background image

Oil Conserving Fryer

 OCF30 

Electric Fryer 

Installation, Operation and Maintenance Manual 

This manual is updated as new information and models are released. Visit our website for the latest manual. 

 

 

 

 

 

 

 

 

 

 

 

 

 

Part Number: FRY_IOM_8196685   02/2018 

 

*8196685* 

FOR YOUR SAFETY 
Do Not Store or use gasoline or other 
flammable vapors and liquids in the vicinity 
of this or any other appliance. 

Original

 

Instructions

 

 

CAUTION

 

READ

 

THE

 

INSTRUCTIONS

 

BEFORE

 

USING

 

THE

 

FRYER.

 

 

 

Summary of Contents for Frymaster FPEL114C

Page 1: ...ormation and models are released Visit our website for the latest manual Part Number FRY_IOM_8196685 02 2018 8196685 FOR YOUR SAFETY Do Not Store or use gasoline or other flammable vapors and liquids...

Page 2: ...USTOMERS This equipment is to be installed in compliance with the basic plumbing code of the Building Officials and Code Administrators International Inc BOCA and the Food Service Sanitation Manual of...

Page 3: ...rovided to limit the movement of this appliance without depending on or transmitting stress to the electrical conduit A restraint kit is provided with the fryer If the restraint kit is missing contact...

Page 4: ...Up Procedures 3 2 3 2 Operation 3 2 3 3 Oil Attendant Automatic Topoff 3 3 3 3 1 Install the Oil Reservoir 3 3 3 3 2 Routine Oil Changes 3 3 3 3 3 Bulk Oil Systems 3 4 CHAPTER 4 Filtration Instruction...

Page 5: ...oting 6 2 6 2 1 Controller and Heating Problems 6 2 6 2 2 Error Message and Display Problems 6 2 6 2 3 Basket Lift Problems 6 3 6 2 4 Filtration Problems 6 4 6 2 5 Auto Top Off Problems 6 4 6 2 6 Erro...

Page 6: ...ter Fryers in this series come in full or split vat arrangements and can be purchased as two three or four vat fryers 1 2 Safety Information Before attempting to operate your unit read the instruction...

Page 7: ...ed by the Federal Communications Commission helpful How to Identify and Resolve Radio TV Interference Problems This booklet is available from the U S Government Printing Office Washington DC 20402 Sto...

Page 8: ...lled personnel before leaving the factory Frymaster does not assume responsibility for damage or loss incurred in transit The freight company assumes full responsibility for safe delivery upon accepta...

Page 9: ...upplied cords and plug assemblies must be hardwired using flexible conduit to the terminal block located on the rear of the fryer These fryers should be wired to NEC specifications Hardwired units mus...

Page 10: ...s open tank of hot oil being installed beside an open flame of any type including those of broilers and ranges In the event of a power failure the fryer s will automatically shut down If this occurs t...

Page 11: ...4 6 4 11 25 Single Phase Requirements MODEL VOLTAGE WIRE SERVICE MINIMUM WIRE SIZE AWG mm AMPS per leg FPEL14 208 2 3 5 83 68 FPEL14 240 2 4 5 19 59 FPEL14 480 2 8 3 26 30 NOTICE If this appliance is...

Page 12: ...mit the movement of this appliance without depending on or transmitting stress to the electrical conduit A restraint kit is provided with the fryer If the restraint kit is missing contact your local K...

Page 13: ...Controller 3000 Shown Filter Pan FootPrint Pro Built In Filtration Unit Power Switch Domestic Only Lift Rod FINDING YOUR WAY AROUND THE OCF30 SERIES ELECTRIC FRYER Filter Handle JIB reset button TYPIC...

Page 14: ...receptacle s Verify that the face of the plug is flush with the outlet plate with no portion of the prongs visible 3 Ensure that the power is switched on Some models are equipped with a master switch...

Page 15: ...he frypots not fill them The frypots will require manual filling upon startup and after disposal 3 3 1 Install the Oil Reservoir Remove the original lid from the oil container and foil liner Replace w...

Page 16: ...the cap and pour any remaining oil in the container into all fry vats equally see Figure 5 Figure 5 3 With the jug upright remove the cap and foil seal see Figure 6 Figure 6 4 Put the tube in the new...

Page 17: ...efer to Section 4 1 2 for instructions on preparing the Magnasol Filter configuration for use Operation of all three configurations is the same and is covered in section 4 3 Disassembly and reassembly...

Page 18: ...Assembly 1 Pull the filter pan out from the cabinet and remove the crumb tray and Magnasol filter assembly see Figure 5 Clean as directed in section 4 4 The pan cover must not be removed except for c...

Page 19: ...s handling The oil to be filtered is at or near 350 F 177 C Ensure drain handles are in their proper position before operating any switches or valves Wear all appropriate safety equipment when drainin...

Page 20: ...back up to and through the frypot during a filter 6 After the oil is filtered close the drain valve when prompted and allow the fryer to refill Let the filter pump run 10 to 12 seconds after the oil...

Page 21: ...dislodge shortening will distort the strip adversely affecting its fit It is designed for a tight fit and should only be removed for cleaning 4 3 Disassembly and Reassembly of the Magnasol Filter Dis...

Page 22: ...positioned in frame Step 4 Connect corner then pivot frame over free edges of screens Handle 4 4 Draining and Disposing of Waste Oil When cooking oil is exhausted the oil must be drained into the filt...

Page 23: ...ith a sealable cover under the drainpipe The METAL container must be able to withstand the heat of the oil and hold hot liquids 3 Follow the instructions for disposing of oil on page 1 13 of the 3000...

Page 24: ...lar attention must be paid to the concentration of cleaner and the length of time the cleaner remains on the food contact surfaces 5 2 DAILY CHECKS AND SERVICE 5 2 1 Inspect Fryer and Accessories for...

Page 25: ...will form on the inside of the frypot This film should be periodically removed by following the boil out procedure that follows 1 Before switching the fryer s ON close the frypot drain valve s then fi...

Page 26: ...ct or dashed lines indicating that the frypot contents are within the cooking range press the switch once to display the temperature and setpoint of the cooking oil as sensed by the temperature probe...

Page 27: ...cleanliness If there is a large accumulation of crumbs in the crumb basket advise the owner operator that the crumb basket should be emptied into a fireproof container and cleaned daily Verify that a...

Page 28: ...to ensure that it doesn t happen again If a controller malfunctions because of a poor connection check all other connections too If a fuse continues to blow find out why Always keep in mind that failu...

Page 29: ...re other components have failed A Verify that all power cords are fully seated in the receptacles locked into place and that a circuit breaker is not tripped B Close drain C Call your FAS for assistan...

Page 30: ...failure A Open drain valve B Failed high limit A Close the drain valve B Shut the fryer down immediately and call your FAS for assistance Controller displays TEMP PROBE FAILURE or PROB Problem with th...

Page 31: ...your FAS for assistance Filter Pump runs but oil return is very slow Improperly installed or prepared filter pan components or cold oil Remove the oil from the filter pan and replace the filter paper...

Page 32: ...removed during update E21 CHANGE FILTER PAPER 25 hour timer has expired Change filter paper and follow prompts E22 OIL IN PAN ERROR Oil may be present in the filter pan E25 RECOVERY FAULT Recovery ti...

Page 33: ...happens once the temperature reaches 423 F to 447 F 217 C to 231 C for non CE high limits and 405 F to 426 F 207 C to 219 C for CE high limits Once the high limit opens the computer displays HELP HI 2...

Page 34: ...shown in figure 3 5 Position the oil reservoir in the melter sliding the oil pickup tube into the female receptacle Position the front lid and the front of the melter See figure 4 NOTE A separate harn...

Page 35: ...eset the top off system DO NOT ADD hot oil to the shortening melter The temperature of the oil reservoir should not exceed 140 F 60 C Add small amounts of solid shortening to the reservoir to ensure i...

Page 36: ...oil is pumped from the tanks thru the fitting located on the top to the fryer see Figure 1 The 4 pin wire harness allows connection to various bulk oil systems see Figure 2 Connect pins 1 and 4 to the...

Page 37: ...al operation NOTE It takes approximately 10 seconds from the time the button is pressed until the fresh oil pump starts It may take up to 15 seconds before the level in the JIB begins to rise It takes...

Page 38: ...e drain valve is closed 2 At the rocker panel switch to Bulk Mode 3 Open the return valve on the empty tank Press the Add Fresh Oil button Fill to the lower line in the frypot 4 Close the return valve...

Page 39: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Page 40: ..._IOM_8196685 02 2018 8197423 WWW WELBILT COM Welbilt provides the world s top chefs and premier chain operators or growing independents with industry leading equipment and solutions Our cutting edge d...