![Brocade Communications Systems Brocade 8/12c Command Reference Manual Download Page 250](http://html1.mh-extra.com/html/brocade-communications-systems/brocade-8-12c/brocade-8-12c_command-reference-manual_2817300250.webp)
216
Fabric OS Command Reference
53-1001764-01
diagClearError
22
diagClearError
Clears the diagnostics failure status.
SYNOPSIS
diagclearerror
[[
--slot
]
slot
]
-all
DESCRIPTION
Use this command to clear the diagnostics failure status. When used without operands, this command
clears all port failure flags.
NOTES
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
OPERANDS
This command has the following operand:
--slot
slot
Specify the slot on which to clear the diagnostics failure status. The default is set
to 0 and designed to operate on fixed-port-count products.
-all
If specified, all blades clear.
EXAMPLES
To clear the diag software flag:
switch:admin>
diagclearerror --slot 8
ERROR: DIAG CLEARERR
Diagnostics Errors Cleared, port: 8/31
Err# 0120041 081F
SEE ALSO
None