option without a port index argument to display the portSwap status or alternately use portSwapShow Changes made by this command are persistent across switch reboots or power cycles NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Com...

Page 678: ...Port capability h Displays the command usage EXAMPLES To disable E_Port capability on a port switch admin portcfgeport 1 3 0 To enable E_Port capability on a port switch admin portcfgeport 1 3 1 To lock down the port as an E_Port switch admin portcfgeport 1 3 2 To disable E_Port capability on a range of ports specified by their index number switch admin portcfgeport i 12 18 0 To enable E_Port capa...

Page 679: ...sed by the EX_Port s front phantom domain to request a domain ID from the principal switch The domain ID received becomes the subsequent preferred domain ID which is persistent and is displayed FCR supports FCR connections to McDATA Open Fabric Mode fabrics operating in 239 domain ID mode The 239 DID mode is only supported on the Brocade Mi10k director The portCfgExport command displays the Domain...

Page 680: ...able as EX_Port and enable as non EX_Port portCfgDefault may also be used to disable EX_Ports f fabricid Specifies the fabric ID Valid values are 1 to 128 r ratov Specifies the R_A_TOV used for port negotiation Valid values are 2000 to 120000 This operand is only applicable if the Fabric Parameter attribute value is not Auto Negotiate e edtov Specifies the E_D_TOV used for port negotiation Valid v...

Page 681: ... ID to 4 switch admin portcfgexport 2 0 a 1 f 4 To disable fabric parameter negotiation on port 2 0 of an EX_Port switch admin portcfgexport 2 0 t 2 To enable IDID on port 2 switch admin portcfgexport 2 i 1 To display EX_Port settings configured for Mi10K connectivity switch admin portcfgexport 10 Port 10 info Admin enabled State OK Pid format Not Applicable Operate mode Open Edge Fabric ID 70 Pre...

Page 682: ...e in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details This command is applicable only to Fibre Channel ports OPERANDS This command has the following operands slot For bladed systems only specifies the slot number of the port to be configured followed by a slash port Specifies the number of the port to be configured relative to its slot for bladed sy...

Page 683: ...s of Slot 2 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN Fill Word On Active 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Fill Word Current 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 AL_PA Offset 13 Trunk Port ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON Long Distance VC Link Init Locked L_Port Locked G_Port Disabled E_Port ISL R_RDY Mode RSCN Suppressed Persistent Disabl...

Page 684: ...ic OS Command Reference 53 1001764 01 portCfgFaultDelay 22 FEC Fault Delay 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 where AE QoSAutoEnable AN AutoNegotiate OFF NotApplicable INVALID output truncated SEE ALSO portCfgShow ...

Page 685: ...e In the simplest form of FEC each character is sent twice The receiver checks both instances of each character for adherence to the protocol being used If conformity occurs in both instances the character is accepted If conformity occurs in one instance and not in the other the character that conforms to the protocol is accepted If conformity does not occur in either instance the character is rej...

Page 686: ...capable ON Forward Error Correction configured ON To enable the FEC feature on a port on which this feature is already enabled switch admin portcfgfec enable 18 Same configuration for port 8 To enable the FEC feature on a port range switch admin portcfgfec enable 0 8 To enable the FEC feature on a range of ports some of which were previously enabled the following example enables port 4 switch admi...

Page 687: ...bility for details OPERANDS This command has the following operands slot For bladed systems only specifies the slot number of the port to be configured followed by a slash port Specifies the number of the port to be configured relative to its slot for bladed systems Use switchShow for a listing of valid ports mode Specifies the fill word for the port number This operand is required Valid values ar...

Page 688: ... output truncated To set the fill word of a port to the preferred mode 3 If hardware arb arbff fails try software idle arbff and using the passive option switch admin portcfgfillword 28 aa then ia passive switch admin portcfgshow 28 Area Number 28 Speed Level AUTO HW Fill Word On Active 3 A A then SW I A Fill Word Current 0 Idle Idle output truncated switch admin portcfgshow Ports of Slot 0 16 17 ...

Page 689: ...ails The F_Port buffer feature does not support ports configured as EX_Ports Mirror Ports Long Distance Ports L_Ports QoS Ports Fast Write and Trunk Areas The Fabric OS port configuration commands are not supported on FCoE ports OPERANDS This command has the following operands enable Enables the F_Port buffer configuration on a specified port A port and buffer allocation must be specified with thi...

Page 690: ...h copper ports inactive Both optical SPP ports active Ge0 RJ45 inactive and Ge0 SFP active Ge1 RJ45 inactive and Ge1 SFP active The copper only GbE ports are selected by default To select ge0 or ge1 as optical mode specify the operand as optical Specify copper to re select the default copper port When used with the ge_port operand only this command displays the currently selected GbE port and medi...

Page 691: ...dmin portcfggemediatype ge0 optical To display the current configuration switch admin portcfggemediatype ge0 Port ge1 is configured in optical mode To restore the default configuration copper only ports are selected switch admin portcfggemediatype ge0 copper switch admin portcfggemediatype ge0 Port ge0 is configured in copper mode SEE ALSO portCfgShow ...

Page 692: ...of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands slot For bladed systems only specify the slot number of the port to be configured followed by a slash port Specify the port to be configured relative to its slot fo...

Page 693: ...igured these port configuration parameters are ignored during E_Port initialization Trunk port VC link init The portCfgISLMode and portCfgLongDistance levels LE LD or LS only can be enabled at the same time Such an ISL uses R_RDY mode of flow control over the long distance link This feature is not backward compatible with firmware versions that do not support it NOTES Changes made by portCfgISLMod...

Page 694: ...660 Fabric OS Command Reference 53 1001764 01 portCfgISLMode 22 To disable ISL R_RDY mode on a port switch admin portcfgislmode 1 3 0 SEE ALSO configure portCfgLongDistance portCfgShow ...

Page 695: ...d LS up to 120 km at 10 Gbps and the maximum supported distance can vary greatly depending on switch platform and available buffers Refer to the Fabric OS Administrator s Guide for details on platform specific buffer credit models long distance mode support and maximum distance supported for specific hardware configurations NOTES This command requires an Extended Fabrics license The execution of t...

Page 696: ... total of 1452 full size frame buffers are reserved for data traffic depending on the specified desired_distance value vc_translation_link_init Specifies the fill words used on long distance links When set to 1 the link uses ARB fill words default When set to 0 the link uses IDLE fill words The IDLE fill word option is not compatible with QoS configured links and Credit Recovery enabled links You ...

Page 697: ... Lli 9 Loss_of_sig 9 Proc_rqrd 0 Protocol_err 0 Timed_out 0 Invalid_word 0 Rx_flushed 0 Invalid_crc 0 Tx_unavail 0 Delim_err 0 Free_buffer 0 Address_err 0 Overrun 0 Lr_in 0 Suspended 0 Lr_out 0 Parity_err 0 Ols_in 0 2_parity_err 0 Ols_out 0 CMI_bus_err 0 SEE ALSO configure portCfgISLMode portCfgTrunkPort portCfgShow portShow switchShow ...

Page 698: ...he following operands slot For bladed systems only specifies the slot number of the port to be configured followed by a slash port Specifies the port to be configured relative to its slot for bladed systems Use switchShow to list valid ports mode Specify 1 to enable the configuration Specify 0 to disable the configuration EXAMPLES To enable the configuration on port 1 5 and to display the configur...

Page 699: ...Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS When invoked without operands this command reports the L_Port conditions for all ports present The following operands are supported slot For bladed systems only specify the slot number of the port to be configured followed by a slash port Spe...

Page 700: ...port 22 To display the L_Port conditions switch admin portcfglport Ports of Slot 4 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Locked L_Port ON ON ON Private L_Port Locked Loop HD Loop Fairness output truncated SEE ALSO configure portCfgShow portShow switchShow ...

Page 701: ... from an NPIV device NPIV capable NPIV capability is a switch blade or port attribute that is required for NPIV functionality Some blades within a switch or some ports within a switch or blade may not have NPIV capability NPIV functionality cannot be enabled on such ports and they do not respond to NPIV requests NPIV enabled NPIV functionality must be enabled on a port for it to respond to NPIV re...

Page 702: ...systems Use switchShow for a listing of valid ports enable Enables NPIV on the specified port This command can be executed only in switch mode disable Disables NPIV on the specified port This command can be executed only in switch mode setloginlimit login_limit Sets the maximum number of allowed logins for the specified port This command can be executed both in switch mode and Access Gateway mode ...

Page 703: ...OFF Disabled E_Port OFF Locked E_Port OFF ISL R_RDY Mode OFF RSCN Suppressed OFF Persistent Disable OFF LOS TOV enable OFF NPIV capability OFF QOS E_Port AE Port Auto Disable OFF Rate Limit OFF EX Port OFF Mirror Port OFF Credit Recovery ON F_Port Buffers 12 Fault Delay 0 R_A_TOV NPIV PP Limit 126 CSCTL mode OFF Frame Shooter Port OFF D Port mode OFF To increase the maximum logins on port 1 to 255...

Page 704: ...S TOV enable OFF NPIV capability OFF QOS E_Port AE Port Auto Disable OFF Rate Limit OFF EX Port OFF Mirror Port OFF Credit Recovery ON F_Port Buffers 12 Fault Delay 0 R_A_TOV NPIV PP Limit 255 CSCTL mode OFF Frame Shooter Port OFF D Port mode OFF SEE ALSO configure portCfgDefault portCfgShow ...

Page 705: ...Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following optional operands slot Specifies the slot number followed by a slash on bladed systems port1 port2 Specifies a single port or a range of ports to be configured as N_Ports for example 3 9 or 2 10 15 mode Enables 1 or disables 0 N_Port functionality on the specified ports The de...

Page 706: ... port is running at a speed not supported in the new combo you must disable the port or change the speed to a supported fixed speed before you can set the combo If any of the ports does not meet the conditions the operation fails with an appropriate error message You can change the port speed or disable the ports and retry the command The octet combination default is 1 Use the portCfgOctetSpeedCom...

Page 707: ...ES To configure the ports in first octet for combination 3 on a Brocade 6510 switch admin portcfgoctetspeedcombo 3 3 To reset the combination to default switch admin portcfgoctetspeedcombo 3 default To switch from combo 3 to combo 2 and there are online ports running at 10G speed switch admin portcfgoctetspeedcombo 2 2 The following ports must be disabled or speed configuration needs to be change ...

Page 708: ...ons Use the portCfgPersistentEnable command to enable a port persistently and to restore all previously set port configurations for that port The switch still runs power on diagnostics and initializes a persistently disabled port The portEnable switchEnable and bladeEnable commands do not enable a specific port or ports alone but these commands succeed on a switch with one or more persistently dis...

Page 709: ... persistently switch admin portcfgpersistentdisable 2 12 15 3 10 12 4 3 4 To display the portSwap status switch admin portcfgpersistentdisable i portcfgpersistentdisable portSwap feature enabled i option not supported To disable a port persistently by specifying its index number switch admin portcfgpersistentdisable i 176 To disable a range of ports persistently by specifying the corresponding por...

Page 710: ...istentDisable 22 Disabled YES YES YES YES Slot 0 32 33 34 35 36 37 38 39 Disabled YES YES YES YES YES YES YES YES SEE ALSO ficonCupSet ficonCupShow portCfgDefault portDisable portEnable portCfgPersistentEnable portShow portSwapDisable portSwapShow switchShow ...

Page 711: ... state transition RSCN SNMP trap Web pop up window Persistently enabled ports remain enabled across power cycles switch reboots and switch enables By default a port is enabled persistently unless the port is capable of routing The change in configuration is effectiveimmediately This command re enables all previously set port configurations of a specified port You can temporarily disable a persiste...

Page 712: ... ranges persistently switch admin portcfgpersistentenable 2 24 26 3 10 12 4 3 4 To enable a port persistently by specifying its index number switch admin portcfgpersistentenable i 176 To enable a range of ports persistently by specifying the corresponding port index range switch admin portcfgpersistentenable i 17 18 To enable multiple ports persistently by specifying multiple port index ranges swi...

Page 713: ...e the virtual channel VC so each frame can be prioritized based on the value of the CS_CTL bit CS_CTL flow prioritization is independent of traffic prioritization based on QoS zones and both methods are mutually exclusive If CS_CTL VC mode is enabled on an F FL_Port QoS based traffic flow prioritization cannot be used between any two devices connected to these F FL_Ports in that fabric and vice ve...

Page 714: ...will lose priority to CS_CTL based traffic prioritization resetratelimit Turns off the ingress rate limiting feature on the specified port setratelimit ratelimit Sets an ingress rate limit to reduce traffic from the specified port This configuration is applicable only to F FL_Ports For E EX_Ports this configuration would not be effective The ingress rate limit is enforced only when a given port ca...

Page 715: ...ON ON ON ON ON ON ON ON Long Distance VC Link Init Locked L_Port Locked G_Port Disabled E_Port Locked E_Port ISL R_RDY Mode RSCN Suppressed Persistent Disable LOS TOV enable NPIV capability ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON NPIV PP Limit 126 126 126 126 126 126 126 126 126 126 126 126 126 126 126 126 QOS E_Port AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE EX Port ON ON Mirror Port...

Page 716: ...rms IP interfaces on the GbE port Static routes on the IP interfaces Address resolution protocol ARP entries VLAN tag configuration Fibre Channel over IP FCIP tunnel configuration settings IPSec configuration QoS mappings Brocade FR4 18i only Port mode information Brocade FR4 18i only Displays supported only on the Brocade 7800 FX8 24 platforms Inband Management IP addresses and routes Non GbE por...

Page 717: ... L1 The link is up to 50 km L2 The link is up to 100 km LD The distance is determined dynamically LS The distance is determined statically by user input VC Link Init Displays or OFF when the long distance link initialization option is turned off Displays ON when it is turned on for long distance mode This value is set by the portCfgLongDistance command Locked L_Port Displays ON when the port is lo...

Page 718: ...r Port Displays ON when Mirror Port is enabled on the port Displays or OFF when Mirror Port is disabled This value is set by the portCfg mirrorport command FC Fastwrite Displays ON when FC FastWrite is enabled on the port or or OFF when disabled FastWrite is disabled by default This value is set by the portCfg fastwrite FC Fastwrite is no longer supported as of Fabric OS v7 0 0 Rate Limit Displays...

Page 719: ...tCfgShow is issued for a single FCoE port only the following fields are displayed Area Number Speed Level AL_PA Offset RSCN Suppressed and NPIV PP Limit If the command is issued without operands on a DCX with one or more FCOE10 24 blades the port parameters that are not valid on the FCoE ports are marked with a dash Refer to the example section for an illustration You can identify a single port to...

Page 720: ... tunnels and parameters not applicable to these platforms are not displayed Use the portShow command to display FCIP tunnel and circuit parameters on the Brocade 7800 FX8 24 ipif Displays the IP interface for both ports of the tunnel IPv6 addresses are supported iproute Displays the IP route on the specified GbE port IPv6 addresses are supported arp Displays the address resolution protocol ARP tab...

Page 721: ... The display includes the interface status enabled or disabled the interface IPv4 Address the netmask effective MTU and annotated port flags mgmtroute ge_port Displays the management routes configured for a specified GbE Port The display includes the destination IPv4 Address the netmask the gateway address and annotated port flags The metric field is not valid for the Brocade 7800 EXAMPLES To disp...

Page 722: ...Disable CSCTL mode D Port mode Fault Delay 0 0 1 where AE QoSAutoEnable AN AutoNegotiate OFF NotApplicable INVALID To display the port configuration settings for all ports on slot 1 on a Brocade DCX 8510 4 switch admin portcfgshow slot 1 Index 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Octet Speed Combo 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AL_PA Offset 1...

Page 723: ... LOS TOV enable NPIV capability ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON NPIV PP Limit 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 QOS E_Port AE AE AE AE AE AE AE AE AE AE AE AE EX Port Mirror Port Rate Limit Credit Recovery ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON Fport Buffers Port Auto Disable CSCTL mode D Port mode Compression Encryption FEC ON ON ON ON ON ON ON ON ON ON ON O...

Page 724: ..._Port truncated Locked E_Port truncated ISL R_RDY Mode truncated RSCN Suppressed truncated Persistent Disable truncated LOS TOV enable truncated NPIV capability truncated NPIV PP Limit 126 126 126 126 126 126 126 126 truncated QOS E_Port truncated Fport Buffers truncated Port Auto Disable truncated output truncated To display port configuration settings for a single FCoE port on a DCX with a Broca...

Page 725: ...ayed parameters switch admin portcfgshow 12 ge0 Mode FCIP Persistent Disable OFF Ipif configuration Interface IP Address NetMask MTU 0 192 168 100 50 255 255 255 0 1500 1 192 168 100 51 255 255 255 0 1500 2 192 168 100 52 255 255 255 0 1500 3 192 168 100 53 255 255 255 0 1500 4 192 168 100 54 255 255 255 0 1500 5 192 168 100 55 255 255 255 0 1500 6 192 168 100 56 255 255 255 0 1500 7 192 168 100 5...

Page 726: ...68 78 Compression off Fastwrite off Tape Pipelining off Committed Rate 100000 Kbps 0 100000 Gbps SACK on Min Retransmit Time 100 Keepalive Timeout 10 Max Retransmissions 8 VC QoS Mapping off DSCP Control 0 DSCP Data 0 VLAN Tagging Not Configured VC QoS Map default VC DSCP L2CoS VC DSCP L2CoS VC DSCP L2CoS VC DSCP L2CoS 0 46 7 1 07 0 2 11 3 3 15 3 4 19 3 5 23 3 6 27 0 7 31 0 8 35 0 9 39 0 10 43 4 1...

Page 727: ...guration Interface Address VlanId L2CoS Destination Address 192 168 2 10 200 5 0 0 0 0 192 168 2 10 300 5 192 168 2 21 To display the VLAN tagging configuration only switch admin portcfgshow vlantag ge2 Port ge2 Vlantag configuration Interface Address VlanId L2CoS Destination Address 192 168 2 20 200 5 0 0 0 0 192 168 2 21 300 5 192 168 2 10 To display an FCIP Tunnel on a Brocade FX8 24 with and w...

Page 728: ...gle GbE Port on a Brocade 7800 switch admin portcfgshow mgmtif ge0 Inband Management ge0 Enabled Interface IPv4 Address NetMask Effective MTU Flags 0 20 20 0 151 255 255 255 0 1500 Flags U Up B Broadcast D Debug L Loopback P Point2Point R Running N NoArp PR Promisc M Multicast S StaticArp LU LinkUp To display the management route for a configured inband management interface on a Brocade 7800 switc...

Page 729: ...e configured by its port number or by its port index number Port ranges are supported with index numbers or by specifying a slot or a slot range Use switchShow for a listing of valid ports slots and port index numbers Specifying multiple ports with the index i or slot s option is supported only if PortSwap is disabled They are not supported on GbE ports and configured F_Port trunks Use the i optio...

Page 730: ...n 10G and 16G platforms 2 The port is set at a fixed speed of 2 Gbps 4 The port is set at a fixed speed of 4 Gbps 8 The port is set at a fixed speed of 8 Gbps 10 The port is set at a fixed speed of 10 Gbps not supported on 8G platforms 16 The port is set at a fixed speed of 16 Gbps not supported on 8G platforms h Displays the command usage EXAMPLES To set the speed of a port to 10 Gbps switch admi...

Page 731: ...g Fabric OS Commands and Appendix A Command Availability for details The Fabric OS port configuration commands are not supported on FCoE ports Virtual FC Ports do not support frame based trunking If trunking is enabled for one of these ports in a slot and a Brocade FX8 24 Extension blade is inserted into the slot the configuration is not honored and the system logs a RASLOG error An attempt to ena...

Page 732: ...ent for every edge fabric If two ports are connected to the same fabric but have been assigned different fabric IDs one of them will be disabled due to a fabric ID oversubscription If two fabrics have been assigned the same fabric ID one of them will be disabled due to a fabric ID conflict The front domain WWN field displays the WWN of the front domain If the port is enabled and the state is OK th...

Page 733: ...o 239 For McDATA Fabric mode m 2 valid values are 1 to 31 p pidformat Specifies the Port ID format Valid values are 0 native 1 core 2 extended edge This operand is applicable only when port mode is set to 0 native mode If port mode is not Brocade Native the Port ID format displays as Not applicable t fabric_parameter Enables or disables negotiation of the fabric parameters Valid values are 1 enabl...

Page 734: ...fabric s version stamp N A To set the fabric ID of port 2 21 to 5 and the port ID format to core switch admin portcfgvexport 2 21 f 5 p 1 To configure port 2 20 as a VEX_Port and set the fabric ID to 4 switch admin portcfgvexport 2 20 a 1 f 4 To disable fabric parameter negotiation on port 2 20 of a VEX_Port switch admin portcfgvexport 2 20 t 2 SEE ALSO portCfgEXPort portDisable portEnable portSho...

Page 735: ...ng or trace a route to a destination IP host from an intelligent GbE port or to determine the path characteristics between a local data source and a remote data sink The following portCmd features are platform specific IPperf Supported only on the Brocade FR4 18i Tperf Supported only on the Brocade 7800 FX8 24 VLAN tagging Supported on the Brocade 7800 FX8 24 and FR4 18i IPv6 Supported on the Broc...

Page 736: ...r datagram that can be transmitted over the end to end path without fragmentation This value is measured in bytes and includes the IP header and payload There is limited support for black hole PMTU detection PTMUs of decreasing size are sent Jumbo PMTU greater than 1500 bytes 1500 bytes and 1260 bytes the minimum PMTU supported for FCIP tunnels If the 1260 PMTU transmission fails the ipperf comman...

Page 737: ...onds If the duration is greater than t running_time the statistics displays only once at the conclusion of the test This operand is optional p port Specifies the TCP port number for the listener end point This operand is optional q diffserv Specifies the DSCP DiffServ Code Point marking used for the TCP connection This operand accepts values between 0 and 63 The default value is 0 This operand is ...

Page 738: ...ies the number of ping requests Valid values are 1 to 255 The default is 4 This operand is optional q service_type Specifies the type of service in the ping request The default is 0 and service_type must be an integer from 0 to 255 This operand is optional t ttl Specifies the time to live Valid values are 1 to 255 The default is 100 This operand is optional w wait_time Specifies the time to wait f...

Page 739: ... the time in milliseconds to wait for a response to a probe The default is 5000 milliseconds The maximum wait time is 9000 milliseconds 9 seconds This operand is optional z size Specifies the size in bytes of the trace route packet to use The default is 64 bytes In an IPv4 environment the ICMP IP header occupies 28 bytes In an IPv6 environment it occupies 48 bytes The total size including ICMP IP ...

Page 740: ...ata sink has been started on the opposing switch before the data source is started on the local switch The following arguments are optional high Generates high priority traffic medium Generates medium priority traffic low Generates low priority traffic If no traffic priority is specified only medium priority traffic is generated time duration Specifies the duration of the TPerf traffic flow in sec...

Page 741: ...0 60 bytes 64 rtt 0ms ttl 255 Reply from 2007 7 30 32 227 77 0 60 bytes 64 rtt 0ms ttl 255 Ping Statistics for 2007 7 30 32 227 77 0 60 Packets Sent 4 Received 4 Loss 0 0 percent loss Min RTT 0ms Max RTT 1ms Average 0ms To trace the IP router hops used to reach the remote with packet size specified switch admin portcmd traceroute 12 ge0 s 2007 7 30 32 227 138 10 120 d 2007 7 30 32 227 77 0 60 z 14...

Page 742: ...e sink switch admin portcmd tperf 16 source size 2048 pattern 5 TPerf has been configured successfully for 16 TPerf is generating traffic on 16 priority medium Tunnel ID 16 High Priority Medium Priority Low Priority bytes tx 0 5280520 0 bytes rx 0 407240 0 PDUs tx 0 10183 0 PDUs rx 0 10182 0 out of seq PDUs rx 0 0 0 flow control count 0 0 0 last rtt 0 5 0 To configure a TPerf source so it generate...

Page 743: ...or 16 TPerf is generating traffic on 16 priority low Tunnel ID 16 High Priority Medium Priority Low Priority bytes tx 0 0 19800708 bytes rx 0 0 0 PDUs tx 0 0 1434686 PDUs rx 0 0 0 out of seq PDUs rx 0 0 0 flow control count 0 0 0 last rtt N A N A N A To specify test data patterns for the source payload switch admin portcmd tperf 16 source pattern random switch admin portcmd tperf 16 source pattern...

Page 744: ...ect to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands dbg_lvl Specify the debug level to be set for port modules valid values are 1 to 5 vbs_lvl Specify the verbose level to be set for port modules valid values are 1 to 5 EXAMPLES To set deb...

Page 745: ...e remote switch on the other end of the E_Port This command will fail for online ports if the port is not a fully operational E_Port or trunk port lossless is not enabled on the local or remote switch or no alternate redundant path is available to route the traffic A redundant path must be an E_Port connection between the same pair of switches as the E_Port that is being decommissioned Use the top...

Page 746: ...cycle If the port was online before being disabled a state transition will be indicated in one of the following ways RSCN SNMP trap or Web pop up window NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details This command is not supported on FCoE po...

Page 747: ...switch admin portdisable i 176 To disable a range of ports by specifying the corresponding port index range switch admin portdisable i 170 176 To disable multiple ports by specifying multiple port index ranges switch admin portdisable i 30 36 170 176 To disable all ports on slots 3 5 switch admin portdisable s 3 5 To disable all ports on slots 3 5 and 9 12 switch admin portdisable s 3 5 9 12 SEE A...

Page 748: ...ecified ports at any time during the test or after the diagnostics has completed The command output includes the following information for each configured D_Port Port The port number on the local side of the link Remote WWN The world wide node name of the switch on the remote side of the link Remote Port The port number on the remote side of the link Start time Date and time of test start End time...

Page 749: ...ed only on Fibre Channel ports SFP s must be Brocade branded and run Fabric OS v7 0 0 or later OPERANDS This command has the following operands slot On bladed systems only specifies the slot number of the ports to be configured followed by a slash port_list Specifies one or more ports relative to the slot on bladed systems Use switchShow for a listing of valid ports A port list should be enclosed ...

Page 750: ...0 05 33 13 2f b4 Remote port 26 Mode Automatic Start time Wed Feb 2 01 41 35 2011 End time Wed Feb 2 01 43 23 2011 Status PASSED Test Start time Result EST secs Comments Electrical loopback 01 42 12 PASSED Optical loopback 01 43 10 PASSED Link traffic test 01 43 17 PASSED Roundtrip link latency 1108 nano seconds Estimated cable distance 20 meters To display D_Port summary information switch admin ...

Page 751: ...the following indications might be sent to indicate a state transition RSCN SNMP trap Web pop up window This command fails if the switch is disabled the port s blade is not fully enabled faulted powered off or disabled or if the port is persistently disabled NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using F...

Page 752: ...rtenable i 176 portenable portSwap feature enabled To enable a range of ports by specifying the corresponding port index range switch admin portenable i 170 176 portenable portSwap feature enabled To enable multiple ports by specifying multiple port index ranges switch admin portenable i 30 36 170 176 portenable portSwap feature enabled To enable all ports on slot 3 5 switch admin portenable s 3 5...

Page 753: ...shorter than minimum received Rx too long Number of frames longer than maximum received Rx bad eof Number of frames with bad end of frame delimiters received Rx enc out Number of encoding error outside of frames received Rx disc c3 Number of Class 3 frames discarded Rx This counter includes the sum of the following class 3 discard counters reported by the portStatsShow command er_rx_c3_timeout er_...

Page 754: ...Fabric OS Commands and Appendix A Command Availability for details This command is not supported on FCoE ports OPERANDS None EXAMPLES To display error counters for ports on a switch switch admin porterrshow frames enc crc crc too too bad enc tx rx in err g_eof shrt long eof out 0 0 0 0 0 0 0 0 0 0 1 2 5g 73m 0 0 0 0 0 0 1 2k 2 0 0 0 0 0 0 0 0 0 3 0 0 0 0 0 0 0 0 667 disc link loss loss frjt fbsy c...

Page 755: ...default Port fencing monitors ports for erratic behavior and disables a port if specified error conditions are met The portFencing command enables and configures the port fencing feature it does not set the thresholds for port fencing You must configure port thresholds with the portThConfig command before you can enable port fencing NOTES The execution of this command is subject to Virtual Fabric ...

Page 756: ...ecifies one or more Fabric Watch areas to be monitored by the port fencing feature Areas are not case sensitive Alternately use the all option to specify all of the following areas CRC Cyclic redundancy check error ITW Invalid word transmission PE Protocol error ST State Change LR Link reset C3TX_TO Class 3 frame discard due to timeout help Displays the command usage EXAMPLES To enable port fencin...

Page 757: ...switch admin portFencing show Port Type Area PF Status E port CRC disabled ITW enabled LR enabled PE enabled ST enabled FOP port CRC enabled ITW enabled LR enabled C3TX_TO enabled PE enabled ST enabled Port CRC enabled ITW disabled LR disabled C3TX_TO disabled PE disabled ST disabled SEE ALSO fwHelp portThConfig ...

Page 758: ...for all ports in the switch switch user portflagsshow Port SNMP Physical Flags 0 Online In_Sync PRESENT ACTIVE F_PORT G_PORT U_PORT LOGICAL_ONLINE LOGIN NOELP ACCEPT FLOGI 1 Online In_Sync PRESENT ACTIVE E_PORT G_PORT U_PORT SEGMENTED CBL_LB LOGIN LED 2 Offline No_Module PRESENT U_PORT LED 3 Offline No_Light PRESENT U_PORT LED 4 Offline No_Module PRESENT U_PORT LED 5 Offline No_Module PRESENT U_PO...

Page 759: ...SigDet PRESENT U_PORT LED 6 17 Offline No_SigDet PRESENT U_PORT LED 6 18 Offline No_SigDet PRESENT U_PORT LED 6 19 Offline No_SigDet PRESENT U_PORT LED To display the port status for QSFPs installed and connected with cables partial output 6 28 Online In_Sync PRESENT ACTIVE E_PORT T_PORT T_MASTER G_PORT U_PORT LOGICAL_ONLINE LOGIN LED 6 29 Online In_Sync PRESENT ACTIVE E_PORT T_PORT T_MASTER G_POR...

Page 760: ... the command completes the ATTN LEDs flash amber indicating that the command has finished and exited Enable the current switch using the switchEnable command to set the ATTN LEDs back to black NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details ...

Page 761: ...To test port LEDs switch admin portledtest slot 1 ports 1 1 1 5 Running portledtest WARNING This test should NOT be aborted in the middle If aborted current blade or the switch in case of Pizza box may become unusable Reset the blade or the switch to recover PASSED To test port LEDs on a Brocade 8000 using default values switch admin ceeportledtest PASSED SEE ALSO fcipLedTest itemList switchDisabl...

Page 762: ... to understand the cause of the error When the port log is disabled the events already present in the log are preserved but new events are not collected The following errors disable the port log FCPH EXCHBAD FCPH EXCHFREE NBFSM DUPEPORTSCN UCAST RELICPDB Refer to the Fabric OS Message Reference for more information on these errors NOTES The execution of this command is subject to Virtual Fabric or...

Page 763: ...lay the current port log configuration NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To display the current port log configuration switch admin portlogconfigshow max portlog entries 16384 SEE ALSO portLogResize ...

Page 764: ... command to disable the port log facility NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To display the port log facility switch admin portlogdisable SEE ALSO portLogEnable ...

Page 765: ...ayed This operand is optional saved Specify a nonzero value to display the saved port log from the last switch fault Refer to upTime for conditions that cause a fault The operand count is ignored when displaying the saved log This operand is optional EXAMPLES To display 10lines of the portlog on a Brocade DCX switch user portlogdump 10 time task event port cmd args Mon Nov 16 21 52 15 2009 21 52 1...

Page 766: ...layed Refer to portLogClear command for more information NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operand port_index Displays the port log for the a single port specified by its port index numbe...

Page 767: ...command to enable the port log facility NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To enable the port log facility switch admin portlogenable SEE ALSO portLogDisable ...

Page 768: ...ect to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To display information about port log events switch admin portlogeventshow ID Event Name Disabled 1 start 0 2 disable 0 3 enable 0 4 ioctl 0 5 Tx 0 6 Tx1 0 7 Tx2 0 8 Tx3 0 9 Rx 0 10 Rx1 0 11 Rx2 0 12 Rx3 0 13 stat...

Page 769: ...Flogs and EE end to end credit for PLOGIs df_sz The default frame size for this login cos Class of Services supported This can be a combination of the following bits 4 Class 2 is supported 8 Class 3 is supported Further information about each login is displayed after these columns including the Port ID of the well known address or N_Port that was the target of the PLOGI if applicable NOTES The exe...

Page 770: ... Port 23 revealing one FLOGI type fe and two PLOGIs switch admin portloginshow 23 Type PID World Wide Name credit df_sz cos fe 201700 21 00 00 e0 8b 05 a3 c9 3 2048 8 scr 1 ff 201700 21 00 00 e0 8b 05 a3 c9 0 0 8 d_id FFFC20 ff 201700 21 00 00 e0 8b 05 a3 c9 0 0 8 d_id FFFFFC SEE ALSO fcpProbeShow portShow ...

Page 771: ...Port Discovery parameters The PDISC log is disabled by default NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operand 0 1 Specify 0 to clear or 1 to set the debug_pdisc_flag The default is 0 EXAMPLES ...

Page 772: ...log facility NOTES Refer to portLogClear for events that may disable the port log facility The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To enable the port log switch admin portlogreset SEE ALSO None ...

Page 773: ...s no change NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operand num_entries Specifies the number of port log entries The valid range of values is 32 768 to 13 1072 for the Brocade Encryption Switch...

Page 774: ...ile the port log is disabled a warning message is displayed Refer to the portLogClear command for more information For each log entry the following information is displayed Time Displays the event date and time in milliseconds The clock resolution is 16 milliseconds Task Displays the name of the task that logged the event or interrupt if the event was logged in interrupt context or unknown if the ...

Page 775: ...Indicates an information unit header log from a read operation write Inidcates an information unit header log from a write operation err Indicates an information unit header log of an FC error frame frame Indicates a Fibre Channel frame payload nsRemQ Indicates an interswitch name server query rscn Indicates a Registered State Change Notification xalloc Allocates an exchange xfree Frees an exchang...

Page 776: ... Offline disconnected or nonparticipating LIP FL_Port entered INITIALIZING or OPEN_INIT state LIM LISM completed FL_Port became the loop master BMP Loop init completed FL_Port in MONITORING state OLD Port transitioned to the OLD_PORT state TMO Loop init times out Args Displays additional information about the event as follows start Start type 0 enable ports 100 disable ports disable State refer to...

Page 777: ...ment 1 and 2 represents the first and second words of the CT payload if applicable as specified in A If B is a reject argument 1 contains the CT reject reason and explanation code errlog Error type refer to errShow loopscn The meaning further depends on each loop state OLP Offline reason code usually zero LIP Reason code for LIPs initiated by FL_Port if the code value is 800x x 1 0xc see below or ...

Page 778: ...LF2 Link Failure NOS Receive State OL1 Offline OLS Transmit State OL2 Offline OLS Receive State OL3 Offline Wait for OLS State LIP reason Valid LIP reason codes include the following 8001 Retry loop init 8002 Start loop after gaining sync 8003 Restart loop after port reset 8004 LIP when a loop hangs 8005 Restart loop if LIP received when sending out ARB F0 8006 LIP when an OPN returns 8007 Restart...

Page 779: ... To view the port log for a port switch user portlogshow 24 time task event port cmd args 17 05 30 384 PORT Rx 0 40 02fffffd 00fffffd 08fbffff 14000000 17 05 30 384 PORT Tx 0 0 c0fffffd 00fffffd 08fb0e02 17 05 30 384 PORT debug 0 00c0ffee 00fd0118 00000000 00000001 17 05 30 389 PORT Rx 1 40 02fffffd 00fffffd 08fdffff 14000000 17 05 30 389 PORT Tx 1 0 c0fffffd 00fffffd 08fd0e03 17 05 30 389 PORT de...

Page 780: ...05 31 775 PORT debug 2 00c0ffee 00fd015c 14000000 00000001 17 05 31 777 PORT Rx 2 0 c0fffffd 00fffffd 0e080907 17 05 31 778 PORT Tx 3 40 02fffffd 00fffffd 0e09ffff 14000000 17 05 31 779 PORT debug 3 00c0ffee 00fd015e 14000000 00000001 17 05 31 782 PORT Rx 3 0 c0fffffd 00fffffd 0e090908 SEE ALSO portLogClear portLogDump upTime ...

Page 781: ...ANDS This command has the following operands port_index Displays the port log for a single port specified by its port index number Use switchShow for a listing of valid port index numbers EXAMPLES To display the port log for port 14 switch user portlogshowport 14 time task event port cmd args 08 35 28 483 tFabric scn 14 0 08 35 27 899 tShell pstate 14 OL1 08 35 27 899 tReceive pstate 14 LR2 08 35 ...

Page 782: ...bric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operand id Specifies a nonzero value that corresponds to the port log type to be disabled Use portLogEventShow for a listing of values corresponding to supported log types EXAMPLES To disable logging of type 2 por...

Page 783: ...Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operand id Specifies a nonzero value that corresponds to the port log type to be enabled Use portLogEventShow for a listing of values corresponding to supported log types EXAMPLES To enable logging of ty...

Page 784: ...ber cable Only one frame is transmitted and received at any given time An external cable is not required to run this test The port LEDs flicker green rapidly while the test is running The test performs the following operations 1 Sets all ports for parallel loopback 2 Creates a frame F of maximum data size 2 112 bytes 3 Transmits the frame F through port N 4 Picks up the frame from the same port N ...

Page 785: ...s OPERANDS This command has the following operands slot slot Specifies the number of the slot on which to run the diagnostics All eligible ports relative to the slot number are tested The default is 0 and designed to operate on fixed port count products nframes count Specifies the number of frames to send The test progresses until the specified number of frames has been transmitted on each port Th...

Page 786: ...he following error messages If errors persist contact Technical Support DATA Data received does not match the data sent ERRSTAT Errors were found in the ASIC statistics INIT Port failed to initialize PORTDIED A previously initialized port went to an uninitialized state STATS Errors were found in the ASIC statistics TIMEOUT Did not receive a frame in the given timeout period XMIT Frame transmission...

Page 787: ... port reside in the same switch standalone platform SID DID and mirror port reside in different blades in the same chassis SID DID and mirror port reside in two different chassis or standalone switches connected through interchassis or interswitch links The DID can be either on the local switch or on a different switch Any given SID can participate in either one or a maximum of three mirror connec...

Page 788: ...ervice The Brocade 300 5300 and most embedded switches can participate only in one mirror connection All other platforms support up to three mirror connections These limitations hold regardless of whether Virtual Fabrics are enabled or disabled When in order deliver IOD is enabled deleting a mirror connection can cause frame loss between the SID and DID If IOD is disabled deleting a mirror connect...

Page 789: ...LOS TOV enable OFF NPIV capability ON QOS E_Port AE Port Auto Disable OFF Rate Limit OFF EX Port OFF Mirror Port ON output truncated switch admin switchshow grep Online switchState Online 1 1 640100 id N2 Online FC G Port 2 2 640200 id N2 Online FC E Port 10 00 00 05 1e 36 01 26 sw0 downstream 7 7 640700 id N4 Online FC F Port 20 14 00 05 1e a2 f9 b1 8 8 640800 id N2 Online FC F Port 1 N Port 2 NP...

Page 790: ... 0x640700 0x640c00 Enabled To delete a port mirror connection between two local switch ports switch admin portmirror delete 0x640700 0x640c00 To add a port mirror connection between a local switch port and a remote switch port switch admin portmirror add 2 1 0x011400 0x240400 To delete a port mirror connection between a local switch port and a remote switch port switch admin portmirror delete 0x01...

Page 791: ...ecifying multiple ports with the index i or slot s option is supported only if PortSwap is disabled They are not supported on GbE ports and configured F_Port trunks Use the i option without a port index argument to display the portSwap status or alternately use the portSwapShow command Like all other configurable port attributes port names persists across reboots and power cycles They are not affe...

Page 792: ...bash shell for example enter a single quotation mark as enter an exclamation mark as or enter a pipe as h Displays the command usage EXAMPLES To name a port tape drive 8 switch admin portname 1 3 n Tape drive 8 switch admin portname 1 3 Tape drive 8 To assign a name to a range of ports specified by port index numbers switch admin portname i 22 26 n backup switch admin portname i 22 26 port 22 back...

Page 793: ...er 1 Using Fabric OS Commands and Appendix A Command Availability for details When FastWrite or Tape Pipelining is enabled the portPerfShow VE link output is different The acceleration entity FastWrite or Tape Piplelining responds by sending XFER_RDY and status well ahead of the actual device s response to the host The host sends data which is stored near the device and is delivered to the device ...

Page 794: ...24 25 26 27 28 29 30 31 0 210 1m 840 6m 210 1m 0 0 0 0 0 0 0 0 0 0 0 0 32 33 34 35 36 37 38 39 Total 0 0 0 0 0 0 0 0 2 5g output stopped To display port performance for all ports with an interval of 5 seconds switch user portperfshow t 5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 630 4m 0 0 0 0 0 0 0 0 112 630 4m 0 0 0 0 0 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 0 210 1m 840 6m 210 1m 0 112 0 0...

Page 795: ... 0 tx t 5 0 210 1m 0 210 1m output truncated To display receiver throughput for a single port at a 5 second interval switch user portperfshow 0 rx t 5 0 420 3m 0 420 2m output truncated To display port performance on a chassis for range of ports at an interval of 5 seconds switch user portperfshow 12 0 12 6 t 5 0 1 2 3 4 5 6 Total slot 12 840 6m 0 0 0 0 0 630 4m 1 4g 0 1 2 3 4 5 6 Total slot 12 84...

Page 796: ... routing table Displays how the specified port forwards unicast frames to a locally attached NX_Port in the following format area_number ports_bitmap area_number The area number of a device or set of looped devices attached to the local switch ports_bitmap The format of ports_bitmap is the same as the one used in the external unicast routing table Broadcast routing table Displays how the specified...

Page 797: ...ing tables for a port switch user portrouteshow 4 15 port address ID 0x02bf00 external unicast routing table 1 0x4 vc 3 2 0x10000 vc 0 internal unicast routing table 60 0x8000 vc 2 63 0x1000 vc 5 broadcast routing table 0x10000 SEE ALSO bcastShow fabricShow switchShow topologyShow uRouteShow ...

Page 798: ... platform on which they are executed Platform specific commands are documented in separate sections that include function synopsis description operands and examples Use the following section headings to navigate this page General port status display commands supported on all platforms Port display commands supported only on the Brocade 7800 FX8 24 and on the Brocade FR4 18i platforms portshow ipif...

Page 799: ... assigned to the port portName Name assigned to the port by the portName command On standalone platforms the default port name is the port number for example port5 On enterprise class platforms the default port name is a combination of the slot number and the port number for example slot1port5 portHealth Current health of the port requires a Fabric Watch license Authentication Authentication type ...

Page 800: ...face card present No_Module No module GBIC or other present No_Light Module is not receiving light Condor 2 ports only No_SigDet No signal detected displays when a quad small form factor pluggables QSFPs is installed without cables Mod_Inv Incompatible vendor or module speed mismatch No_Sync Receiving light but out of sync In_Sync Receiving light and in sync Laser_Flt Module is signaling a laser f...

Page 801: ...f the port is configured as an EX_Port the following additional port information is displayed EX_Port Mode The port is configured as an EX_Port Fabric ID The fabric ID assigned to this EX_Port this is the fabric ID of the edge fabric attached to this EX_Port Front Phantom Information on the front phantom domain presented by this EX_Port Includes the preferred if not active or actual if active doma...

Page 802: ...oginshow to display FCoE specific configuration details Following the general information the command displays three columns of counters The first column shows interrupt statistics Interrupts Total number of interrupts Unknown Interrupts that are not counted elsewhere Lli Low level interface physical state primitive sequences Proc_rqrd Frames delivered for embedded N_Port processing Timed_out Fram...

Page 803: ...portSwapShow EXAMPLES To display the current state of a D_Port switch admin portshow 28 portName port28 portHealth No Fabric Watch License Authentication None portDisableReason None portCFlags 0x1 portFlags 0x10004103 PRESENT ACTIVE E_PORT G_PORT D_PORT U_PORT LOGIN LED LocalSwcFlags 0x0 portType 24 0 POD Port Port is licensed portState 1 Online Protocol FC portPhys 6 In_Sync portScn 0 Flow contro...

Page 804: ...he state of a VE_Port on a chassis with an FX8 24 blade switch admin portshow 7 12 portIndex 140 portName slot7port12 portHealth No Fabric Watch License Authentication None portDisableReason None portCFlags 0x1 portFlags 0x490b PRESENT ACTIVE VIRTUAL E_PORT G_PORT U_PORT LOGICAL_ONLINE LOGIN LED portType 12 0 portState 1 Online Protocol FC portPhys 255 N A portScn 16 E_Port port generation number ...

Page 805: ...ic s primary wwn N A Edge fabric s version stamp N A portDisableReason None portCFlags 0x1 portFlags 0x903 PRESENT ACTIVE G_PORT U_PORT EX_PORT LOGICAL_ONLINE LOGIN portType 10 0 portState 1 Online portPhys 6 In_Sync portScn 1 Online Trunk master port port generation number 160 portId 965400 portIfId 43820005 portWwn 20 54 00 05 1e 36 0e e0 portWwn of device s connected Distance normal portSpeed N...

Page 806: ...play FCIP related configuration parameters on the Brocade 7800 FX8 24 and on the Brocade FR4 18i blade The parameters displayed by this command are set with the portCfg command The following displays are supported with this command portshow ipif Displays the local IP interfaces portshow iproute Displays static routes on the IP interface portshow arp Displays the content of the address resolution p...

Page 807: ...r each entry the output displays the IP interface address the destination IP address the VLAN ID the L2 CoS priority and a flag This display includes tunnel and IPIF level configurations The following flags indicate the type of configuration Perm Permanent entry Permanent entries are configured at the IP interface level with the portCfg vlantag command Perm Net Network wide permanent entry The sam...

Page 808: ...0 10 255 255 255 0 1500 U R M 1 192 168 22 100 255 255 255 0 1500 U R M 2 192 168 22 102 255 255 255 0 1500 U R M 3 192 168 31 100 255 255 255 0 1500 U R M 4 192 168 31 102 255 255 255 0 1500 U R M 5 192 168 12 101 255 255 255 0 1500 U R M crossport 6 192 168 12 103 255 255 255 0 1500 U R M crossport 7 192 168 21 101 255 255 255 0 1500 U R M crossport 8 192 168 21 103 255 255 255 0 1500 U R M cros...

Page 809: ...00 55 0 APP 2002 2055 1 fe80 205 1eff feef 2200 55 0 APP 2002 2050 112 2002 2055 143 55 0 APP 2002 2055 1 2002 2055 143 55 0 Perm 2002 2050 112 FUNCTION Commands supported only on the Brocade 7800 and the Brocade FX8 24 SYNOPSIS portshow option all slot ve_port arguments optional_arguments DESCRIPTION Use this command to display configuration parameters and status information for FCIP tunnels and ...

Page 810: ...ng operands are supported with fciptunnel and fcipcircuit c circuit Displays the FCIP circuits within the tunnel This operand can be used with any other operand to include circuit displays t tcp Displays the TCP statistics for the circuit The c option must be specified with this option p perf Displays additional performance information for the specified FCIP tunnels q qos Displays the QoS statisti...

Page 811: ...ied GbE Port or for all GbE Ports For each GbE Port the display includes the interface status enabled or disabled the interface IPv4 Address the netmask effective MTU and annotated port flags mgmtroute Displays the management routes configured for a specified GbE Port or for all GbE Ports For each GbE Port the display includes the destination IPv4 Address the netmask the gateway address and annota...

Page 812: ...th this command This operand is optional if omitted output for all parameters is displayed There is no default parameter sid SID Displays output for the specified SID only did DID Displays output for the specified DID only lun LUN Displays output for the specified LUN only timer Displays timer information only options Affects all levels and commands globally Only one option is supported zero Displ...

Page 813: ... Tape Read and Write Emulation performance monitor xrcperf Displays the emulated XRC Performance When issued with clear this command starts the emulated XRC performance monitor structs Displays FICON control block sizes emul Displays FICON emulation control block summaries act Displays the current Active Exchange information teraperf Displays Teradata Read and Write performance parameters options ...

Page 814: ...000 FICON On FICON XRC Off FICON Tape Write On FICON Tape Read On FICON TinTir Emul On FICON Dvc Acking On FICON Read BLK ID On FICON Teradata Write On FICON Teradata Read On Tape Write Pipe 63 Tape Read Pipe 65 Tape Write Devs 32 Tape Read Devs 32 Tape Write Timer 300 Tape Max Chain 3200000 FICON OXID Base 0x8000 FICON Debug Flags 0xf7c90000 To display an FCIP tunnel with FICON disabled switch ad...

Page 815: ...ircuit Num 0 Admin Status Enabled Oper Status Up Connection Type Default Remote IP 192 168 12 200 Local IP 192 168 12 100 Metric 0 Min Comm Rt 2500000 Max Comm Rt 2500000 SACK On Min Retrans Time 100 Max Retransmits 8 Keepalive Timeout 10000 Path MTU Disc 0 VLAN ID Not Configured L2CoS VLAN Not Configured DSCP F 0 H 0 M 0 L 0 Flags 0x00000000 Circuit ID 1 12 1 Circuit Num 1 Admin Status Enabled Op...

Page 816: ...nds Compression Statistics 0 Uncompressed Bytes 0 Compressed Bytes 1 00 1 Compression Ratio Performance Statistics Overall Throughput 30945748 Output Bytes 15 Bps 30s Avg 93 Bps Lifetime Avg 70653 Output Packets 0 pkt s 30s Avg 0 pkt s Lifetime Avg 68856512 Input Bytes 305 Bps 30s Avg 208 Bps Lifetime Avg 92029 Input Packets 0 pkt s 30s Avg 0 pkt s Lifetime Avg TCP Stats 1444818696 Output Bytes 16...

Page 817: ...0000 Duration 3 days 19 hours 34 minutes 52 seconds Local Port 3225 Remote Port 49641 Max Seg Size 1420 Adaptive Rate Limiting Statistics None F Class Sender Statistics Bytes Sent 105833704 Packets Sent 1135102 Round Trip Time 0 ms HWM 0 ms Variance 0 HWM 0 Send Window 20832768 bytes scale 9 Slow Starts 0 Slow Start Threshold 16777216 Congestion Window 16778636 TCP Op State slow start Next Seq 0x0...

Page 818: ...WN 10 00 00 05 1e c3 f0 16 Peer WWN 00 00 00 00 00 00 00 00 Circuit Count 0 Flags 0x00000000 FICON Off To display the FCIP tunnel hierarchy on the Brocade FX8 24 switch admin portshow fciptunnel 1 12 hier FCIP Tunnel 1 12 High Level Tunnel Stats Operational Status Up Connected Count 1 Max Comm Rate 2500000 Compression Ratio 1 1 Compressed Bytes 0 Uncompressed Bytes 0 Bytes In 68942140 Bytes In Avg...

Page 819: ...n 1 12 1 15240915 TCP Conn 1 12 1 15240916 TCP Conn 1 12 1 15241504 TCP Conn 1 12 1 15241505 TCP Conn 1 12 1 15241506 TCP Conn 1 12 1 15241307 TCP Conn 1 12 1 15241308 TCP Conn 1 12 1 15241309 TCP Conn 1 12 1 15241111 TCP Conn 1 12 1 15241111 TCP Conn 1 12 1 15241112 Circuit 1 12 0 High Level Circuit Stats Operational Status Up Connected Count 1 Max Comm Rate 2500000 Bytes In 68941428 Bytes In Avg...

Page 820: ...0 05 1e 52 fe 00 Peer WWN 10 00 00 05 1e 39 a4 76 Circuit Count 2 Flags 0x00000000 FICON Off To display a tunnel on a Brocade FX8 24 with automatic compression enabled in summary view The A flag indicates Auto Mode switch admin portshow fciptunnel 1 21 s Tunnel Circuit OpStatus Flags Uptime TxMBps RxMBps ConnCnt CommRt Met 1 21 Up A 31m29s 0 00 0 00 2 1 21 0 1 xge1 Up 4 s 31m29s 0 00 0 00 2 2500 2...

Page 821: ...IPSec l IPSec Legacy Flags circuit s sack v VLAN Tagged x crossport 4 IPv4 6 IPv6 To display a summary view of an FCIP tunnel and its circuits on the Brocade FX8 24 with the perf option switch admin portshow fciptunnel 7 12 summary perf Tunnel Circuit TxMBps RxMBps ComRatio RTT ms ReTx OutOfSeq SlowStart 1 22 0 00 0 00 1 00 1 0 0 0 1 22 0 1 xge0 0 00 0 00 0 0 0 0 1 22 1 1 xge1 0 00 0 00 0 0 0 0 To...

Page 822: ...01 192 168 21 201 1 22 1 22 0 1 xge0 192 168 22 100 192 168 22 200 1 22 1 1 xge1 192 168 22 101 192 168 22 201 1 31 1 31 0 1 xge0 192 168 31 100 192 168 31 200 1 31 1 1 xge1 192 168 31 101 192 168 31 201 To display all FCIP circuits on the Brocade FX8 24 switch admin portshow fcipcircuit all Tunnel Circuit OpStatus Flags Uptime TxMBps RxMBps ConnCnt CommRt Met 1 12 0 1 xge1 Up 4 s 3d2m 000 0 00 1 ...

Page 823: ...tric 1 Min Comm Rt 2500000 Max Comm Rt 2500000 SACK On Min Retrans Time 100 Max Retransmits 8 Keepalive Timeout 10000 Path MTU Disc 0 VLAN ID Not Configured L2CoS VLAN Not Configured DSCP F 0 H 0 M 0 L 0 Flags 0x00000000 Circuit ID 1 21 0 Circuit Num 0 Admin Status Enabled Output truncated To display a single circuit circuit 0 on tunnel 16 with VLAN tagging configuration switch admin portshow fcip...

Page 824: ... Status Up Flow Ctrl State Off Connected Count 1 Tunnel Duration 3 days 19 hours 54 minutes 5 seconds Compression Statistics 0 Uncompressed Bytes 0 Compressed Bytes 1 00 1 Compression Ratio Performance Statistics Overall Throughput 31073824 Output Bytes 16 Bps 30s Avg 93 Bps Lifetime Avg 70932 Output Packets 0 pkt s 30s Avg 0 pkt s Lifetime Avg 69170308 Input Bytes 85 Bps 30s Avg 209 Bps Lifetime ...

Page 825: ...s 10 Bps 30s Avg 14 Bps Lifetime Avg 41359 Output Packets 0 pkt s 30s Avg 0 pkt s Lifetime Avg 7223112 Input Bytes 27 Bps 30s Avg 21 Bps Lifetime Avg 45277 Input Packets 0 pkt s 30s Avg 0 pkt s Lifetime Avg TCP Stats 318824216 Output Bytes 3419555 Output Packets 184935644 Input Bytes 3419605 Input Packets Retransmits 0 Round Trip Time 0 ms Out Of Order 0 Slow Starts 0 Performance Statistics Priori...

Page 826: ...rip Time 0 ms Out Of Order 0 Slow Starts 0 Performance Statistics Priority Low Oper Status Up Flow Ctrl State Off Connected Count 1 Duration 3 days 19 hours 57 minutes 42 seconds 0 Output Bytes 0 Bps 30s Avg 0 Bps Lifetime Avg 0 Output Packets 0 pkt s 30s Avg 0 pkt s Lifetime Avg 0 Input Bytes 0 Bps 30s Avg 0 Bps Lifetime Avg 0 Input Packets 0 pkt s 30s Avg 0 pkt s Lifetime Avg TCP Stats 308551588...

Page 827: ...anagement ge0 Enabled Interface IPv4 Address NetMask Effective MTU Flags 0 20 20 0 151 255 255 255 0 1500 Flags U Up B Broadcast D Debug L Loopback P Point2Point R Running N NoArp PR Promisc M Multicast S StaticArp LU LinkU To display the IP routes for all management interfaces on a Brocade 7800 switch admin portshow mgmtroute all Inband Management Routes Port ge0 IP Address Mask Gateway Metric Fl...

Page 828: ...ortshow xtun 16 ficon stats FICON FCIP Tunnel Statistics STATISTICS decimal Emulation Common Statistical Counts decimal TotalIngressFrames 12280588298 TotalEgressFrames 6131098914 TotalFCEgressFrames 1119802559 TotalCmds 994174108 TotalEmulDvcLvlAcks 5382 TotalEmulatedOps 393653297 MaxRetryQueueDepth 1201 MaxEgressQueueDepth 3249 TotalCUBusyResponses 0 TotalCUEndResponses 0 TotalEmulatedCUBusys 0 ...

Page 829: ...Slowdowns at Start of Chain 0 Slowdowns at End of chain 0 Single Chain Emulation Counter 0 Write Paced Count 0 Current Host side Write FDCB Count 0 Max Concurrent Write FDCB Count 0 Current Write Limited FDCB Count 0 Tape Read Emulation Statistical Counts decimal Total number of emulated Read Bytes 9724178015167 Total number of emulated Read Chains 280472860 Total number of emulated Read CCWs 2913...

Page 830: ...nding N emuTinLackPending N emuTirPending N emuTirReceived N emuTinFinalAckPend N emuTirPending N emuTinSuccessful N emuTinReceived N emuTirSent N fcrPresent N fchbValid Y FCHB Control variables tinOrigOxid 0xFFFF tirOrigOxid 0xFFFF tinAckRxid 0xFFFF tinAckOxid 0xFFFF allocChOxid 0xFFFF allocChOIdx 0x0000 tinTirOxid 0xFFFF To display FICON FCUB information FICON Images accessed through the tunnel ...

Page 831: ... 0007 UNKN No 00F2 0x155C86A7 Y Y 2 0 1 02 0007 UNKN No 00F2 0x1580E9E6 Y Y 2 0 1 02 0007 UNKN No 00F2 0x15E45825 Y Y 2 0 3 02 0007 output split and truncated To reset the Device Path Block statistics switch admin portshow xtun 16 ficon fdpb clear To display a FICON Teradata Tape or XRC emulation statistics for a specified Device Control Block switch admin portshow xtun 16 ficon fdcb 0x041008B980 ...

Page 832: ...nt 0 selectiveResetCount 1 purgePathCount 0 abortCount 0 normStatus 274408 attnStatus 0 attnBusyStatus 0 ceStatus 0 deStatus 0 retryStatus 0 immRetryStatus 0 devBusyStatus 0 cuBusyStatus 0 ceDeUxStatus 1 deUxStatus 0 pendDeStatus 0 deUcStatus 0 unusualStatus 0 chLinkBusyCount 1 cuLinkBusyCount 0 unusualStsArray 0x00000000 pGb 0x0000000000 tag 0x0285CF9E senseDeviceType 0xFF30884000000000 ingressFr...

Page 833: ...urrent index 0 FromPeerEmlHd 0 funct 2 msg 15 p1 0x0c p2 0x3066 p3 0x00000003 FromPeerEmlHd 1 funct 7 msg 8 p1 0x5f p2 0x0062 p3 0x00000000 FromPeerEmlHd 2 funct 7 msg 6 p1 0x00 p2 0x0000 p3 0x00000000 FromPeerEmlHd 3 funct 7 msg 8 p1 0x5f p2 0x0062 p3 0x00000000 convIngressOxid 0xffff convIngressOxid 0xffff timedOps 0x00043066 TERA IO TIMING last elapsedTime 0 397 maxElapsedTime 0 504 totalTime 1...

Page 834: ...r Path H State Emul Emul Rtry Emulated 0x 0x D Pipe Q d Qd Tape Ops 0x0410035B80 1763016401060400 H 0x00 N A 0000 0000 1600736 0x041004FB80 1763016401060401 H 0x00 N A 0000 0000 1289333 0x0410051B80 1763016401060402 H 0x00 N A 0000 0000 1676656 0x0410053B80 1763016401060403 H 0x00 N A 0000 0000 1415437 0x0410055B80 1763016401060404 H 0x00 N A 0000 0000 1091518 Emulated RdAvg Emulated WtAvg Read CC...

Page 835: ...ys 0 Failed Generate Frame 0 WIRE Buffer Percentages LocalFree 95 LocalLow 95 PeerFree 95 PeerLow 93 XBAR Buffer Percentages LocalFree 98 LocalLow 97 PeerFree 98 PeerLow 98 FICON Configuration Status FICON Host side Paths 5 Device Side Paths 1 FICON LPARS Connected 14 Curr LCUs 37 Total Devices 704 Current Egress Q Count 0 RetryQCnt 0 Current Free Headers 788 HdrsInUse 84 Active Emulation Count 24...

Page 836: ...rocessed 43936 Total number of emulated Write Bytes 19204226768 Number of emulated Write Chains 989882 Total number of emulated Write CCWs 989882 Average Emulated Writes Blocksize 19400 Average Writes in Emulated Chains 1 Write emulation slowdowns 114 Slowdowns at Start of Chain 0 Slowdowns at End of chain 114 Single Chain Emulation Counter 0 Write Paced Count 0 Current Host side Write FDCB Count ...

Page 837: ...SPEND Bit 4 0x00000010 1 ACCEPT_READTRACK_STATUS Bit 3 0x00000008 0 FORCE_DISABLE_ To display FICON Teradata Read and Write performance data switch admin portshow xtun 16 ficon teraperf Tera Performance Monitor Data Sample Time Period in ms 4318 Tera Write Performance Data Emulated Chains per sec 1186 Emulated CCWs per sec 1186 Ave Write Block Size 22617 Emulated Write BPS 26831514 Tera Read Perfo...

Page 838: ...IP TCP Byte Stream statistics on Byte Stream enabled tunnels History of TCP connections SnapShow capture of TCP statistics between two points in time portShow mode Displays Port Mode information portShow ficon Displays FICON parameters on FICON configured tunnels Each GbE port is associated with a TCP history which tracks the state of statistics at the moment of a TCP connection failure An entry i...

Page 839: ...Dup ACK Counter of duplicate ACKs Rtx Dup ACK Counter of retransmit packets due to duplicate ACK LPort Local port RPort Remote port Along with history the system keeps track of the following TCIP statistics which you can display with the fciptunnel snapshow option The statistic is collected from system startup onwards until it is reset with the fciptunnel snapstart option Subsequent calls to snaps...

Page 840: ...yed relative to its slot for bladed systems GbE ports on the Brocade 7500 7500E and FX 18i are numbered ge0 and ge1 See switchShow for a listing of valid ports all tunnel_id For FCIP related command options only specify all to display all FCIP tunnels or a Tunnel ID between 0 and 7 to display a single FCIP tunnel fciptunnel Displays FCIP tunnel IDs remote and local IP addresses remote and local WW...

Page 841: ...apshow Displays the TCP statistics that were collected since startup or since the statistics were reset with the snapshow command mode Displays mode of GbE port as either FCIP or not configured ficon Displays FICON emulation configuration parameters The syntax for portshow ficon is as follows portshow ficon slot ge_port all tunnel_Id arg parm clear The following arguments are supported with ficon ...

Page 842: ...D 0 Tunnel Description Test Description Remote IP Addr 192 168 10 2 Local IP Addr 192 168 44 9 Remote WWN Not Configured Local WWN 10 00 00 05 1e 38 84 65 Compssion off Fastwrite off Tape Pipelining off ACK on Min Retransmit Time 100 Keepalive Timeout 10 Max Retransmissions 8 VC QoS Mapping off DSCP Marking Control 0 DSCP Marking Data 0 TCP Byte Streaming on Status Inactive Connected Count 0 Port ...

Page 843: ...65406 0 out of order packets queued HWM 0 0 lifetime total Keepalive time since last activity detected 1 s idle connection probe interval 1 s timeout 10 s Data transfer TCP connection Local 192 168 10 2 4150 Remote 192 168 10 10 3226 Runtime parameters Send MSS 1460 Bytes Sender stats smoothed roundtrip 0 ms HWM 1 ms variance 0 HWM 562 peer advertised window 20443136 Bytes negotiated window scale ...

Page 844: ...hours 12 minutes 5 seconds QoS shaper performance stats 48152162 Bytes 2961 Bps 30s avg 6075 Bps lifetime avg 29286242 compressed Bytes 2065 Bps 30s avg 3695 Bps lifetime avg 1 64 compression ratio FC control traffic TCP connection Local 10 10 9 100 4099 Remote 10 62 0 100 3225 Performance stats 44862 output packets 2 pkt s 30s avg 5 pkt s lifetime avg 34118172 output Bytes 1655 Bps 30s avg 4305 B...

Page 845: ...on Min Retransmit Time 100 Keepalive Timeout 90 Max Retransmissions 9 VC QoS Mapping off DSCP Marking Control 10 DSCP Marking Data 62 VLAN Tagging Id 1062 L2CoS Control 1 L2CoS data 0 TCP Byte Streaming on Status Active Connected Count 1 Uptime 2 hours 13 minutes 58 seconds IKE Policy 1 Authentication Algorithm SHA 1 Encryption AES 128 Perfect Forward Secrecy on Diffie Hellman Group 14 SA Life sec...

Page 846: ...LPort RPort Event Timestamp KEEPALV TO 0 0 750 0 0 0 2309 53997568 0 0 0 0 1 0 0 0 0 4098 3226 Thu May 29 17 03 10 2008 KEEPALV TO 0 0 8 562 0 0 5093 13498368 0 0 0 0 17 0 0 0 0 4097 3225 Thu May 29 17 03 10 2008 To display a snapshot of the TCP statistics Switch admin portshow fciptunnel ge1 0 snapshow Port ge1 Tunnel ID 0 Tunnel Description Test Description Remote IP Addr 192 168 114 2 Local IP ...

Page 847: ...on off Fastwrite off Tape Pipelining off Committed Rate 900000 Kbps 0 900000 Gbps SACK on Min Retransmit Time 100 Keepalive Timeout 10 Max Retransmissions 8 VC QoS Mapping off DSCP Marking Control 0 DSCP Marking Data 0 VLAN Tagging Not Configured TCP Byte Streaming on Status Active Connected Count 1 Uptime 5 minutes 26 seconds TCP data and control statistics snapshots have been reset for tunnel 0 ...

Page 848: ...microseconds iac_e2e_latency_max 90074 microseconds iac_credits_timer_abort 0 iac_credits_timer_nobuff 0 iac_hold_head 0x00000000 iac_hold_tail 0x00000000 Internal Knobs for tuning Credit processing ip_api_data_credit_target 32 ip_api_data_credit_ratio 80 ip_api_credit_time 15 ip_api_cwnd_overcommit 29760 FC control traffic TCP connection Local 10 10 9 100 4099 Remote 10 62 0 100 3225 Data transfe...

Page 849: ...4 14 59 4 15 63 0 To display FICON EPCB for a GbE port 0 tunnel ID 1 with post display clearing of relevant statistics switch admin portshow ficon ge0 1 epcb clear To display a list of discovered devices and selected path and status information on each Get the adrs from this display for the next command switch admin portshow ficon ge0 all fdcb To display details on the FDCB specified in the adrs a...

Page 850: ...of 4 byte words received stat64_ftx Number of frames transmitted stat64_frx Number of frames received stat64_c2_frx Number of class 2 frames received stat64_c3_frx Number of class 3 frames received stat64_lc_rx Number of link control frames received stat64_mc_rx Number of multicast frames received stat64_mc_to Number of multicast timeouts stat64_mc_tx Number of multicast frames transmitted tim64_r...

Page 851: ...t64_rxClass1Frames Number of class 1 frames received stat64_aveTxFrameSize Average Tx Frame size based on the word and frame counts during the last five seconds stat64_aveRxFrameSize Average Rx Frame size based on the word and frame counts during the last five seconds The following counters provided by SNMP are displayed with portStats64Show long on switches running Fabric OS v6 4 0 or later swCon...

Page 852: ...l Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details This command is not supported on FCoE ports OPERANDS This command has the following operands slot For bladed systems only specify the slot number of the port to be displayed followed by a slash port Specify a port number to be displayed relative to ...

Page 853: ...outside of frames er64_disc_c3 0 top_int Class 3 frames discarded 0 bottom_int Class 3 frames discarded stat64_rateTxFrame 0 Tx frame rate fr sec stat64_rateRxFrame 0 Rx frame rate fr sec stat64_rateTxPeakFrame 9 Tx peak frame rate fr sec stat64_rateRxPeakFrame 9 Rx peak frame rate fr sec stat64_rateTxWord 0 Tx Word rate words sec stat64_rateRxWord 0 Rx Word rate words sec stat64_rateTxPeakWord 26...

Page 854: ...how 22 er64_type2_miss 0 frames with FTB type 2 miss er64_type6_miss 0 frames with FTB type 6 miss er64_zone_miss 0 frames with hard zoning miss er64_lun_zone_miss 0 frames with LUN zoning miss lli64 0 Low level interrupts SEE ALSO portStatsClear portStatsShow ...

Page 855: ... Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details This command is not supported on FCoE ports OPERANDS This command has the following operands slot For bladed systems only specify the slot number of the port to be cleared followed by a slash port Clears a single port identified by the port number re...

Page 856: ... hardware statistics for multiple port ranges specified by their index numbers switch admin portstatsclear i 32 40 50 56 To clear hardware statistics for all ports on slots 3 5 switch admin portstatsclear s 3 5 To clear hardware statistics for all ports on slots 3 5 and 7 10 switch admin portstatsclear s 3 5 7 10 SEE ALSO portStats64Show portStatsShow portSwapDisable portSwapShow switchShow ...

Page 857: ... switchShow for a listing of valid ports slots and port index numbers Specifying multiple ports with the index i or slot s option is supported only if PortSwap is disabled They are not supported on GbE ports and configured F_Port trunks Use the i option without a port index to display the portSwap status or alternately use portSwapShow The command output may include the following fields Tx indicat...

Page 858: ...intervals of 2 5 microseconds microseconds and the counter is incremented if the condition is true Each sample represents 2 5 microseconds of time with zero Tx BB Credit An increment of this counter means that the frames could not be send to the attached device for 2 5 microseconds indicating degraded performance platform and port specific er_enc_in The number of encoding errors inside frames er_c...

Page 859: ...the FL_Port entered OPEN state transfer The number of times the FL_Port entered TRANSFER state opened The number of times the FL_Port entered OPENED state starve_stop The number of loop tenancies stopped due to starvation fl_tenancy The number of times the FL_Port had a loop tenancy nl_tenancy The number of times the NL_Port had a loop tenancy zero_tenancy The number of times a zero tenancy occurr...

Page 860: ...rst in first out FIFO queue was observed on the GbE port ip_err_hdr_cksum The number of checksum errors observed on the GbE port ip_err_tcp_data_chksum The number of IP TCP data checksum errors observed on the GbE port NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command...

Page 861: ... display the basic set of statistics for port 1 13 on a DCX backbone switch admin portstatsshow 13 stat_wtx 0 4 byte words transmitted stat_wrx 0 4 byte words received stat_ftx 0 Frames transmitted stat_frx 0 Frames received stat_c2_frx 0 Class 2 frames received stat_c3_frx 0 Class 3 frames received stat_lc_rx 0 Link control frames received stat_mc_rx 0 Multicast frames received stat_mc_to 0 Multi...

Page 862: ...es ge_stat_tx_octets 152411630 GE transmitted octets ge_stat_tx_ucast_frms 1523907 GE transmitted unicast frames ge_stat_tx_mcast_frms 0 GE transmitted multicast frames ge_stat_tx_bcast_frms 9 GE transmitted broadcast frames ge_stat_tx_vlan_frms 0 GE transmitted vlan frames ge_stat_tx_pause_frms 0 GE transmitted pause frames ge_stat_rx_frms 1512154 GE received frames ge_stat_rx_octets 149255230 GE...

Page 863: ...IP transmitted comp bytes ip_out_octets 159896 IP transmitted uncomp bytes ip_out_pkts 3476 IP transmitted packets ip_out_ucast_pkts 3476 IP transmitted unicast packets ip_out_bcast_pkts 0 IP transmitted broadcast packets ip_out_mcast_pkts 0 IP transmitted multicast packets ip_in_octets 0 IP received comp bytes ip_in_octets 0 IP received uncompbytes ip_in_pkts 0 IP received packets ip_in_ucast_pkt...

Page 864: ...ilability for details You cannot swap E_ports that are configured as part of a TI zone The TI zone information is lost when you swap the E_ports To work around this issue reconfigure your TI zones rather than swapping the ports OPERANDS This command has the following operands slot1 For bladed systems only specifies the slot number of the first port whose area number is to be swapped followed by a ...

Page 865: ...stent across reboots and power cycles Enabling or disabling the PortSwap feature does not affect previously performed PortSwap operations NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To disable the PortSwap feature ...

Page 866: ... is persistent across reboots and power cycles Enabling or disabling the PortSwap feature does not affect previously performed PortSwap operations NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To enable the PortSwap ...

Page 867: ...place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To display a switch with PortSwap enabled and information for swapped ports Console message 2009 10 09 21 22 45 PSWP 1001 482 SLOT 6 FID 51 INFO DCX_105_51 PID for port 12 0 and port 12 63 are swapped New PID for port 12 0 is 0x697000 and port 12 63 is 0x69e3c0 switch admin port...

Page 868: ... port using a short wavelength cable a long wavelength port should be connected to a long wavelength port and a copper port should be connected to a copper port Only one frame is transmitted and received at any given time The port LEDs flicker green while the test is running This command supports E_Ports F_Ports must support ELS Echo L_Port and N N loopback ports In addition on switches running Fa...

Page 869: ...mber of frames per port to execute this test Specify 0 to run the test in timeout mode or specify 1 to run the test indefinitely The default value is 20 userdelay time Specifies the delay between frames sent by portTest in milliseconds The default value is 10 milliseconds timeout time Specifies the number of seconds to run the test Setting the iteration to 0 puts the portTest process into timeout ...

Page 870: ...ommand Reference 53 1001764 01 portTest 22 5 All N N loopback ports EXAMPLES To run a functional test on an active switch switch admin porttest ports 1 1 1 3 SEE ALSO portLoopbackTest portTestShow spinFab stopPortTest ...

Page 871: ...Type Type of port tested PortState Current State of portTest Values are NO TEST TESTING or TEST DONE PortTypeToTest Groups of ports tested Values are ALL_PORTS ALL_E_PORTS ALL_L_PORTS ALL_F_PORTS ALL_LB_PORTS or SINGLE_PORT Pattern The pattern of the test packets payload Seed The seed value used with the selected pattern The default seed value is 0xaa UserDelay The delay between frames sent by por...

Page 872: ...splays test results for the specified ports This operand is optional if omitted data for all ports are displayed Refer to the itemList help page for further details EXAMPLES To display information from portTest switch admin porttestshow 1 Port 1 PASS PortType OTHER PortState NO TEST PortInternalState INIT PortTypeToTest NO_TEST Pattern 0x0 Seed 0x0 UserDelay 0 TotalIteration 0 CurrentIteration 0 T...

Page 873: ...e one or more of the following actions Send an SNMP message Log a RASlog message Send an E mail alert Locks the port log Fence the port if port fencing is enabled not applicable to E_Ports Refer to portFencing help for more information Class 3 frames may be discarded on a port because of timeout destination unreachable or other reasons This command only monitors Class 3 frames that are discarded b...

Page 874: ... or displays all optical F_Ports fcu port Configures or displays all copper F_Ports This operand is supported only on embedded platforms and only on copper ports port Configures or displays all physical ports ve port Configures or displays all VE_Ports Only a subset of areas can be configured for this port type When setting VE_Port thresholds for the packet loss area PKTLOSS the threshold value ac...

Page 875: ... intervals include the following day Samples are compared once a day hour Samples are compared once every hour minute Samples are compared once every minute highthreshold value value Specifies the high threshold value for triggering a specified alert action To change the default value provide an integer value lowthreshold value value Specifies the low threshold for triggering a specified alert act...

Page 876: ...d area type with this command Thresholds and alarm levels are optional with this command if omitted all nonpersistent configurations for the specified port type and area type are canceled show Displays the threshold configuration or run time status for all configured port types and areas You can optionally specify a port type to display the threshold for ports of that type only The display include...

Page 877: ...2 trigger above action email switch admin portthconfig set port area crc highthreshold value 2 trigger below action email switch admin portthconfig set port area crc lowthreshold value 1 trigger above action email switch admin portthconfig set port area crc lowthreshold value 1 trigger below action email To apply the new custom settings so they become effective switch admin portthconfig apply port...

Page 878: ...Action None Trigger Below Action None Default TimeBase Minute Value 1000 Trigger Above Action None Trigger Below Action None Low Custom TimeBase Minute Value 0 Trigger Above Action None Trigger Belo Action None Default TimeBase Minute Value 0 Trigger Above Action None Trigger Below Action None Buffer Custom Value 100 Default Value 100 Port persistence time 18s Area ITW ThLevel Def ActLevel Def Hig...

Page 879: ...0 Trigger Above Action None Trigger Below Action None Low Custom TimeBase Minute Value 0 Trigger Above Action None Trigger Below Action None Default TimeBase Minute Value 0 Trigger Above Action None Trigger Below Action None output truncated To display threshold configuration and current status for E_Port CRC errors switch admin portthconfig show e port area crc PortType E port Area CRC ThLevel De...

Page 880: ...0006 n a 0 Info Pause E port CRC 000007 n a 0 Info Pause E port CRC 000008 n a 0 Info Pause E port CRC 000009 n a 0 Info Pause E port CRC 000010 n a 0 Info Pause E port CRC 000011 n a 0 Info Pause E port CRC 000012 n a 0 Info Pause output truncated switch admin portthconfig continue e port area all port all switch admin portthconfig show e port current PortType Area PortNo C Value State Monitoring...

Page 881: ... n a 0 Info Continue E port CRC 000088 n a 0 Info Continue E port CRC 000089 n a 0 Info Continue E port CRC 000090 n a 0 Info Continue E port CRC 000091 n a 0 Info Continue E port CRC 000092 n a 0 Info Continue E port CRC 000093 n a 0 Info Continue E port CRC 000094 n a 0 Info Continue E port CRC 000095 n a 0 Info Continue E port CRC 000128 n a 0 Info Continue E port CRC 000129 n a 0 Info Continue...

Page 882: ...fter going offline and 2 to increase N_Port bandwidth Assigning a TA to a port or trunk group enables F_Port masterless trunking on that port or trunk group When a TA is assigned to a port or trunk group the ports immediately acquires the TA as the area of their process IDs PID Likewise when a TA is removed from a port or trunk group the ports reverts to the default area as their PID Use the show ...

Page 883: ...omatically sets the minimum deskew value of the shortest F_Port trunk travel time to 15 Master Identifies the master port of the trunk group Execution of this command is subject to the following restrictions Only F_Port trunk ports are allowed to be part of a TA E F L EX_Port will be persistently disabled Private L_Ports remain online but will not run traffic Only one trunk master per TA is permit...

Page 884: ...ber On single processor switches specifies the port area number for the static TA to be created The TA must fall within the 8 port trunk group starting from port 0 on a switch or blade The TA must be a default area of an existing port in a given port group However you may add ports to the trunk group even when a trunk group has already been assigned by using the same area of the octet trunk group ...

Page 885: ...A 2 Enable Trunk Area for ports 10 11 with area number 37 switch admin porttrunkarea enable 10 11 index 11 2009 05 15 12 43 10 SWCH 1012 60 FID 128 INFO sw0 Trunk Area 11 has been enabled for one or more ports Trunk area 11 enabled for ports 10 and 11 3 Re enable ports 10 11 by executing portenable port for each port in the TA 4 Show switch port information switch admin switchshow Index Port Addre...

Page 886: ...se class platform including ports 13 and 14 on slot 10 with port index of 125 1 Disable the ports to be included in the TA 2 Enable TA for ports 13 and 14 on slot 10 with port index of 125 switch admin porttrunkarea enable 10 13 14 index 125 Trunk index 125 enabled for ports 10 13 and 10 14 3 Show the TA port configuration ports still disabled switch admin porttrunkarea show enabled Slot Port Type...

Page 887: ... to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To display the zone membership information of ports switch user portzoneshow OUTPUT TRUNCATED PORT 160 160 Offline PORT 161 161 Offline PORT 162 162 Offline PORT 163 163 Offline PORT 164 164 Offline PORT 165 165 Offl...

Page 888: ... power off list cannot be processed However if the system is running on two power supplies this is not recommended and one goes into a predicted fail state in which the power supply is still supplying power the power off list is processed as described The power off list does not affect the order in which slots are powered on On power on or when an additional power supply is added slots are process...

Page 889: ...8 9 7th slot to be powered off 7 8 8 8 8th slot to be powered off 7 7 7 7 Old POL New POL Power Off Order 10 1 1st 9 2 2nd 8 3 3rd 7 4 4th 4 10 5th 3 9 6th 2 8 7th 1 7 8th Proceed to change the POL order yes y no n no y SEE ALSO chassisShow powerOffListShow psShow slotPowerOff slotPowerOn slotShow ...

Page 890: ...s all system operations terminate immediately and the power off list cannot be processed However if the system is running on two power supplies this is not recommended and one goes into a predicted fail state in which the power supply is still supplying power the power off list is processed as described NOTES Command output may vary depending on the hardware platform Control processor CP blades ar...

Page 891: ... off fuse blown or other internal error For certain switch models the OEM serial ID data displays after each power supply status line NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To view the status of the power supp...

Page 892: ...leConfig command you could define a special admin role called myzonesec and assign access to this role for both the zoning and the userManagement class Restriction by RBAC access level You can further restrict access by setting RBAC one of the following access levels for the role The RBAC permissions are set per class O observe OM observe modify N none not available Use the show option to display ...

Page 893: ... of the predefined Fabric OS roles copy Clones an existing user defined role by copying an existing role to a new role name The new role inherits all the classes and permissions of the source role You can further modify the newly created role The following operands are required new_role The name for the new role must be unique it is case insensitive and can contain only alpha characters The role n...

Page 894: ... c zoning p OM switch admin roleconfig show myzonesec Role Name myzonesec Description Zone and Security Admin RBAC Class Permission Security O Zoning OM Role permissions changed successfully To copy the role myszonesec switch admin roleconfig copy superrole r myzonesec Role superrole is copied successfully To delete a role switch admin roleconfig delete r myzonesec You are going to delete a user d...

Page 895: ...ruption If HA is not in sync and reboot f is issued on the Active CP the Standby CP takes over as the Active CP and traffic is disrupted When HA is disabled and reboot or reboot f is issued on the Active CP both the Active and Standby CPs reboot with the original mastership retained The original Active CP remains the Active CP after the reboot and the original Standby CP remains the Standby CP Aft...

Page 896: ... root pts 0 Sun Feb 28 19 49 45 2010 The system is going down for reboot NOW To reboot a CP on a DCX when haFailover is disabled switch admin reboot This command is being run on a control processor CP based system Because HA is disabled it will cause both active CP and the standby CP to reboot After reboot the HA will be enabled Do you want to continue y n y Broadcast message from root pts 0 Sun F...

Page 897: ...nce Tuning policy bcastShow Print broadcast tree information dlsReset Turn off Dynamic Load Sharing dlsSet Turn on Dynamic Load Sharing dlsShow Print state of Dynamic Load Sharing fspfShow Print FSPF global information interfaceShow Print FSPF interface information iodReset Turn off In Order Delivery iodSet Turn on In Order Delivery iodShow Print state of In Order Delivery linkCost Set or print th...

Page 898: ... 0 the maximum size is 256 Kilobytes NOTES The effective security DB size is the lowest supported by the fabric The presence of a Standby CP that runs an earlier version of the operating system will drop the effective security DB size on an Active CP that runs Fabric OS v6 2 0 The Brocade 200E is unable to handle the maximum DB size supported in v6 2 0 and issues a compact flash warning when the a...

Page 899: ...mand is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands show Lists the WWNs for which a shared secret is configured set Sets shared secrets with a WWN This command is interactive When setting secrets for an entry of an EX_Port the ...

Page 900: ... that authenticates peer Press Enter to start setting up shared secrets Enter WWN Domain or switch name Leave blank when done 10 00 00 60 69 80 05 14 Enter peer secret Re enter peer secret Enter local secret Re enter local secret Enter WWN Domain or switch name Leave blank when done Are you done yes y no n no y Saving data to key store Done To delete the entire secret key database switch admin sec...

Page 901: ...mport ldapcacert fcapswcert fcapcacert config cacert config swcert nowarn enable https protocol ftp scp ipaddr IP address remotedir remote directory certname certificate name login login name password password seccertutil show ldapcacert fcapall fcapswcert filename DESCRIPTION Use this command to manage third party certificates on a switch including Public Key Infrastructure PKI based certificates...

Page 902: ...s are generated only after all existing CSRs and certificates have been deleted nowarn Specifies that no warning is given when overwriting or deleting data If this operand is omitted the command prompts for confirmation before existing CSRs and certificates are deleted delkey Deletes all public private key pairs with the exception of Encryption related certificates and key pairs This command promp...

Page 903: ...letes the specified certificate Specify one of the following operands ldapcacert Deletes all LDAP CA certificates You must specify a file name when deleting the LDAP CA certificates All LDAP certificates are concatenated in a single file Use show ldapcacert to list that file name on the switch You cannot delete an individual certificate fcapcacert Deletes the FCAP CA certificate fcapswcert Deletes...

Page 904: ...a CA after sending the CSR to the CA Specify one of the following certificates ldapcacert Imports an LDAP CA certificate fcapswcert Imports an FCAP switch certificate fcapcacert Imports an FCAP CA certificate config cacert Imports a CA certificate config swcert nowarn Imports an SSL certificate If nowarn is specified the SSL certificate import is blocked without warning if the certificate is inval...

Page 905: ... mode switch admin seccertutil genkey Generating a new key pair will automatically do the following 1 Delete all existing CSRs 2 Delete all existing certificates 3 Reset the certificate filename to none 4 Disable secure protocols Continue yes y no n no y Select key size 1024 or 2048 1024 Generating new rsa public private key pair Done To generate a public private key pair in noninteractive mode sw...

Page 906: ...r IP address 195 168 38 206 Enter remote directory users home remote_certs Enter certificate name must have crt cer or pem suffix ldap cer Enter Login Name mylogin Enter Password password Success imported certificate ldap cert To import an LDAP certificate from a remote host to the local switch in noninteractive mode switch admin seccertutil import ldapcacert protocol ftp ipaddr 195 168 38 206 rem...

Page 907: ...ed Secure http has been enabled To import a PKI based certificate with configure and enable option in noninteractive mode switch admin seccertutil import config swcert enable https protocol ftp ipaddr 195 168 38 206 remotedir users home remote_certs certname file crt login abcd password passwd Success imported certificate file crt Certificate file in configuration has been updated Secure http has ...

Page 908: ...lete an LDAP CA certificate in interactive mode switch admin seccertutil delete ldapcacert filename pem WARNING About to delete certificate filename cer ARE YOU SURE yes y no n no y Deleted LDAP certificate successfully To delete an LDAP CA certificate in noninteractive mode switch admin seccertutil delete ldapcacert filename pem Deleted LDAP certificate successfully To delete all FCAP PKI objects...

Page 909: ...Exist To list all LDAP certificates on a switch switch admin seccertutil show ldapcacert List of ldap ca certificate files Sample cer To display the content of the CSR one page at a time switch admin seccertutil showcsr more To display the contents of an FCAP SW certificate switch admin seccertutil show fcapswcert To display the contents of a PKI based or LDAP CA certificate switch admin seccertut...

Page 910: ... limited to 1 Megabyte For switches running earlier versions of Fabric OS up to v5 3 0 the maximum size is 256 Kilobytes The effective security DB size is the lowest supported by the fabric The presence of a Standby CP that runs an earlier version of the operating system drops the effective security DB size on an Active CP that runs Fabric OS v6 2 0 or later NOTES The execution of this command is ...

Page 911: ...cution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To view the current security state switch admin secglobalshow General Security Information flag 1 saveflag 0 transId 0 Queue Size 0 final Rca 0 reliablemsg 0 reliablePhase 0 Primary p...

Page 912: ... Zone sum e04b215b sec_db free primaryDLPhase 0 wwnDL State pid tid key sec usec LOG CACHE 14 08 50 813905136 secipadm_ipchange receives notification 14 08 50 850588912 secProcessIPChange starts processing 14 08 50 850588912 secProcessIPChange acks completion Output truncated SEE ALSO secActiveSize secDefineSize ...

Page 913: ...secauthsecret Creates Manages DHCHAP secret key details seccertutil Creates Manages Displays third party PKI certificates secdefinesize Displays size of the defined security database secglobalshow Displays current internal security state information secpolicyabort Aborts changes to defined policy secpolicyactivate Activates all policy sets secpolicyadd Adds members to an existing policy secpolicyc...

Page 914: ...ed this command can be issued only from the Primary FCS switch Only the user who made the changes to the defined database may use this command to abort them The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To abort all change...

Page 915: ...et then nothing is done After activation the defined policy set becomes the Active Policy Set Use secPolicyShow to display the members of an existing policy in the Active or Defined Security Policy Sets NOTES The behavior of this command is the same for tolerant and strict fabric wide consistency When an FCS policy is enabled this command can be issued only from the Primary FCS switch Any modifica...

Page 916: ...g to the logical switch Automatic policy distribution for DCC SCC and FCS remains unchanged in Fabric OS v6 2 0 and can be configured on a per logical switch basis NOTES When an FCS policy is enabled this command can be issued only from the Primary FCS switch The secpolicyadd command can be issued on all switches for SCC and DCC policies as long as fabric wide consistency policy is not set for the...

Page 917: ...parated by commas and enclosed in either brackets or parentheses for example 2 4 6 Ports enclosed in brackets include the devices currently attached to those ports The following examples illustrate several ways to specify the port values 1 6 Selects ports 1 through 6 Selects all ports on the switch 3 9 Selects ports 3 and 9 and all devices attached to those ports 1 3 5 Selects ports 1 through 3 an...

Page 918: ...ou create a DCC lockdown policy on a logical switch the DCC policy is created for each port in the chassis even though the ports are not currently present in the local logical switch This is done to provision the DCC policy for the ports that may be moved later If a policy seems stale at any point use the secPolicyDelete command to remove all stale DCC policies Fabric wide consistency policies can...

Page 919: ...in either brackets or parentheses for example 2 4 6 Ports enclosed in brackets include the devices currently attached to those ports The following examples illustrate several ways to specify the port values 1 6 Selects ports 1 through 6 Selects all ports on the switch 3 9 Selects ports 3 and 9 and all devices attached to those ports 1 3 5 Selects ports 1 through 3 and 5 and all devices attached to...

Page 920: ... Worldwide Name Enet IP Addr FC IP Addr Name 2 fffc02 10 00 00 05 1e 39 5f 67 10 32 69 53 10 20 30 53 sw1 fec0 60 69bc 60 260 69ff fe80 d4a 4 fffc04 10 00 00 05 1e 04 ef 0e 10 32 69 49 10 20 30 49 sw2 fec0 60 69bc 54 205 1eff fe04 ef0e 200 fffcc8 10 00 00 05 1e 35 cd ef 10 32 69 117 10 20 30 117 nSW4100_98 3 Create a SCC policy that includes switches with domain IDs 2 and 4 switch admin secpolicyc...

Page 921: ...ilability for details OPERANDS The following operand is required name Specify the name of a security policy to delete The policy name must be capitalized Quotation marks are optional Once a security policy is deleted fabric wide switch access through that method is unrestricted Valid security policy names include the following DCC_POLICY_nnn Deletes the specified Device Connection Control DCC poli...

Page 922: ...tale DCC policies in the fabric primaryfcs admin secpolicydelete ALL_STALE_DCC_POLICY About to clear all STALE DCC policies ARE YOU SURE yes y no n no y SEE ALSO secPolicyAbort secPolicyActivate secPolicyAdd secPolicyCreate secPolicyDump secPolicyRemove secPolicySave secPolicyShow ...

Page 923: ...databases are displayed name Specifies the security policy for which to display the members Valid values for this operand include the following DCC_POLICY_nnn FCS_POLICY SCC_POLICY The specified policy name must be capitalized and enclosed in double quotation marks The DCC_POLICY_nnn name has the common prefix DCC_POLICY_ followed by a string of user defined characters These characters do not have...

Page 924: ...ll security policies in the defined database switch admin secpolicydump Defined ___________________________________________________ DEFINED POLICY SET FCS_POLICY Pos Primary WWN DId swName 1 Yes 10 00 00 05 1e 39 5f 67 3 NeptuneSec 2 No 10 00 00 05 1e 90 09 4a Unknown SCC_POLICY WWN DId swName 10 00 00 05 1e 39 5f 67 3 NeptuneSec 10 00 00 05 1e 90 09 4a Unknown DCC_POLICY_h1 Type WWN DId swName Sw...

Page 925: ...0 00 00 05 1e 39 5f 67 3 NeptuneSec 10 00 00 05 1e 90 09 4a Unknown To display the SCC policies in the active database switch admin secpolicydump Active SCC_POLICY __________________________________________________ ACTIVE POLICY SET SCC_POLICY WWN DId swName 10 00 00 05 1e 39 5f 67 3 NeptuneSec 10 00 00 05 1e 90 09 4a Unknown SEE ALSO secPolicyAbort secPolicyActivate secPolicyAdd secPolicyCreate s...

Page 926: ...CS switch you want to move to Specify the position to which you want to move the FCS switch EXAMPLES To move the backup FCS switch from position 2 to position 3 in the FCS list interactively switch admin secpolicyfcsmove Pos Primary WWN DId swName 1 Yes 10 00 00 60 69 10 02 18 1 switch5 2 No 10 00 00 60 69 00 00 5a 2 switch60 3 No 10 00 00 60 69 00 00 13 3 switch73 Please enter position you d like...

Page 927: ...witch2 switch admin secpolicyactivate About to overwrite the current Active Policy Set ARE YOU SURE yes y no n no y secpolicyactivate command was completed successfully switch admin secpolicyshow ________________________________________________ ACTIVE POLICY SET FCS_POLICY Pos Primary WWN DId swName 1 Yes 10 00 00 05 1e 35 cd ef 200 switch3 2 No 10 00 00 05 1e 39 5f 67 2 switch1 3 No 10 00 00 05 1...

Page 928: ...wed by a string of user defined characters These characters do not have to be capitalized like regular policy names but are case sensitive member Specify a member or list of members to delete from the policy The list must be enclosed in quotation marks members must be separated by semicolons This operand is required Depending on the policy type members can be specified using IP address WWN domain ...

Page 929: ...tached to those ports Selects all ports on the switch and devices currently attached to those ports EXAMPLES To remove a member that has a WWN of 12 24 45 10 0a 67 00 40 from SCC policy switch admin secpolicyremove SCC_POLICY 12 24 45 10 0a 67 00 40 Member s have been removed from SCC_POLICY SEE ALSO secPolicyAbort secPolicyActivate secPolicyAdd secPolicyCreate secPolicyDelete secPolicyDump secPol...

Page 930: ...switch operation A fabric wide consistency configuration does not affect the behavior of this command The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To save a defined policy set to persistent memory switch admin secpolicysa...

Page 931: ...tation marks Valid values are Active Defined or an asterisk for both Active and Defined This operand is optional If not specified all databases are displayed name Specify the name of the security policy you want to view in quotation marks The specified policy name must be capitalized This operand is optional Valid values for this operand include the following DCC_POLICY_nnn FCS_POLICY SCC_POLICY T...

Page 932: ..._______________ DEFINED POLICY FCS_POLICY Pos Primary WWN DId swName __________________________________________________ 1 Yes 10 00 00 60 69 30 15 5c 1 primaryfcs 2 No 10 00 00 60 69 30 1e 62 4 switch ___________________________________________________ SEE ALSO fddCfg secPolicyAbort secPolicyActivate secPolicyAdd secPolicyCreate secPolicyDelete secPolicyDump secPolicyRemove secPolicySave ...

Page 933: ...of a security statistic you would like to reset The specified policy name must be capitalized If executed on the primary FCS specify an asterisk to reset all security policies Valid values for this operand include the following TELNET_POLICY HTTP_POLICY SCC_POLICY DCC_POLICY LOGIN INVALID_CERT AUTH FAIL TS_OUT_SYNC NO_FCS INCOMP_DB ILLEGAL_CMD To access DCC policies enter DCC_POLICY Violations are...

Page 934: ...Fabric OS Command Reference 53 1001764 01 secStatsReset 22 To reset DCC_POLICY statistics on domains 1 and 69 primaryfcs admin secstatsreset DCC_POLICY 1 69 Reset DCC_POLICY statistic SEE ALSO secStatsShow ...

Page 935: ... local switch or chassis The following operands are optional name Specify the name of the security statistic you want to view The specified policy name must be capitalized If executed on the primary FCS specify an asterisk to represent all security policies in the fabric Valid values for this operand include the following TELNET_POLICY HTTP_POLICY SCC_POLICY DCC_POLICY LOGIN INVALID_CERT AUTH FAIL...

Page 936: ... LOGIN Fabric Statistics Domain 1 Name Value LOGIN 2 To display statistic information for TELNET_POLICY for all switches in the fabric from the primary FCS switch primaryfsc admin secstatsshow TELNET_POLICY Fabric Statistics Domain 1 Name Value TELNET_POLICY 0 Domain 69 Name Value TELNET_POLICY 0 Domain 70 Name Value TELNET_POLICY 0 SEE ALSO secStatsReset ...

Page 937: ... Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To view all sensor values switch admin sensorshow sensor 1 Temperature is Ok value is 39 C sensor 2 Temperature is Absent sensor 3 Temperature is Absent sensor 4 Temperature is Absent sensor 5 Temperature is Ok value is 26 C sensor 6 Temperature is Ok value is 27 C sensor 7 Fan is Ok...

Page 938: ...ect immediately and are saved persistently NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details This command is applicable only to Brocade FC8 16 blades in slots 2 and or 7 of a DCX 4S chassis with a CR4S 8 core blade OPERANDS This command has th...

Page 939: ...isable SerDes tuning mode and reset the SerDes values to defaults switch admin serdestunemode reset serdestunemode is turned ff New serdes values reset on slot 2 New serdes values reset on slot 7 switch admin serdestunemode show serdestunemode is disabled SEE ALSO None ...

Page 940: ...ch context FID 128 When the context is changed switch wide commands apply to the new logical switch context You must have chassis permissions to access all logical switches in the chassis and to use the setContext command to change the current context to any partition configured on the chassis A user without chassis permissions can change contexts only within the list of FIDs specified in the user...

Page 941: ... to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands module_name Specify the name of the module for which you want to view the debug and verbosity levels Module names are case sensitive This operand is optional if omitted this command displays the debug and verbose level for all modules level Specify the debug level...

Page 942: ...command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands module_name Specify the name of the module for which the verbose level is to be set module names are case sensitive level Specify the verbose level 0 to 9 EXAMPLES To set t...

Page 943: ...power on time for the switch in years and hours For smart SFPs including mini SFPs this command displays additional fields including module temperature voltage received optical power transmitted optical power long wave only laser diode drive current optional status control register alarm and warning flags as well as high and low thresholds programmed on the SFPs A Can not read Serial Data message ...

Page 944: ...icense The switch does not have a Fabric Watch License Unknown This state displays for 8G 4G and 2G SPF types not supported by this feature Paused Health monitoring is not enabled on the switch The detailed view displays the total number of Fabric Watch state transitions for each SFP To configure the SFP state changes use the fwFruCfg command The detailed view also displays the power on time for 1...

Page 945: ...ial No HAA110491000J62 Speed 4 8 16_Gbps Health Green Output truncated To display detailed information about a single 16G QSPP switch user sfpshow 8 62 QSFP No 8 Channel No 3 Identifier 13 QSFP Connector 12 MPO Parallel Optic Transceiver 0000000000000000 id Encoding 5 64B66B Baud Rate 140 units 100 megabaud Length 9u 0 units km Length 9u 25 units 100 meters Length 50u 0 units 10 meters Length 62 5...

Page 946: ...s 10 meters Length Cu 0 units 1 meter Vendor Name BROCADE Vendor OUI 00 05 1e Vendor PN 57 0000088 01 Vendor Rev A Wavelength 850 units nm Options 003a Loss_of_Sig Tx_Fault Tx_Disable BR Max 0 BR Min 0 Serial No HAA110491000HJ2 Date Code 101208 DD Type 0x68 Enh Options 0xfa Status Ctrl 0xb2 Pwr On Time 0 17 years 1498 hours Alarm flags 0 1 0x0 0x40 Warn Flags 0 1 0x0 0x40 Alarm Warn low high low h...

Page 947: ...h 62 5u 3 units 10 meters Length Cu 0 units 1 meter Vendor Name BROCADE Vendor OUI 00 05 21 Vendor PN 57 1000046 01 Vendor Rev A Wavelength 850 units nm Options 001a Loss_of_Sig Tx_Fault Tx_Disable BR Max 0 BR Min 0 Serial No UYA109301009212 Date Code 090723 DD Type 0x68 Enh Options 0xf0 Status Ctrl 0x80 Alarm flags 0 1 0x0 0x0 Warn Flags 0 1 0x0 0x0 Alarm Warn low high low high Temperature 30 Cen...

Page 948: ... port 0 on an FR4 18i blade CS48000 admin sfpshow 10 ge0 Identifier 3 SFP Connector 7 LC Transceiver 050c402000000000 100 200_MB s M5 M6 sw Inter_dist Encoding 1 8B10B Baud Rate 21 units 100 megabaud Length 9u 0 units km Length 9u 0 units 100 meters Length 50u 30 units 10 meters Length 62 5u 15 units 10 meters Length Cu 0 units 1 meter Vendor Name AGILENT Vendor OUI 00 30 d3 Vendor PN HFBR 5720L V...

Page 949: ...port This command cannot run from a Telnet session This setting is saved in the configuration database therefore it is persistent across reboots and power cycles NOTES On dual CP systems a reboot on the standby CP is required for this command to take effect No action is required on the active CP The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in ...

Page 950: ...herefore it is persistent across reboots and power cycles NOTES On dual CP systems a reboot on the standby CP is required for this command to take effect No action is required on the active CP If flow control is enabled and if the console output is suspended for an extended period of time the switch might reboot It is recommended to disable the flow control using shellFlowControlDisable The execut...

Page 951: ... off NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operand slot Specify the slot number of the blade to be powered down This operand is required EXAMPLES To power off blade unit 3 switch admin slotpo...

Page 952: ...ts such slots as being in the state of INSERTED NOT POWERED ON NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operand slot Specify the slot number of the blade to be powered on This operand is require...

Page 953: ... the model name associated with an unsupported blade When no operand is specified slotShow displays the blade type blade ID and status for each slot In this view the fields and their possible values are as follows Slot Displays the physical slot number Blade Type Displays the blade type as one of the following SW BLADE The blade is a switch CP BLADE The blade is a control processor CORE BLADE The ...

Page 954: ...16 4 core blade Status Displays the status of the blade as one of the following VACANT The slot is empty INSERTED NOT POWERED ON The blade is present in the slot but is turned off POWERING UP The blade is present and powering on LOADING The blade is present powered on and loading the initial configuration DIAG RUNNING POST1 The blade is present powered on and running the POST power on self test DI...

Page 955: ...mponents is included but not listed Total alternating current AC power consumption in Watts AC efficiency as a percentage of total and BTU Power efficiency in Watts port and Watts Gb m In addition to the basic slot status view displays the Brocade model name for each blade EXAMPLES To display the status of all slots on a DCX 8510 8 switch user slotshow Slot Blade Type ID Status 1 UNKNOWN VACANT 2 ...

Page 956: ... 77 130 ENABLED 12 SW BLADE 96 180 ENABLED Total DC Power Consumption 2195 watts Total AC Power Consumption 2438 watts AC 90 efficiency 8321 BTU Power Efficiency 0 85 watts per port 0 12 watts per Gb To display the Brocade model name for each blade on a Brocade DCX 8510 4 switch user slotshow m Slot Blade Type ID Model Name Status 1 UNKNOWN VACANT 2 SW BLADE 96 FC16 48 ENABLED 3 CORE BLADE 99 CR16...

Page 957: ...h user slotshow p Slot Blade Type ID DC Power Status Consumption 1 SW BLADE 77 130 ENABLED 2 SW BLADE 51 115 ENABLED 3 CORE BLADE 46 60 ENABLED 4 CP BLADE 50 40 ENABLED 5 CP BLADE 50 40 ENABLED 6 CORE BLADE 46 60 ENABLED 7 AP BLADE 74 250 ENABLED 8 AP BLADE 74 250 ENABLED Total DC Power Consumption 1199 watts Total AC Power Consumption 1332 watts AC 90 efficiency 4546 BTU Power Efficiency 1 04 wat...

Page 958: ...a trap The sender cannot determine if the trap was received However an SNMP manager that receives an inform request acknowledges the message with an SNMP response protocol data unit PDU If the manager does not receive an inform request it does not send a response If the sender never receives a response the inform request can be sent again For this reason informs are more likely to reach their inte...

Page 959: ...ted with each trap recipient IP address When 0 is configured as a trap port traps can be received at the default port 162 snmpv3 Selects SNMPv3 related configuration parameters These parameters include the user name authentication protocol and password the privacy protocol and password the SNMPv3 trap recipient s IP address its associated user index and trap severity level When 0 is configured as ...

Page 960: ...en an event occurs and its severity level is at or below the set value the Event Trap traps swEventTrap connUnitEventTrap and swFabricWatchTrap are sent to configured trap recipients By default this value is set at 0 implying that no Event Trap is sent Possible values are 0 None 1 Critical 2 Error 3 Warning 4 Informational 5 Debug SNMPv3 Configuration Parameters Two user roles snmpadmin and snmpus...

Page 961: ... The connecting host is enabled to set each host subnet area to be read write or read only The closest match out of six entries is given access The ACL check is turned off when all six entries contain 0 0 0 0 The default values of all six entries are 0 0 0 0 For IPv6 subnets the format is specified by an IPv6 address followed by the number of fixed bits in the address MIB Capability Configuration ...

Page 962: ...iscsiTgtLoginFailure 3 0x8 Enabled ____________________________________________________ IF MIB 0x1 Enabled linkUpTrap 3 0x8 Enabled linkdownTrap 4 0x10 Enabled ____________________________________________________ BBD MIB 0x1 Enabled bdTrap 1 0x2 Enabled bdClearTrap 2 0x4 Enabled Use the show mibCapability option to display the traps configurable under each MIB For more information refer to the Fab...

Page 963: ...arameters sysDescr The system description The default value is Fibre Channel switch sysLocation The location of the system switch The default value is End User Premise The string must be at least 4 characters in length the maximum length is 255 characters sysContact The contact information for this system switch The default value is Field Support Refer to the definition of sysDescr sysLocation and...

Page 964: ...munity 3 private rw No trap recipient configured yet Community 4 public ro No trap recipient configured yet Community 5 common ro No trap recipient configured yet Community 6 FibreChannel ro No trap recipient configured yet To set the SNMPv1 configuration of a switch switch admin snmpConfig set snmpv1 SNMP community and trap recipient configuration Community rw Secret C0de Trap Recipient s IP addr...

Page 965: ...nd Fabric Watch alerts switch admin snmpconfig set mibCapability The SNMP Mib Trap Capability has been set to support SW TRAP yes y no n yes swFCPortScn yes y no n yes swEventTrap yes y no n yes Desired Serverity Level 1 critical 2 error 3 warning 4 informational 0 None 4 swFabricWatchTrap yes y no n yes Desired Serverity Level 1 critical 2 error 3 warning 4 informational 0 None 2 To enable the sw...

Page 966: ...angesTrap NO swIPv6ChangeTrap NO swPmgrEventTrap NO swFabricReconfigTrap NO swFabricSegmentTrap NO swExtTrap NO swStateChangeTrap NO swPortMoveTrap NO swBrcdGenericTrap NO To re enable all traps under the SW MIB category switch admin snmpconfig set mibCapability mib_name SW MIB bitmask 0xFFF Operation succeeded switch admin snmpconfig show mibCapability SW TRAP YES swFault YES swSensorScn YES swFC...

Page 967: ...rEventTrap NO swFabricReconfigTrap NO swFabricSegmentTrap NO swExtTrap NO swStateChangeTrap NO swPortMoveTrap NO swBrcdGenericTrap NO FA TRAP NO connUnitStatusChange NO connUnitDeletedTrap NO connUnitEventTrap NO connUnitSensorStatusChange NO connUnitPortStatusChange NO FICON TRAP NO linkRNIDDeviceRegistration NO linkRNIDDeviceDeRegistration NO linkLIRRListenerAdded NO linkLIRRListenerRemoved NO l...

Page 968: ...tion with informs disabled in the example the Engine ID in the user1 entry corresponds to the engine ID of the trap manager in Trap Entry 2 10 103 5 105 switch admin snmpconfig show snmpv3 SNMP Informs 1 ON SNMPv3 USM configuration User 1 rw snmpadmin1 Auth Protocol noAuth Priv Protocol noPriv Engine ID 00 00 00 00 00 00 00 00 00 User 2 rw snmpadmin2 Auth Protocol noAuth Priv Protocol noPriv Engin...

Page 969: ...oPriv 2 3DES 3 AES128 4 AES192 5 AES256 6 2 2 2 Engine ID 0 0 0 0 0 0 0 0 0 User rw snmpadmin3 Auth Protocol MD5 1 SHA 2 noAuth 3 1 3 3 Priv Protocol DES 1 noPriv 2 3DES 3 AES128 4 AES192 5 AES256 6 2 2 2 Engine ID 0 0 0 0 0 0 0 0 0 User ro snmpuser1 Auth Protocol MD5 1 SHA 2 noAuth 3 1 3 3 Priv Protocol DES 1 noPriv 2 3DES 3 AES128 4 AES192 5 AES256 6 2 2 2 Engine ID 0 0 0 0 0 0 0 0 0 User ro snm...

Page 970: ...Community 3 private rw No trap recipient configured yet Community 4 public ro No trap recipient configured yet SNMPv1 Disabled REFERENCES Refer to the following publications for further information on SNMP Fabric OS MIB Reference SW_v5_x mib Switch Management Information Switch Enterprise Specific Trap RFC1157 A Simple Network Management Protocol SNMPv1 RFC1213 Management information Base for Netw...

Page 971: ... used without operands the show option displays all Management Information Base MIB objects and associated traps that are supported in Fabric OS NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands...

Page 972: ...event trap sw event trap sw fabric reconfig trap sw fabric segment trap sw state trap sw port move trap sw brcd genric trap 002 FICON MIB link rnid device registration link rnid device deregistration link lirr listerner added link lirr listerner removed link rlir failure incident 003 FA MIB conn unit status change conn unit sensor status change conn unit port status change conn unit event trap 004...

Page 973: ... want to receive the traps switch admin snmpTraps block ALL switch admin snmpTraps unblock 17 switch admin snmpTraps unblock 18 To display the blocked port status switch admin snmpTraps show port Port 0 1 2 3 4 5 6 7 8 9 Blocked Port 10 11 12 13 14 15 16 17 18 19 Blocked Y Y Port 20 21 22 23 24 25 26 27 28 29 Blocked Port 30 31 32 33 34 35 36 37 38 39 Blocked SEE ALSO snmpConfig ...

Page 974: ...nd in the appropriate order In this manner the test can verify the entire path to the remote switch as well as the proper in order delivery operation of any trunk groups present The switch remains in normal operation while this test is running However some performance degradation may occur due to the ISLs being saturated with test frames For this reason use caution when running this test on live f...

Page 975: ...mmand Availability for details OPERANDS This command has the following operands nmegs count Specifies the number of frames to send in millions The test progresses until the specified number of frames has been transmitted on each port The default value is 10 million frames This command only approximately counts the frames and the actual number of frames sent will be slightly larger particularly at ...

Page 976: ...AT_BADEOF ERR_STAT_BADOS ERR_STAT_C3DISC ERR_STAT_CRC ERR_STAT_ENCIN ERR_STAT_ENCOUT ERR_STAT_TRUNC FINISH_MSG_ERR INIT MBUF_STATE_ERR NO_SEGMENT PORT_ABSENT PORT_DIED PORT_ENABLE PORT_M2M PORT_STOPPED PORT_WRONG RXQ_RAM_PERR STATS STATS_C3FRX STATS_FRX STATS_FTX TIMEOUT XMIT EXAMPLES To test cascading ISLs switch admin spinfab ports 1 0 1 2 spinfab running spinfab Completed 11 megs status passed ...

Page 977: ...decrypts the message and the login succeeds Use the sshUtil command to do the following Configure a user to perform public key authentication and to manage keys on a switch Generate a private public key pair on the local switch Import a public key for a specified user from a remote host to the local switch Export the public key from the local switch to a remote host Delete the public keys associat...

Page 978: ...y was imported can perform public key authentication with the switch from the remote host on which the private key resides importpubkey prompts for the following input parameters Username Enter the user name for whom the key is imported IP Address Enter the IP address for the remote host IPv4 and IPv6 addresses are supported remote directory Enter the path where the public key is stored on the rem...

Page 979: ...tions from the switch to a remote host This option can only be performed by a configured user The successfully exported public key must be appended to the authorized_keys file on the remote host Use the cat ssh outgoing pub ssh authorized_keys command to append the file exportpubkey prompts for IP Address remote directory login name and password Refer to importpubkey for a description of these par...

Page 980: ... DYPplWuFouOmTcmuNvpTnd yoZ u3C lAu930HLTmhfxeke NWRIdj2MJS8yTf30a0u4bf9MSNB8Pt453P 7VHHxNBYsh Z Dv1hfcTeb 0s53bdf7jyYSUdj1k w sNTaz0DCs0 rimo4l2NAAAAFQDCuHKRctSH D8PRYu5Ee1yWCQKT wAAAIAo AMvr1ooq0JVXmXfd0VKcC7AImzFYgRa FOxZBe4JDkCAXztFk5wnAFy UbyTWEoC955mkYGqZRydMrSNM 9wLCAf2DTxXxuHFujA1REL5NGdZqRWo2Sk5HLkYQQYM1w9r9vfK QnFH3wYsnHV2sq7 tyRlXfwE416ee chdwWVpmjgAAAIEAqxcaE1vY4o cBq1Py62lPaZTcfOHS3jj...

Page 981: ... Enter remote directory username ssh Enter login name username Password public key out_going pub is exported successfully 3 Append the public key to the authorized_keys file on the remote host username remotehost cat ssh outgoing pub ssh authorized_keys To delete the private key on a switch switch username sshutil delprivkey private key is deleted successfully SEE ALSO None ...

Page 982: ...t may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS The following are optional slot slot Specifies the slot on which to operate If this option is not specified the default slot is assumed The default slot is 0 and designed to operate on fixed port count products if use_bports sets with nonzero value uports itemlist Specifies the li...

Page 983: ...o Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operand ports itemlist Terminates the test on the specified ports this operand is optional if omitted the test is terminated on all ports Refer to the itemList help page for more information EXAMPLES T...

Page 984: ...hout operands the command prints the usage NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands disable Disables the FFDC enable Enables the FFDC show Displays the FFDC configuration parameters EXA...

Page 985: ...p parameters The following operands are optional If the s option is specified without further operands the command interactively prompts for these parameters h host Specifies the host Provide an IP address or a server name IPv4 and IPv6 addresses are supported To specify the host by name a DNS entry must exist for the server u username Specifies the user name The user name must be less than 48 cha...

Page 986: ...tp Host IP Addr 1080 8 800 200C 417A User name admin Remote Dir support Auto Upload protocol sftp Auto FTP Off To set FTP parameters interactively switch admin supportftp s Host IP Addr 1080 8 800 200C 417A 192 168 67 126 User Name admin admin Password password Remote Dir support Auto upload protocol ftp scp Auto file transfer parameters changed To set the time interval at which the FTP server con...

Page 987: ... support file a tar gz file is generated from each slot This command accepts IPv4 and IPv6 addresses If the configured IP address is in IPv6 format the RAS auto file transfer and event notification to syslog will not work in the case where the Fabric OS version is downgraded You must reconfigure auto file transfer and syslog with IPv4 IP addresses In a Virtual Fabric environment supportSave saves ...

Page 988: ...e not required for each attempted transfer by the supportSave command Failure to configure the service correctly may result in significant delays in obtaining transferred output from the supportSave command When using secure copy SCP supportSave may create a directory specified by the d option if it does not already exist and the parent directory has the appropriate permissions Use of FTP requires...

Page 989: ...on for chassis HL51 module SSHOW_FABRIC output truncated To collect support information on a Brocade 5100 and save it to an attached USB device timeout values are doubled switch admin supportsave U d mysupportsave t 2 This command collects RASLOG TRACE supportShow core file FFDC data and then transfer them to a FTP SCP SFTP server or a USB device This operation can take several minutes NOTE suppor...

Page 990: ...rt information for chassis ras2 module FABRIC Saving support information for chassis ras2 module CORE_FFDC Saving support information for chassis ras2 slot 4 slot 4 support file transfer done Saving support information for chassis ras2 slot 12 slot 12 support file transfer done Saving support information for chassis ras2 module DIAG Saving support information for chassis ras2 module RTE Saving sup...

Page 991: ...next to the FCIP command group SupportShow executes commands in the following command groups Use supportShowCfgenable or supportShowCfgDisable to modify the settings for each group os OS group commands enabled by default exception Exception group commands enabled by default port Port group commands enabled by default fabric Fabric group commands enabled by default services Service group commands e...

Page 992: ...s the following operands slot On bladed systems only specifies a slot number followed by a slash port1 por2 Specifies a port or a range of ports for which to display supportShow information this operand is optional if omitted the command displays information for all ports lines Specifies the number of lines for the portLogDump output This parameter is valid only with the slot port parameters EXAMP...

Page 993: ...2009 portlogdump CURRENT CONTEXT 0 128 portlogdump time task event port cmd args Sat Dec 5 23 54 37 2009 23 54 37 560 FCPH read 56 16 02fffc23 00fffc19 bb000000 00000000 04 3401bb 23 54 37 560 FCPH seq 56 10 20290000 043401bb 00000722 0000001c 00 000000 23 54 37 560 msd0 ctin 56 fa 0001f007 00000000 23 54 37 561 msd0 ctout 56 fa 00018001 0009f300 output truncated SEE ALSO supportFtp supportSave su...

Page 994: ... of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands os Disables the OS group commands exception Disables the exception group commands port Disables the port group commands fabric Disables the fabric group commands s...

Page 995: ...l Disables the DCE group commands crypto Disables the encryption group commands fcip Disables the FCIP group commands Supported only on the Brocade 7800 FX8 24 and FR4 18i EXAMPLES To disable the OS group of commands under the supportShow command switch admin supportshowcfgdisable os Config update Succeeded SEE ALSO supportShow supportShowCfgEnable supportShowCfgShow ...

Page 996: ...s NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands os Enables the OS group commands exception Enables the exception group commands port Enables the port group commands fabric Enables the fabric...

Page 997: ...isables the DCE group commands crypto Enables the encryption group commands fcip Enables the FCIP group commands Supported only on the Brocade 7800 FX8 24 and FR4 18i platforms EXAMPLES To enable a group of commands under the supportShow command switch admin supportshowcfgenable os Config update Succeeded SEE ALSO supportShow supportShowCfgDisable supportShowCfgShow ...

Page 998: ...trictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To display command groups configured for data collection on the Brocade 6510 switch admin supportshowcfgshow os enabled exception enabled port enabled fabric enabled services enabled security enabled network enabled portlog enabled system enabled extend ...

Page 999: ...abric OS Command Reference 965 53 1001764 01 supportShowCfgShow 22 iswitch enabled asic_db enabled fcip enabled ag enabled dce_hsl enabled SEE ALSO supportShow supportShowCfgDisable supportShowCfgEnable ...

Page 1000: ... port for example is suppressed and only the beaconing pattern is shown However if diagnostic frame based tests such as portLoopbackTest are executed two patterns are interleaved The diagnostic test flickers the LEDs green and the beaconing mode runs the LEDs amber at the same time Use the switchShow command to display the status of beaconing NOTES The execution of this command is subject to Virtu...

Page 1001: ...hing amber You can temporarily enable a persistently disabled switch with the switchEnable command A temporarily enabled switch remains disabled after a reboot NOTES Performance Monitoring cannot be added to any port on a persistently disabled switch The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Comma...

Page 1002: ... If another switch assumes the principal role then this switch becomes a subordinate switch and accepts a domain ID from the principal Refer to the FC SW specification for a complete description of this process As each port is enabled the front panel LEDs change from slow flashing amber to green for online ports or to nonflashing amber for ports that do not initialize Disconnected ports remain unl...

Page 1003: ...d command Use the portShow command to display actual port speed settings Use the portCfgShow command to display user configured speed settings NOTES This configuration cannot be set on VE_Ports or VEX_Ports Speed configuration is not applicable to FCoE ports The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric ...

Page 1004: ...nd you disable trunking on the switch after you removed the blade the blade ports will come online with trunking enabled after you reinsert the blade To avoid potentially disruptive behavior reapply the trunking configuration Trunking on Inter Chassis Link ICL ports is always enabled and cannot be turned off by this command Disabling trunking fails if a Trunk Area TA is enabled on the port Use the...

Page 1005: ...o be disabled generate an error message if invoked while the switch is enabled It is not necessary to disable the switch before rebooting or powering off When this command is executed on a logical switch only the ports allocated to the logical are disabled To disable the entire chassis use the chassisDisable command NOTES The execution of this command is subject to Virtual Fabric or Admin Domain r...

Page 1006: ...l role then the re enabled switch becomes a subordinate switch and accepts a domain ID from the principal As each port is enabled the front panel LED changes to green for online ports or to amber for uninitialized ports Disconnected ports remain unlit When this command is executed on a logical switch only the ports allocated to the logical switch are enabled To enable the entire chassis use the ch...

Page 1007: ...CN to be issued Refer to the FC FLA specification for a description of RSCNs NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operand name Specifies the name for the switch A switch name can include up ...

Page 1008: ... Online Temporary The switch remains in this state until you issue the switchcfgPersistentEnable command switchMode Switch operation mode Access Gateway if AG is enabled switchRole Switch role Principal Subordinate or Disabled switchDomain Switch domain ID 1 to 239 switchId Switch embedded port D_ID switchWwn Switch world wide name WWN switchBeacon Switch beaconing state On or Off zoning The name ...

Page 1009: ...ia types include the following No module present Applicable to all port types cu Displays when the copper default GbE port ge0 or ge1 is active refer to portCfgGeMediaType for more information If the optical GbE port is active and an SFP is installed copper or optical id is displayed If nothing is installed on the optical port the Media field shows The cu field also displays for interchassis links...

Page 1010: ...is state is not applicable to Condor 3 based interchassis link ICL ports No_SigDet No signal is detected on the port For Condor 3 based interchassis link ICL ports this state replaces the No_Light indicator It indicates that a quad small form factor pluggable QSFP has been installed but is not connected with a cable No_Sync The module is receiving light but is out of sync In_Sync The module is rec...

Page 1011: ...e The port is disabled and in Ficon Server Management mode Disabled No area available for PID assignment The port is disabled because a PID could not be assigned for the stated reason Disabled persistent This port has been disabled with the portCfgPersistentDisable command Disabled Persistently disabled port This port has been disabled for unspecified reasons Bypassed The port is bypassed loop onl...

Page 1012: ...nfiguration when fmsmode was enabled See the ficonCupSet help page for more information Fabric ID conflict Two different fabrics have been assigned the same fabric ID Applicable only to EX_Ports and Logical Fabric environments Fabric ID oversubscribed One fabric has been assigned two different fabric IDs EX_Ports only AoQ Application oriented QoS indicates that an F_Port or N_Port has negotiated a...

Page 1013: ...mber Blade Type Type of blade for example Core blade or AP blade Refer to the slotShow command for a listing of supported blade types ID A numeric blade ID that specifies the blade type Refer to the slotShow command for a listing of supported blade IDs Status Enabled or disabled NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer...

Page 1014: ... corresponds to the physical QSFP number that can be found on the front of each Core Blade A double dash indicates that no QSFP is present EXAMPLES To display the port count switch admin switchshow portcount FC ports 198 GE ports 12 To display GbE ports with iSCSI sessions switch admin switchshow iscsi Ports of Slot 1 ge0 ge1 ge2 ge3 ge4 ge5 ge6 ge7 Sessions 0 0 0 0 0 0 0 0 To display a QoS capabl...

Page 1015: ... N Port 10 00 00 05 1e 43 e8 02 0x690100 Trunk master AoQ 33 33 N8 No_Module FC 34 34 id N8 Online FC N Port 10 00 00 05 1e 43 e8 02 0x690100 Trunk port master is Port 32 AoQ 35 35 N8 No_Module FC 36 36 N8 No_Module FC 37 37 N8 No_Module FC 38 38 N8 No_Module FC 39 39 N8 No_Module FC To display switch information on a Virtual Fabrics enabled switch with an assigned fabric name switch admin switchs...

Page 1016: ... State Proto 0 0 850000 id N8 Online FC E Port 10 00 00 05 1e 92 de 00 pluto145 upstream Trunk master 1 1 850100 id N8 Online FC E Port Trunk port master is Port 0 2 2 850200 id N8 Online FC E Port Trunk port master is Port 0 3 3 850300 id N8 Online FC E Port Trunk port master is Port 0 4 4 850400 id N8 Online FC E Port Trunk port master is Port 0 5 5 850500 id N8 Online FC E Port Trunk port maste...

Page 1017: ...nline switchMode Native switchRole Subordinate switchDomain 60 switchId fffc3c switchWwn 10 00 00 05 1e 40 68 78 zoning ON WB_DEFAULT_CFG_LSAN switchBeacon OFF FC Router OFF Allow XISL Use OFF LS Attributes FID 128 Base Switch No Default Switch Yes Address Mode 0 Index Slot Port QSFP Address Media Speed State Proto 812 3 60 3c2cc0 N8 No_Module FC 813 3 61 3c2dc0 N8 No_Module FC 814 3 62 3c2ec0 N8 ...

Page 1018: ...4 3 16G No_Module FC 1155 5 35 3 16G No_Module FC 1156 5 36 3 16G No_Module FC 1157 5 37 3 16G No_Module FC 1158 5 38 11 16G No_Module FC 1159 5 39 11 16G No_Module FC 1160 5 40 10 16G No_Module FC 1161 5 41 10 16G No_Module FC 1162 5 42 2 16G No_Module FC 1163 5 43 2 16G No_Module FC 1164 5 44 2 16G No_Module FC 1165 5 45 2 16G No_Module FC 1166 5 46 10 16G No_Module FC 1167 5 47 10 16G No_Module...

Page 1019: ...C E Port 10 00 00 05 1e 39 f0 ca ras040 Trunk master 445 8 29 4 id 16G Online FC E Port 10 00 00 05 1e 39 f0 ca ras040 Trunk master 446 8 30 12 id 16G No_SigDet FC 447 8 31 12 id 16G No_SigDet FC 1184 8 32 11 16G No_Module FC 1185 8 33 11 16G No_Module FC 1186 8 34 3 16G No_Module FC 1187 8 35 3 16G No_Module FC 1188 8 36 3 16G No_Module FC 1189 8 37 3 16G No_Module FC 1190 8 38 11 16G No_Module F...

Page 1020: ...s an SFP installed copper or optical ge0 cu 1G No_Sync FCIP Copper ge1 id 1G No_Light FCIP ge2 1G No_Module FCIP ge3 1G No_Module FCIP ge4 id 1G Online FCIP ge5 1G No_Module FCIP This example shows switchshow output for a Brocade 5100 Port 31 has an SFP installed Nothing is installed on Port 32 31 31 421f00 id N4 In_Sync FC Disabled 32 32 422000 N8 No_Module FC Disabled The sfpShow output for the ...

Page 1021: ...ds both default and user defined of MarginalPorts FaultyPorts ErrorPorts and MissingSFPs are calculated as a percentage of the current number of physical ports present in the switch at any given moment For example the input value of 25 00 indicates 25 of all physical ports VE_Ports and FCoE Ports are excluded from the calculation The percentage supports decimal values of up to two decimal points T...

Page 1022: ...t the value 0 for a parameter means that it is NOT used in the calculation In addition if the range of settable values in the prompt is 0 0 the policy parameter is NOT applicable to the switch Simply hit the Return key The minimum number of Bad PowerSupplies contributing to DOWN status 0 2 2 Bad PowerSupplies contributing to MARGINAL status 0 2 1 Bad Temperatures contributing to DOWN status 0 4 2 ...

Page 1023: ...Temperatures contributing to MARGINAL status 0 32 0 Bad Fans contributing to DOWN status 0 3 1 Bad Fans contributing to MARGINAL status 0 3 0 Down WWN contributing to DOWN status 0 2 0 Down WWN contributing to MARGINAL status 0 2 0 Down CP contributing to DOWN status 0 2 0 Down CP contributing to MARGINAL status 0 2 0 Down Blade contributing to DOWN status 0 8 0 Down Blade contributing to MARGINAL...

Page 1024: ...at contributes to the DOWN status and the third column indicates the minimum number that contributes to the MARGINAL status The policy parameters are set by the switchStatusPolicySet command Not all policies are supported on all platforms Refer to the switchStatusPolicySet help page for more information NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions t...

Page 1025: ...d Blades bladed systems only Flash Marginal ports Faulty ports Error Ports Status values are HEALTHY MARGINAL or DOWN depending on whether thresholds established by switchStatusPolicySet have been exceeded The overall status is based on the most severe status of all contributors Refer to switchStatusPolicySet for details on the calculation of contributors and overall switch status NOTES The execut...

Page 1026: ...3 12 2011 12 57 01 PM Switch Name VF128_CDCX16_114057 IP address 10 20 114 57 SwitchState HEALTHY Duration 44 16 Power supplies monitor HEALTHY Temperatures monitor HEALTHY Fans monitor HEALTHY WWN servers monitor HEALTHY CP monitor HEALTHY Blades monitor HEALTHY Core Blades monitor HEALTHY Flash monitor HEALTHY Marginal ports monitor HEALTHY Faulty ports monitor HEALTHY Missing SFPs monitor HEALT...

Page 1027: ...e current time and the amount of time that the switch has been operational NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To view the uptime for the switch switch user switchuptime 9 50pm up for 20 mins SEE ALSO None ...

Page 1028: ... The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details This command can be executed on both active and standby CPs This command does not support High Availability HA OPERANDS This command has the following operands If executed without operands the comma...

Page 1029: ...is command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands l level Specifies the syslog facility Valid levels are 0 through 7 The default is 7 This operand is optional if omitted the current facility is displayed 0 LOG_LOCAL0 1 ...

Page 1030: ...mand must be executed for each server NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands ip_address Specifies the IP address of the server running syslogd in IPv4 or IPv6 format EXAMPLES To add a...

Page 1031: ...slog server configuration NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operand ip_address Specifies the IP address of the server running syslogd EXAMPLES To remove the IP address 1080 8 800 200C 417...

Page 1032: ...onfiguration database by IP address IPv4 and IPv6 addresses are supported NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To display all syslog daemon IP addresses configured on a switch switch admin syslogdipshow sysl...

Page 1033: ...reporting for the environment and resource classes Environment thresholds enable temperature monitoring and resource thresholds enable monitoring of flash memory This command follows a transaction model Configuration changes are saved persistently to nonvolatile storage but the changes do not take effect until you execute apply The apply option allows you to toggle between default settings and you...

Page 1034: ...ass resource Monitors the resource class area area Specifies the area that can be configured for this class This operand is optional with the show option it is required with all configuration options Valid areas include the following temp Specifies the temperature area for the environment class This area is valid only with the environment class flash Specifies the flash memory area for the resourc...

Page 1035: ... custom and default settings The specified configuration takes effect upon execution of this command When you select custom the saved configuration becomes effective cancel Cancels a nonpersistent configurations This command effectively undoes the nosave operation without reboot You must always specify a class and area when you apply or cancel a configuration Thresholds and alarm levels are option...

Page 1036: ...CPU monitoring specify a value in the 1 to 100 range When CPU usage exceeds the limit a Fabric Watch alert is triggered The default CPU limit 75 When used to configure memory monitoring the limit value must be greater than the low limit and smaller than the high limit When the limit is exceeded Fabric Watch sends out a RASlog WARNING message When usage returns below the limit Fabric Watch sends a ...

Page 1037: ...ion email lowthreshold value 32 trigger below action email To apply the custom thresholds for temperature switch admin sysmonitor apply env area temp action_level cust thresh_level cust To cancel the previously configured thresholds for temperature switch admin sysmonitor cancel env area temp action_level cust thresh_level cust To display the Fabric Watch configuration for temperature switch admin...

Page 1038: ...hold value 100 To apply the custom thresholds for flash memory switch admin sysmonitor apply resource area flash thresh_level cust To display the Fabric Watch configuration for flash memory switch admin sysmonitor show resource Class RESOURCE Area FLASH ThLevel Cust ActLevel Cust High Custom TimeBase None Value 100 Trigger Above Action Raslog SNMP Trigger Below Action Raslog Default TimeBase None ...

Page 1039: ...itoring switch admin sysmonitor config mem poll 10 retry 3 limit 60 action snmp raslog high_limit 70 low_limit 40 To display the current memory usage and configuration switch admin sysmonitor show mem Showing Memory Usage Used Memory 192020k 25 Total Memory 768080k Free Memory 576060k Used Memory Limit 60 Low Used Memory Limit 40 High Used Memory Limit 70 Polling Interval 60 seconds No Of Retries ...

Page 1040: ...endix A Command Availability for details OPERANDS None EXAMPLES To perform a system shutdown on a standalone platform switch admin sysshutdown This command will shutdown the operating systems on your switch You are required to power cycle the switch in order to restore operation Are you sure you want to shutdown the switch y n y Broadcast message from root ttyS0 Mon Sep 12 17 52 12 2005 The system...

Page 1041: ...tDown 22 To attempt a system shutdown from the standby CP not supported switch admin sysshutdown Shut down the whole system is not support from the standby CP For shut down the whole system please run the sysshutdown from the active CP SEE ALSO haDisable ...

Page 1042: ...e and Fahrenheit NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details Refer to the hardware reference manual for your switch to determine the normal temperature range OPERANDS None EXAMPLES To display temperature and status sensors switch user te...

Page 1043: ...o display the configuration If configured areas exceed the currently effective threshold settings the Fabric Watch daemon can take one or more of the following actions Send an SNMP message Log a RASlog message Send an E mail alert Locks the port log only applicable to SFP state change area and FABRIC class The thConfig command follows a transaction model When you configure thresholds and actions w...

Page 1044: ...ith the sfptype option on Condor 3 based platforms thresholds configured for the SFP class apply to 16G SFPs 10G SFPs and 16G QSFPs Valid areas for the SFP class include the following TEMP Monitors the physical temperature of the SFP in degrees Celsius For 16G QSFPs Fabric Watch monitors temperature only on the first QSFP port that is available on the logical switch RXP Measures Receive Power for ...

Page 1045: ...violations LV Tracks the number of login violations IC Tracks the number of invalid certificates TS Tracks the number of times the time server is out of sync FF Tracks the number of Fibre Channel link access protocol FLAP violations NF Tracks the number of times the switch has lost contact with the primary FCS ISB Tracks the number of times the switch encounters an incompatible security database I...

Page 1046: ...rval between two samples to be compared Valid intervals include the following day Samples are compared once a day hour Samples are compared once every hour minute Samples are compared once every minute none Samples are not compared sfptype sfp_type Configures and manages thresholds and alerts for 10G SFPs 16G SFPs and 16G QSFPs Fabric Watch applies thresholds based on the serial numbers of the SFP...

Page 1047: ...revents the configuration changes from being saved persistently This option allows you to make and view changes without overwriting the saved configuration When you use set with the nosave option and the switch reboots your changes will be lost apply Applies the custom or default configuration for thresholds actions or both This command allows you to toggle between custom and default settings The ...

Page 1048: ...ecifies the class area area area all Specifies the area You can either specify one or more areas separated by a comma or you can specify all to indicate all areas port port_list all Specifies one or more ports or all ports The port_list operand supports one of the following values A single port number preceded by the slot number on bladed systems A set of comma separated port numbers preceded by t...

Page 1049: ... display the Fabric Watch configuration for the QSFP temperature on a DCX 8510 8 switch admin thconfig show sfp area temp sfptype qsfp Class SFP SFP TYPE QSFP Area TEMP ThLevel Def ActLevel Def High Custom TimeBase None Value 85 Trigger Above Action Raslog Trigger Below Action Raslog Default TimeBase None Value 85 Trigger Above Action Raslog Trigger Below Action Raslog Low Custom TimeBase None Val...

Page 1050: ...Continue QSFP SFP TEMP 000392 0 Info Continue QSFP SFP TEMP 000397 0 Info Continue QSFP SFP TEMP 000400 0 Info Continue QSFP SFP TEMP 000407 0 Info Continue QSFP SFP TEMP 000408 0 Info Continue QSFP SFP TEMP 000412 0 Info Continue QSFP SFP TEMP 000419 0 Info Continue QSFP SFP TEMP 000420 0 Info Continue QSFP SFP TEMP 000425 0 Info Continue QSFP SFP TEMP 000431 0 Info Continue QSFP SFP TEMP 000435 ...

Page 1051: ...ix A Command Availability for details OPERANDS This command has the following operands enable brcdsfp Enables Fabric Watch threshold monitoring for 10G and 16G SFPs and for 16G QSFPs The feature is by default disabled disable brcdsfp Disables Fabric Watch threshold monitoring for 10G and 16G SFPs and for 16G QSFPs show Displays the current configuration help Displays the command usage EXAMPLES To ...

Page 1052: ...s effect with the next logins NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operand timeval Specify the number of minutes for the Telnet timeout value Valid values are 1 to 99 999 or 0 to disable log...

Page 1053: ...s for local translate domains are not displayed If there are two switches in the Backbone and the edge fabric is directly connected to both of those switches topologyshow does not display the description of the translate domain associated with that edge fabric In this case the translate domain is considered local to both of the switches in the backbone If there is only one switch in the backbone n...

Page 1054: ... Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS The following operand is optional domain Specify the destination domain for which to display the topology information EXAMPLES To display the topology on a single switch domain is local details are not displayed switch user topologyshow 1 domains in the fabric Local Domain ID 97 When executed from an edge fabric top...

Page 1055: ...ive switches The fabric has five domains but details are only shown for the three remote domains not for the two local translate domains switch user topologyshow 5 domains in the fabric Local Domain ID 2 Local Translate Domain 4 owned by port 24 Local Translate Domain 5 owned by port 23 33 Domain 1 Metric 500 Name pengsaturn104 Path Count 1 Hops 1 Out Port 0 In Ports 23 24 33 38 39 Total Bandwidth...

Page 1056: ... xxs Indicates the processor Values are cp0 cp1 bp0 bp1 dp0 or dp1 YYYYMMDDHHMMSS Indicates the trace dump time stamp year month day hour minute second type Indicates the tracedump type Valid types include BTRACE DTRACE and CTRACE new old Indicates a new or an old trace dump file dmp gz The compressed trace dump archive file extension For example the filename for a a new BFOS tracedump received fr...

Page 1057: ...hich a trace dump is generated If a slot is not supplied the trace dump is generated from the local slot This operand is optional EXAMPLES To initiate a background trace dump from slot 5 switch admin tracedump n s 5 To clear the status of a trace dump switch admin tracedump R trace dump removed To clear the content of the trace dump buffer switch admin tracedump c Cleared Trace Buffer contents SEE...

Page 1058: ...of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To display the track changes command help information switch admin trackchangeshelp trackchangeshelp Print track changes help info trackchangesset Configure track changes modes trackchangess...

Page 1059: ...tual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands mode Specify 1 to enable the track changes feature or specify 0 to disable the feature Track changes is disabled by default snmptrapmode Specify 1 to enable sending messages to the SNMP TRAP in add...

Page 1060: ...feature is enabled or disabled and whether SNMP traps are generated NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To display the track changes configuration switch admin trackchangesshow Track changes status ON Track...

Page 1061: ...r trunking might be disabled at remote port port port_id and port port_id cannot trunk please check link length to make sure difference is less than 400 m NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the followin...

Page 1062: ...skew The difference between the time it takes for traffic to travel over each ISL compared to the time it takes through the shortest ISL in the group plus the minimum deskew value The value is expressed in nanoseconds divided by 10 The firmware automatically sets the minimum deskew value for the shortest ISL which is 15 Master Displays whether this trunking port connection is the master port conne...

Page 1063: ...ter backbone fabric interlinking several edge fabrics see the EX_Port with WWN 10 00 00 05 1e 35 b3 03 and the E_Port with WWN 10 00 00 05 1e 37 12 13 in the output below switch admin trunkshow 4 49 0 10 00 00 05 1e 35 b3 03 4 deskew 16 MASTER 54 2 10 00 00 05 1e 35 b3 03 4 deskew 16 53 5 10 00 00 05 1e 35 b3 03 4 deskew 16 50 6 10 00 00 05 1e 35 b3 03 4 deskew 15 51 4 10 00 00 05 1e 35 b3 03 4 de...

Page 1064: ...rt 10 00 00 05 1e 37 12 13 SW4900_43 downstream Trunk master To display trunking information along with bandwidth throughput information switch admin trunkshow perf 1 43 0 10 00 00 05 1e 53 e3 8a 92 deskew 15 MASTER Tx Bandwidth 4 00Gbps Throughput 288 00bps 0 00 Rx Bandwidth 4 00Gbps Throughput 320 00bps 0 00 Tx Rx Bandwidth 8 00Gbps Throughput 608 00bps 0 00 2 58 66 10 00 00 05 1e 4f eb 00 65 de...

Page 1065: ... Use this command without parameters to display the active NTP server and the configured NTP server list Specify the ipaddr operands to set the clock server IP addresses and enable fabric wide clock synchronization with the specified clock server A value of LOCL may be specified as operand to set the clock server back to default Each ipaddr specified should be the IP address of an NTP server and s...

Page 1066: ... specified IP address switch admin tsclockserver 123 123 123 123 Updating Clock Server configuration done switch admin tsclockserver 123 123 123 123 To configure multiple NTP servers switch admin tsclockserver 12 134 125 24 12 234 87 01 Updating Clock Server configuration done SEE ALSO date ...

Page 1067: ...h is in offset mode old with zero offsets that is time is displayed in GMT Use tsTimeZone timezonename to change the offset format to the timezone name format When executed without parameters this command displays the current time zone configuration in the format in which it was set Negative hour offset values mean that the local time is behind GMT for example 8 0 is GMT 08 00 Positive hour offset...

Page 1068: ...e current timezone to the zone to Pacific Time using the interactive command mode switch admin tsTimeZone interactive Please identify a location so that time zone rules can be set correctly Please select a continent or ocean 1 Africa 2 Americas 3 Antarctica 4 Arctic Ocean 5 Asia 6 Atlantic Ocean 7 Australia 8 Europe 9 Indian Ocean 10 Pacific Ocean 11 none I want to specify the time zone using the ...

Page 1069: ...entral Time North Dakota Oliver County 14 Mountain Time 15 Mountain Time south Idaho east Oregon 16 Mountain Time Navajo 17 Mountain Standard Time Arizona 18 Pacific Time 19 Alaska Time 20 Alaska Time Alaska panhandle 21 Alaska Time Alaska panhandle neck 22 Alaska Time west Alaska 23 Aleutian Islands 24 Hawaii Enter number or control D to quit 18 The following information has been given United Sta...

Page 1070: ... Appendix A for a table that correlates ASIC type with switch models NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details The switch must be disabled before you can run this diagnostics OPERANDS This command has the following optional operands sl...

Page 1071: ...0 seconds the time is displayed in seconds For times greater than or equal to 60 seconds the time is displayed in minutes The output format adjusts accordingly NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS None EXAMPLES To display...

Page 1072: ...utes load sharing may be affected The switch attempts to optimize load sharing but if too many routes are statically configured to use the same output port a fair load sharing may not be achievable To prevent routing loops static route requests involving non minimum cost paths are not enforced NOTES Static route configuration is not supported on the Brocade 300 5100 5300 and DCX platforms The exec...

Page 1073: ...from static to dynamic NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands in_area Specify the input port of the static route to remove in_area can be either an F_Port or an E_Port domain Specify ...

Page 1074: ...ming frame is to be forwarded Except for the cases in which you perform a port swap or enable extended edge PID PID Format 2 on a switch the value is equal to the port index field displayed by the switchShow command For port swap operations the value is equal to the switch port field displayed by the portSwapShow command Refer to Fabric OS Administrator s Guide for more information regarding the e...

Page 1075: ...ing information for all input ports in the switch domain Specify a remote domain in the fabric for which routing information is to be displayed This operand is optional if omitted the routing information for all domains in the fabric is displayed EXAMPLES To display the routing information of all the active ports switch admin urouteshow Local Domain ID 3 In Port Domain Out Port Metric Hops Flags N...

Page 1076: ...Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details This command is available only on the Active CP OPERANDS This command has the following operands e enable Enables the USB device The USB device must be enabled before the list and remove functions are available d disable Disables an enabled USB device This command prevents access to the device until it is e...

Page 1077: ...034 105MB 2010 Aug 23 06 11 config 0B 2010 Aug 15 15 13 firmware 380MB 2010 Aug 15 15 13 FW_v6 4 0 380MB 2010 Aug 15 15 13 Available space on usbstorage 74 To remove a firmware target from the firmware application area switch admin usbstorage r firmware FW_v6 0 0 To disable an attached USB device switch admin usbstorage d USB storage disable SEE ALSO supportSave firmwareDownload configUpload confi...

Page 1078: ...and options and behavior depend on your environment In an Admin Domain enabled environment you can configure the account s username its role and the Admin Domains that the account may access An account is assigned a single role An account can access multiple Admin Domains but only one Admin Domain at a time New accounts created take on the role specified during account creation In a Virtual Fabric...

Page 1079: ... AD management BasicSwitchAdmin Administrative use with a subset of admin level commands mostly for monitoring with limited switch local access Admin All administrative commands SecurityAdmin All switch security and user management functions NOTES The userConfig command operates on the switch local user database only regardless of whether the switch is configured to use RADIUS or LDAP authenticati...

Page 1080: ... or the home LF of any default account You cannot change the role the AD or LF permissions or the description of accounts at the same or a higher authorization level You cannot change the role the AD or LF permissions or the home AD or home Logical Fabric of your own account No account can disable itself AD or LF permissions must be a subset of the respective AD or LF permissions of the account th...

Page 1081: ...s or both for example a 0 9 10 15 244 l LF_ID_list Specifies the Virtual Fabrics the user is authorized to access The LFs in LF_ID_list and the existing LF permissions for username must be a subset of the LF permissions of the account that executes this command This operand is required with the add option It is optional with the change option c chassis_role Specifies the account s access permissio...

Page 1082: ... current home AD is deleted the new home AD is set to the lowest numbered AD in the user s AD permissions The existing AD permission for username and the AD_ID_list must be a subset of the AD permissions of the account executing this command a AD_ID_list Specifies the AD IDs to be added or deleted Specify a range 1 5 or a list of AD_IDs separated by comma 1 2 3 or a combination of both 1 5 7 addlf...

Page 1083: ...t You cannot delete your own account AD_ID_list or LF_ID list and associated AD or LF permissions for username must be a subset of the AD or LF permissions of the account that executes the userConfig delete command help Displays the command usage In an LF enabled environment LF specific options are displayed In an AD enabled environment AD specific options are displayed EXAMPLES A The following ex...

Page 1084: ...st New home AD is set to 0 switch admin userConfig deletead bob a 128 h 0 B The following examples illustrate how to create and manage user accounts in an LF enabled environment To create a new account named test with admin role and admin chassis permissions in the LF member list 1 10 switch admin userconfig add test l 1 10 r admin c admin Setting initial password for test Enter new password Re ty...

Page 1085: ...s Role user Home Context 4 To remove chassis permissions from the test account for the LFs 1 3 switch admin userconfig deletelf test l 1 3 c Broadcast message from root ttyS0 Sat Jun 14 01 10 02 2008 Security Policy Password or Account Attribute Change test will be logged out LFs chassis role for account test has been successfully deleted To display information for all accounts with admin privileg...

Page 1086: ...unning in switch Flash The build date of firmware stored in flash proms BootProm The version of the firmware stored in the boot PROM Usually the Made on and Flash dates are the same because the switch starts running flash firmware at power on However in the time period between firmwareDownload and the next reboot the dates can differ OPERANDS None EXAMPLES To display the firmware version informati...

Page 1087: ...hat may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operands sn On enterprise class platforms this operand displays the chassis factory serial number following the WWN On standalone platforms it displays the factory serial number This operand is optional if omitted this command displays only the WWN...

Page 1088: ...e 5100 switch admin wwn 10 00 00 05 1e 7a 7a 00 To display the WWN and factory serial number switch admin wwn sn WWN 10 00 00 05 1e 82 3c 2a SN ALM0602E003 switch admin chassisshow grep ALM0602E003 Factory Serial Num ALM0602E003 SEE ALSO chassisShow fabricShow licenseIdShow switchShow ...

Page 1089: ... provides a show option that displays the currently bound address for all WWNs Alternately you can use the findPID option to display the PID currently bound to a specified WWN NOTES Dynamic Area Mode and WWN Based persistent PID must be enabled on the switch before you can assign an address with this command Refer to configure for more information This command is supported only on the Brocade DCX ...

Page 1090: ...8 0x12 6 10 00 00 06 2b 0f 70 14 0x401 29 0x12 7 10 00 00 06 2b 0f 70 15 0x505 46 0x12 8 10 00 00 06 2b 0f 70 16 0x402 33 0x12 9 10 00 00 06 2b 0f 70 17 0x406 47 0x12 10 10 00 00 06 2b 0f 72 20 0x403 30 0x12 11 10 00 00 06 2b 0f 72 21 0x501 36 0x12 12 10 00 00 06 2b 0f 72 23 0x502 34 0x12 13 10 00 00 06 2b 0f 6e 30 0x301 35 0x12 14 10 00 00 06 2b 0f 6e 31 0x102 42 0x12 15 10 00 00 06 2b 0f 6e 32 0...

Page 1091: ...y expunge and validate options to perform specific zoning operations These commands follow a batched transaction model 2 Manage Traffic Isolation TI Zones Use the create add remove delete activate deactivate and show options to manage Traffic Isolation Zones TI zones control the flow of interswitch traffic by provisioning certain E_Ports to carry only traffic flowing from a specific set of source ...

Page 1092: ... and target The RD Zone is part of the defined zone configuration and does not appear in the effective zone configuration Use cfgSave to save the RD zone changes to the defined configuration Use cfgShow to display the RD zones When you create the first RD zone two additional zone objects are created automatically A base zone red_______base and a zone configuration r_e_d_i_r_c__fg These additional ...

Page 1093: ...f zone object references can trigger the removal of zones not specified in the command For example removing the last zone member from a zone deletes the zone and may trigger a recursive deletion of other zones The following operand is required zone_object Specifies a zone object A zone object can be a zone member zone alias or a zone The zone object must be enclosed in double quotation marks valid...

Page 1094: ...er enabled and the zone will be activated This operand is supported only with the create and add options Valid values for optlist include the following a Activates the specified zone d Deactivates the specified zone n Disables failover mode In non failover mode when the last interswitch link ISL of a TI Zone goes offline and there is an alternative ISL the alternative ISL is not used and the switc...

Page 1095: ... the specified zones The configured status reflects the latest change that may or may not have been activated The active status reflects the state that is activated by cfgEnable Without any specified name this command displays all TI zones in the defined configuration The following operand is optional ascending Displays the TI zone members in ascending order showTIerrors Analyzes real and potentia...

Page 1096: ...currently enforced zone database switch admin zonecreate z10 a10 switch admin zonecreate a10 1 2 switch admin zone validate Defined configuration zone a10 1 2 zone z10 a10 Effective configuration No Effective configuration No Access Invalid configuration Member does not exist Invalid usage of broadcast zone The reason for not being in the current enforcement table could be one of the following The...

Page 1097: ...nzone 1 1 20 01 00 05 1e 01 23 e0 zone regzone 1 4 1 5 zone t_r_a_f_f_i_c_i_s_o_prop__zn 1 3 2 3 Invalid configuration Member does not exist Invalid usage of broadcast zone To validate all zones in the zone database in the persistent storage defined configuration switch admin zone validate m 1 Defined configuration cfg t_r_a_f_f_i_c_i_s_o_c__fg bluezone greenzone cfg ticonfig regzone zone bluezone...

Page 1098: ...list to an existing TI zone switch admin zone add purplezone p 3 4 3 6 To add the option to disable failover for a TI zone switch admin zone add o n purplezone To add the option to enable failover for a TI zone switch admin zone add o f greenzone p 3 4 To remove portlist members from an existing TI zone switch admin zone remove bluezone p 3 4 3 6 To activate the TI zone bluezone switch admin zone ...

Page 1099: ...guration TI Zone Name ti_red Port List 4 4 5 5 3 3 Configured Status Activated Failover Disabled Enabled Status Deactivated To display members for the zone ti_red in ascending order switch admin zone show ti_red ascending Defined TI zone configuration TI Zone Name ti_red Port List 3 3 4 4 5 5 Configured Status Activated Failover Disabled Enabled Status Deactivated To create an FCR TI zone within a...

Page 1100: ... support The base zone object red_______base The RD zone configuration r_e_d_i_r_c__fg To display the newly created zone objects switch admin cfgshow Defined configuration cfg myHTcfg myHostTarget cfg r_e_d_i_r_c__fg red_______base red_0917_00_3f_3f_3f_23_24_25_26_3f_3f_3f_30_32_00_00_00 zone myHostTarget 00 3f 3f 3f 23 24 25 26 3f 3f 3f 30 32 00 00 00 zone red_0917_00_3f_3f_3f_23_24_25_26_3f_3f_3...

Page 1101: ... Fabric OS Commands and Appendix A Command Availability for details When an FCS policy is enabled this command can be issued only from the primary FCS switch OPERANDS The following operands are required zoneName Specify the name of an existing zone Double quotation marks are optional member Specify a member or list of members to be added The list must be enclosed in double quotation marks Members ...

Page 1102: ...lowed by any number of letters numbers or underscore characters Names are case sensitive For example Zone_1 and zone_1 indicate different zones Zone names are limited to 64 characters Spaces are ignored member Specify a member or a list of members to be included in the zone The list must be enclosed in double quotation marks Members must be separated by semicolons The list must have at least one m...

Page 1103: ...ted to switch 2 ports 12 and 14 and to the device with the world wide name 10 00 00 60 69 00 00 8a either node name or port name at the port in the fabric to which it is connected EXAMPLES To create three zones using a combination of port numbers and zone aliases switch admin zonecreate Purple_zone 1 0 switch admin zonecreate Blue_zone 1 1 array1 1 2 array2 switch admin zonecreate Green_zone 1 0 1...

Page 1104: ...configuration with the cfgEnable command NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details When an FCS policy is enabled this command can be issued only from the primary FCS switch OPERANDS The following operand is required zonename Specify th...

Page 1105: ...ons cfgcreate Create a zone configuration cfgdelete Delete a zone configuration cfgdisable Disable a zone configuration cfgenable Enable a zone configuration cfgremove Remove a member from a configuration cfgsave Save zone configurations in flash cfgshow Print zone configuration information cfgsize Print size details of zone database cfgtransabort Abort zone configuration transaction cfgtransshow ...

Page 1106: ...strictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS The following operands are required objectName The name of the object that you want to copy Quotation marks are optional newName The name of the object that you want created Quotation marks are optional A zone configuration name must begin with a letter followed by a...

Page 1107: ...from the primary FCS switch The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS This command has the following operand objectName The name of the object that you want to expunge Quotation marks are optional This operand is required EXAMPLES T...

Page 1108: ...ge 22 21 00 00 20 37 0c 71 02 alias array2 21 00 00 20 37 0c 76 22 21 00 00 20 37 0c 76 28 alias loop1 21 00 00 20 37 0c 76 85 21 00 00 20 37 0c 71 df SEE ALSO cfgAdd cfgClear cfgDelete cfgDisable cfgEnable cfgRemove cfgSave cfgShow zoneObjectCopy zoneObjectRename ...

Page 1109: ...n restrictions that may be in place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details OPERANDS The following operands are required objectName The name of the object you want to rename newName The new name of the object A zone configuration name must begin with a letter that can be followed by any number of letters numbers and underscores Names are case sen...

Page 1110: ...n place Refer to Chapter 1 Using Fabric OS Commands and Appendix A Command Availability for details When an FCS policy is enabled this command can be issued only from the primary FCS switch OPERANDS The following operands are required zonename Specify the name of the zone from which to remove a member Double quotation marks are optional zoneMemberList Specify a member or a list of members to be re...

Page 1111: ... Availability for details When FCS policy is enabled this command can be issued on any FCS switch in the fabric OPERANDS This command has the following operands sort Displays D I zone members in ascending order pattern A POSIX style regular expression used to match zone configuration names This operand is optional Patterns can contain A question mark to match any single character An asterisk to ma...

Page 1112: ...splay the red zone only using pattern search switch admin zoneshow red zone red 3 4 1 2 4 5 2 3 To combine a pattern search with the sorting option switch admin zoneshow sort red zone red 1 2 2 3 3 4 4 5 To display the filtered content of the transaction buffer switch admin zoneshow red 1 zone red 3 4 1 2 4 5 2 3 To display the filtered and sorted content of the transaction buffer switch admin zon...

Page 1113: ...cfgCreate Must be run from the primary FCS switch cfgDelete Must be run from the primary FCS switch cfgDisable Must be run from the primary FCS switch cfgEnable Must be run from the primary FCS switch cfgRemove Must be run from the primary FCS switch cfgSave Must be run from the primary FCS switch cfgShow Can be run on all FCS switches cfgSize Must be run from the primary FCS switch cfgTransAbort ...

Page 1114: ...ove Must be run from the primary FCS switch secPolicyRemove Must be run from the primary FCS switch secPolicySave Must be run from the primary FCS switch secPolicyShow Can be run on all FCS switches snmpConfig Can be run on all FCS switches tsClockServer Can be run on all switches to view the NTP server s IP address You can only modify the NTP server s IP address on the primary FCS switch zoneAdd ...

Page 1115: ...ve OM observe modify N none not available 3 Admin Domain availability If Admin Domains are enabled the system checks that the command is allowed in the currently selected Admin Domain For information on Admin Domain concepts and restrictions refer to the Fabric OS Administrator s Guide Admin Domain Types are one or more of the following If more than one AD type is listed for a command the AD type ...

Page 1116: ...nd is supported on the platform for which it is targeted Encryption commands and permissions There are two system RBAC roles that are permitted to perform Encryption operations 1 Admin and SecurityAdmin Users authenticated with the Admin and SecurityAdmin RBAC roles may perform cryptographic functions assigned to the FIPS Crypto Officer including the following Perform encryption node initializatio...

Page 1117: ... OM N O Disallowed VF DS delete decommissionedkeyids N OM N N N OM N O Disallowed VF DS deleteencgroup N OM N N N O N OM Disallowed VF DS deletefile N OM N N N O N OM Disallowed VF DS deletehacluster N OM N N N OM N O Disallowed VF DS deletetapepool N OM N N N OM N O Disallowed VF DS deregauthcard N OM N N N O N OM Disallowed VF DS dereggroupleader N OM N N N O N OM Disallowed VF DS deregkeyvault ...

Page 1118: ...llowed VF DS regKACcert N OM N N N O N OM Disallowed VF DS regKaClogin N OM N N N O N OM Disallowed VF DS regkeyvault N OM N N N O N OM Disallowed VF DS regmembernode N OM N N N O N OM Disallowed VF DS removehaclustermember N OM N N N OM N O Disallowed VF DS removeinitiator N OM N N N OM N O Disallowed VF DS removeLUN N OM N N N OM N O Disallowed VF DS replace N OM N N N OM N O Disallowed VF DS re...

Page 1119: ... ag O OM OM OM O O O N N A Allowed SwitchMember VF All agAutoMapBalance O OM OM OM O O O N N A Allowed SwitchMember VF All agShow O OM OM OM O O O N Allowed VF All aliAdd O OM O O OM OM O O Allowed VF All aliCreate O OM O O OM OM O O Allowed VF All aliDelete O OM O O OM OM O O Allowed VF All aliRemove O OM O O OM OM O O Allowed VF All aliShow O OM O O OM OM O O Allowed VF All aptPolicy O OM O O N ...

Page 1120: ...l cfgDelete O OM O O OM OM O O Allowed VF All cfgDisable O OM O O OM OM O O Allowed VF All cfgEnable O OM O O OM OM O O Allowed VF All cfgRemove O OM O O OM OM O O Allowed VF All cfgSave O OM O O OM OM O O Allowed VF All cfgShow O OM O O OM OM O O Allowed VF All cfgSize O OM O O OM OM O O Allowed VF All cfgTransAbort O OM O O OM OM O O Allowed VF All cfgTransShow O OM O O OM OM O O Allowed VF All ...

Page 1121: ...ed N A diagPost O OM OM OM N OM O N SwitchMember CH N A diagRetry O OM OM OM N OM O N SwitchMember CH N A diagShow O OM OM OM N OM O N SwitchMember VF All distribute N OM N N N OM N OM AD0 Disallowed VF All dlsReset O OM O O N OM O N SwitchMember VF All dlsSet O OM O O N OM O N SwitchMember VF All dlsShow O OM O O N OM O N SwitchMember VF All dnsConfig O OM OM OM O OM O OM SwitchMember CH N A encl...

Page 1122: ...VF All fcpLogClear O OM OM OM N OM O N SwitchMember VF All fcpLogDisable O OM OM OM N OM O N SwitchMember VF All fcpLogEnable O OM OM OM N OM O N SwitchMember VF All fcpLogShow O OM OM OM N OM O N SwitchMember VF All fcpProbeShow O OM OM OM N OM O N Allowed VF All fcpRlsShow O OM OM OM N OM O N Allowed VF All fcrBcastConfig O OM O O O OM O O SwitchMember VF BS fcrChipTest O OM OM OM N OM O N Switc...

Page 1123: ...CH N A firmwareDownload O OM OM OM O OM O OM SwitchMember CH N A firmwareDownloadStatus O OM OM OM O OM O OM SwitchMember CH N A firmwareKeyShow O OM O O O O O OM SwitchMember CH N A firmwareRestore O OM OM OM O OM O O SwitchMember CH N A firmwareShow O OM OM OM O OM O O Allowed VF N A fmMonitor O OM OM OM N OM O N SwitchMember VF All foscConfig O OM OM OM O OM O OM Allowed SwitchMember Disallowed...

Page 1124: ...llowed CH N A historyMode O OM OM OM N OM O N Allowed SwitchMember CH N A historyShow O OM OM OM N OM O N Allowed CH N A httpcfgShow O OM OM OM N OM O N Allowed VF All i O O O O O O O O SwitchMember CH N A iclCfg O OM OM OM O OM OM O SwitchMember CH N A ifModeSet O OM O OM N OM O N SwitchMember CH N A ifModeShow O OM O OM N OM O N Allowed CH N A interfaceShow O OM OM OM O OM O N Allowed VF All iod...

Page 1125: ...pabilityShow O OM OM OM O OM O N Allowed VF All msConfigure O OM OM OM O OM O N SwitchMember VF All msPlatShow O OM OM OM O OM O N Allowed VF All msPlatShowDBCB O OM OM OM O OM O N Allowed VF All msPlClearDB O OM OM OM O OM O N Disallowed VF All msPlMgmtActivate O OM OM OM O OM O N Disallowed VF All msPlMgmtDeactivate O OM OM OM O OM O N Disallowed VF All msTdDisable O OM OM OM O OM O N Disallowed...

Page 1126: ...ortEEMask O OM O OM N OM O N SwitchMember VF All perfShowAlpaCrc O OM O OM N OM O N PortMember VF All perfShowPortEEMask O OM O OM N OM O N PortMember VF All perfTTmon O OM O OM N OM O N SwitchMember VF All ping ping6 O OM O OM N OM O N Allowed CH N A policy O OM OM OM O OM OM O SwitchMember VF All portAddress O OM OM OM O OM OM O SwitchMember VF All portAlpaShow O OM OM OM N OM O N PortMember VF ...

Page 1127: ...ber VF All portCfgOctetSpeedCombo O OM OM OM O OM OM O Allowed VF ALL portCfgPersistentDisable O OM OM OM O OM OM O Allowed PortMember VF All portCfgPersistentEnable O OM OM OM O OM OM O Allowed PortMember VF All portCfgQos O OM OM OM O OM OM O PortMember VF All portCfgShow O OM OM OM O OM OM O PortMember VF All portCfgSpeed O OM OM OM O OM OM O PortMember VF All portCfgTrunkPort O OM OM OM O OM O...

Page 1128: ...ypeEnable O OM OM OM O OM O OM SwitchMember VF All portLoopbackTest O OM OM OM N OM O N SwitchMember CH N A portMirror N OM N N N N N N PortMember VF All portName O OM OM OM O OM OM O PortMember VF All portPerfShow O OM OM OM N OM O N Allowed VF All portRouteShow O OM OM OM O OM O N PortMember VF All portShow O OM OM OM O OM OM O PortMember VF All portStats64Show O OM OM OM N OM O N PortMember VF ...

Page 1129: ...ete O OM N O N OM O OM AD0 Disallowed VF All secPolicyDump O OM N O N OM O OM AD0 Disallowed VF All secPolicyFCSMove O OM N O N OM O OM AD0 Disallowed VF All secPolicyRemove O OM N O N OM O OM AD0 Disallowed VF All secPolicySave O OM N O N OM O OM AD0 Disallowed VF All secPolicyShow O OM N O N OM O OM Allowed AD0 Disallowed VF All secStatsReset O OM N O N OM O OM AD0 Disallowed VF All secStatsShow...

Page 1130: ...Beacon O OM OM OM O OM O O SwitchMember VF All switchCfgPersistentDisable O OM OM OM O OM O O SwitchMember VF All switchCfgPersistentEnable O OM OM OM O OM O O SwitchMember VF All switchCfgSpeed O OM OM OM O OM OM O SwitchMember VF All switchCfgTrunk O OM OM OM O OM OM O SwitchMember VF All switchDisable O OM OM OM O OM O O SwitchMember VF All switchEnable O OM OM OM O OM O O SwitchMember VF All s...

Page 1131: ...O OM OM OM O OM O OM SwitchMember Allowed CH N A tsTimeZone O OM OM OM O OM O OM SwitchMember CH N A turboRamTest O OM OM OM N OM O N SwitchMember CH N A uptTme O O O O O O O O Allowed CH N A uRouteConfig O OM OM OM O OM O N SwitchMember VF All uRouteRemove O OM OM OM O OM O N SwitchMember VF All uRouteShow O OM OM OM O OM O N Allowed VF All usbStorage N OM N N N N N OM Allowed CH N A userConfig f...

Page 1132: ... All zoneObjectExpunge O OM O O OM OM O O Allowed VF All zoneObjectRename O OM O O OM OM O O Allowed VF All zoneRemove O OM O O OM OM O O Allowed VF All zoneShow O OM O O OM OM O O Allowed VF All TABLE 8 Fabric OS command RBAC availability and admin domain type Continued Command Name User Admin Oper Sw Admin Zone Admin Fabric Admin BS Admin Sec Admin Admin Domain Context Switch Type ...

Reviews: