SS 16.16 Installation and Operation Manual
INSTALLATION
“Open Collector” Status Outputs, 16 Port Output Control
The SS 16.16 provides 16 open collector status outputs. The status outputs may be
configured to operate in one of three modes:
1. The status output follows the associated channel. SW1-6 OFF.
2. The status outputs a one-second pulse when the associated channel is select-
ed. SW1-6 ON.
3. SW1-8 OFF enables SW1-6. SW1-8 ON disables SW1-6 and allows soft-
ware control.
“PIP” with Programmable Pulse Stretcher:
PIP is always active. Minimum input pulse width must be 50ms. The
Programmable Pulse Stretcher (PIP) provides 16 “PIP” (GPI) inputs. The
Programmable Pulse Stretcher Duration may be globally set from none to 2.55
seconds.
NOTE: When the unit ID is set to 0, no polling of the “PIP” (GPI) inputs is
required.