12 - TROUBLESHOOTING
All adjustments and repairs shall be made by an authorized Broaster Company representative.
ELECTRICAL TIPS
COMPLAINT
CAUSE
REMEDY
POWER light not illumi-
nated
1. Unit OFF
2. Main power OFF
3. Unplugged
4. Fire extinguisher pressure
below low limit
1. Press ON button
2. Turn ON
3. Plug in
4. Disconnect main power
Contact certified fire sup-
pression agent
Cycle will not start
1. Unit OFF
2. Main power OFF
3. Solid state controller in
program mode
4. Lockout Condition tripped
5. Platform not lowered
1. Press ON button
2. Turn ON
3. Exit program mode
4. See INDICATOR LIGHTS
below
5. Motor control failure
Contact service person
HEAT ON light not illumi-
nated
1. Unit OFF
2. Main power OFF
3. Solid state controller in
program mode
4. Oil temperature has
reached programmed
temperature
1. Press ON button
2. Turn ON
3. Exit program mode
4. Unit ready to cook
Cycle stops in progress
1. STOP button was pushed
2. Lockout Condition tripped
1. Press START button
2. See INDICATOR LIGHTS
below
Power Light illuminated but
no power to controller dis-
play
1. Lockout Condition tripped
1. See INDICATOR LIGHTS
below
12 - 1
Manual #16887 5/08 Rev 4/09
Summary of Contents for VF-2XP
Page 2: ......
Page 4: ......
Page 10: ......
Page 14: ...WIRING DIAGRAM VF 2 EXPORT CE 2 4 Manual 16887 5 08 NO NC C PRESSURE SENSOR P ...
Page 15: ...2 5 Manual 16887 5 08 WIRING DIAGRAM VF 3i EXPORT CE NO NC C PRESSURE SENSOR P ...
Page 21: ......
Page 31: ......
Page 33: ......
Page 37: ......
Page 39: ......