12 - 2
Manual #16887 5/08 Rev 4/09
INDICATOR LIGHTS
The series of indicator lights on the Display Panel check for specific conditions that make the
VF-2 fryer safe to operate. The unit will not start or continue a cook cycle if any of the following
indicator lights are lit.
Note:
Power to the controller and heating element are electronically disconnected when:
-
Access Door is Open
-
Air filter is not in place
-
Element is int he
UP
position
-
Grease filter is not in place
-
Air Flow is below acceptable level
-
High Limit Control has been tripped
(A)
The Product Door may be opened without interrupting the cooking cycle. However, cycle cannot
be started until product door is closed.
(B) Air Filter should be replaced at least every 3 months or sooner if volume is high.
COMPLAINT
CAUSE
REMEDY
Product Door
(A)
1. Product Door Open
2. Failed switch
1. Close product door
2. Push power OFF button
Contact service person
Access Door
1. Access Door Open
2. Failed switch
1. Close Access door
2. Push power OFF button
Contact service person
Element Up
1. Element in raised position
2. Failed switch
1. Lower element
2. Push power OFF button
Contact service person.
Air Flow
1. Fan failure
2. Failed switch
1. Push power OFF button
Contact service person
2. Push power OFF button
Contact service person
Air Filter
(B)
1. Air Filter not in place
2. Failed switch
1. Insert Air Filter all the way
2. Push power OFF button
Contact service person
Grease Filter
1. Grease Filter not in place
2. Failed switch
1. Insert Grease Filter
2. Push power OFF button
Contact service person
High Limit Reset
1. Oil exceeded maximum
temperature
2. Probe Failure
Push power OFF
Contact service person
Fire System
1. 6 months operation has
elapsed.
1. Contact certified Fire Ser-
vice Personnel for
required maintenance
inspection.
Summary of Contents for VF-2XP
Page 2: ......
Page 4: ......
Page 10: ......
Page 14: ...WIRING DIAGRAM VF 2 EXPORT CE 2 4 Manual 16887 5 08 NO NC C PRESSURE SENSOR P ...
Page 15: ...2 5 Manual 16887 5 08 WIRING DIAGRAM VF 3i EXPORT CE NO NC C PRESSURE SENSOR P ...
Page 21: ......
Page 31: ......
Page 33: ......
Page 37: ......
Page 39: ......