ELECTRICAL CHARACTERISTICS
The unit is available for 120/240 VAC or
120/208 VAC applied voltage, 30 amp,
60Hz, 1 phase electrical connection in the
USA and Canada. (4 wire with neutral and
ground)
•
When installed, the unit is to be field
wired and must be electrically grounded
in accordance with local codes, or in the
absence of local codes, with the National
Electrical Code, ANSI/NFPA 70, or the
Canadian Electrical Code, CSA C22.2,
as applicable.
ELECTRICAL CONNECTIONS
Applied voltage should match dataplate
listed voltage.
The electrical schematics can be found on
pages 4 thru 7 of this section.
2 - 3
Manual #16887 5/08
ELECTRICAL AMPERAGE RATING
Input
Voltage
VF2
Domestic
VF3i
Domestic
VF2
Export
VF3i
Export
VF2
CE
VF3i
CE
120/240
23
23
---
---
---
---
120/208
27
27
---
---
---
---
220
---
---
21
28
---
---
230
---
---
---
---
22
29